Sentry Voyager 12V 60A Installation & Operation Manual

Manual is about: Marine Battery Chargers

Summary of Voyager 12V 60A

  • Page 1

    Marine battery chargers voyager elite series installation/ operation linear devices corporation dba sentry 11126 air park rd, suite g ashland, va 23005 december 2017 www.Sentrychargers.Com phone: 804-368-8428 fax: 804-368-8438.

  • Page 2: Table Of Contents

    2 table of contents safety precautions 3-4 serial number 4 model number 5 general instructions 5 installation instructions 6 connection details 7-9 ac cables and circuit breaker sizing 10 dc cables and fuses 11-12 setting charging curve and battery types 12-15 operation of battery temp sensor 16 led...

  • Page 3: Safety Precautions

    3 safety precautions to prevent any risk of electric shock or fire, read this manual carefully before installing the equipment. This equipment is not designed for use by people (including children) with diminished physical, sensory or mental capacities, or people without experience or knowledge of s...

  • Page 4

    4 correctly attached to the housing (using the nut provided), in the hole designed for this purpose. For safety reasons, the device’s earth ground terminal(pe “protective earth” terminal), must be connected to the system’s physical earth ground (yellow & green wire of the main power). Refer to the w...

  • Page 5: General Instructions

    5 curve no. 9 is compatible with a lifeso4 battery provided that the battery is equipped with bms-type battery protection (battery management system) within the actual battery. In this case, refer to the battery manufacturer’s recommendations for the choice of charging cycle. General instructions ma...

  • Page 6: Installation Instructions

    6 on the housing prior to connection). The battery temperature sensor(24v100a version only) verify verify the product’s data plate label, attached to one side of the product, to ensure that the technical details actually meet your needs (main supply voltage, charger capacity, etc.). Installation ins...

  • Page 7: Connection Details

    7 connection details.

  • Page 8

    8 marking description l1 ac main, 8 awg (10mm2) max (wire color code: brown or black) n/l2 ac neutral or l2, 8 awg (10mm2) max (wire color code: blue, white or red) pe (ground) ac ground, 8 awg (10mm2) max (wire color code: green & yellow or green) -dc battery negative (common), pin m8 (wire color c...

  • Page 9: Batteries

    9 example of connection on the basis of 3 distinct sets of batteries important check for proper torque and crimp of connections and terminals..

  • Page 10: Ac Wiring

    10 ac cables and circuit breaker sizing ac wiring check the quality of connections and proper tightening of connections. For main power, preferably use a ho7rnf-type industrial cable. Ensure that you comply with the following recommendations. Charger 220-240v ac 50/60hz 100-120v ac 60hz capacity len...

  • Page 11: Dc Cables And Fuses

    11 dc cables and fuses dc wiring check the quality of connections and proper tightening of connections. Battery cables must be as direct and short as possible. Each battery output can provide the charger’s full amperage and all the cables must have identical cross-sections. Ensure that you comply wi...

  • Page 12: Dc Fuses

    12 dc fuses when maintaining the charger’s internal fuses, these must be replaced by fuses with strictly identical characteristics and performance levels. Risks of irreversible damage to the equipment. It is essential and highly recommended that you install, as close as possible to each positive out...

  • Page 13: Caution

    13 the performance and usable life of batteries are thereby maximized. By virtue of fully automated charging cycles, the batteries are protected against surges, providing a permanent connection for the charger. Selection of the charging program takes place on installation using the “charge select” d...

  • Page 14: Charger Curve Settings

    14 charger curve settings curve bat type phase 12v 24v 0 open v. Boost 14.4v 28.8v lead v. Float 13.2v 26.4v 1 sealed v. Boost 14.2v 28.4v lead v. Float 13.6v 27.2v 2 lead v. Boost 14.8v 29.6v calcium v. Float 13.8v 27.6v 3 «delphi» v. Boost 15.4v 30.8v type v. Float 13.8v 27.6v charge curve «op- v....

  • Page 15

    15 winter 6 v. Boost 14.2v 28.4v sealed v. Float 13.6v 27.2v lead charge curve 7 gel & v. Boost 14.4v 28.8v agm v. Float 13.8v 27.6v charge curve 8 power v. Float 13.6v 27.2v supply charge curve lifeso4 9 + inte- v. Float 14.4v 28.8v grated bms charge curve.

  • Page 16

    16 operation of battery temperature sensor the temperature sensor allows the charging voltage to be automatically adjusted depending on the battery and ambient temperature. This function increases battery life, by reducing output voltage and current due to high ambient and/or battery temperature. Th...

  • Page 17: Led Display

    17 led display the voyager elite charger is equipped with a local multifunction led display, which, among other things, shows the details of the key stages of the battery charging process. Boost phase: the battery is in its rechargingphase, reaching a level of charge of close to 80%. This recharging...

  • Page 18

    18 mode and display operation mode description solid led flashing led charger powered all leds on and/or chan- initialization for 3 - ge of charging cycle seconds batteries in power on boost charging phase - phase (charge from 0 to boost 80%) batteries in power on charging phase - absorption/ equali...

  • Page 19

    19 mode description solid led flashing led excessive battery temperature fault battery automatic restart temperature after a min delay - temp fault for 30 seconds, subject to disappearance of the fault external tempera- ture sensor fault battery automatic restart temp sensor after a min delay - faul...

  • Page 20: Technical Specifications

    20 technical specifications 12v 60a 12v 90a 24v 40a 24v 60a 24v 100a main power characteristics main 100v-120v 60hz and/or 220-240v 50/60hz 220-240v voltage (+/-15%) (+/-15%) power typically 0.9 factor output typically 83% typically 87% inrush current current 12a/5a 16a/7a 14a/6a 15a/9a 15a draw act...

  • Page 21

    21 12v 60a 12v 90a 24v 40a 24v 60a 24v 100a winter off season v.Boost = 14.2v v.Boost = 28.4v sealed v.Float = 13.6v v.Float = 27.2v lead gel & v.Boost = 14.4v v.Boost = 28.8v agm v.Float = 13.8v v.Float = 27.6v power v.Float = 13.6v v.Float = 27.2v supply lifeso4 + integra- v.Float = 14.4v v.Float ...

  • Page 22

    22 12v 60a - 12v 90a 24v 100a 24v 40a - 24v 60a hs “shutdown” type with automatic restart temperature once the fault has disappeared sensor general main supply main fuse fault general battery supply output fuses on –dc supply fault circuit board conformal coated protection on circuit board operating...

  • Page 23: Dimensions

    23 dimensions 12v 60a 12v 90a 24v 40a 24v 60a 24v 100a height a 14.2 inch (360 mm) width b 13.4 inch (340 mm) depth c 4.9 inch (125 mm) (190 mm) 7.5 inch.

  • Page 24: Warranty

    24 warranty to prevent any risk of incorrect use of the charger, carefully read the list of potential sceniros or faults not covered by the product warranty this device is not protected against batterypolarity reversals. Risk of irreversible damage to the equipment. Should the device be dropped, thi...