1.3 Positioning the Cabinet
Power Supply
The cooler is supplied with a 1.8m flexible power cord fitted with a
3-pin plug, which exits out the rear of the refrigeration unit.
Ventilation
Ensure adequate ventilation is provided around the cooler. The
cooler should not be recessed or enclosed in a cabinet. It is
designed for free-standing installation only. The recommended
clearance on both sides and at the back of the cabinet is 50mm. The
maximum normal operating conditions are:
Location
When positioning the cabinet:
•
Avoid direct sunlight and warm draughts etc.
•
Allow adequate space for the door to open fully.
•
Ensure the cabinet is positioned on a level surface so the door
shuts and seals correctly, and to prevent the condensate tray
from overflowing.
Levelling
This cooler has a stabiliser foot located underneath the door hinge.
After final positioning, the stabiliser foot should be screwed firmly
down to floor level to stabilise the cabinet. Turn the stabiliser foot
clockwise to raise the cabinet or anti-clockwise to lower the cabinet.
Model
Operating Conditions
Climatic Class
HB80
40°C at 40% RH
5
HB110
30°C at 55% RH
4