Serene SC112G User Manual

Manual is about: Four Glass Sided Chiller

Summary of SC112G

  • Page 1

    User manual man10555 r ev . 5.0 o ct. 2016 sc112g serene four glass sided chiller type: hsc112a/z089 from skope.

  • Page 2

    Sc112g serene four glass sided chiller type: hsc112a/z089 user manual man10555 rev. 5.0 oct. 2015 © 2012 skope industries limited. All rights reserved. Skope industries limited reserve the right to alter specifications without notice. Is a registered trademark of skope industries limited. Skope indu...

  • Page 3

    Serene sc112g user manual iii contents 1 installation safety first . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 positioning the chiller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 climate class . . . . . . . . . . . . . . . . ...

  • Page 4

    4 installation user manual serene sc112g 1 installation safety first always observe safety precautions when using any electrical appliance. Read these instructions carefully and retain them for future reference. When the appliance is used by or near young children or infirm persons, close supervisio...

  • Page 5

    5 serene sc112g installation user manual positioning the chiller climate class the chiller is designed to operate within a climate class 3 environment (25°c @ 60% rh). Location select a suitable location for the chiller away from direct sunlight and heat sources e.G. Radiators, baseboard heaters, co...

  • Page 6

    6 operation user manual serene sc112g 2 operation automatic start-up after the chiller has been positioned in a suitable place, plug it in and check the following activity. Loading product let the chiller run for 30 minutes before loading it with product the first time. When loading the cabinet shel...

  • Page 7

    7 serene sc112g operation user manual electronic controller introduction the electronic controller is visible through a cut-out in the front panel. It uses temperature probes and a door switch to collect data and runs the chiller accordingly. The electronic controller can be manually switched betwee...

  • Page 8

    8 operation user manual serene sc112g normal and energy saving modes the electronic controller can be switched between two operating modes: ‘normal’ mode and ‘energy saving’ mode. When in normal mode, the interior lights are on and the internal temperature is regulated to the setpoint setting (see p...

  • Page 9

    9 serene sc112g operation user manual temperature setpoint the chiller temperature setpoint is factory set at 2°c for storage of perishable products (all shelves maintain temperatures below 5°c). The cabinet setpoint can be adjusted between 0°c and 4°c. Skope do not recommend that the setpoint be ch...

  • Page 10

    10 maintenance user manual serene sc112g 3 maintenance cleaning many commercially available cleaning products contain solvents that may damage the plastic components of the chiller and cause them to crack. Do not use abrasive or corrosive cleaners or boiling water. Wash with warm water and wipe down...

  • Page 11

    11 serene sc112g maintenance user manual troubleshooting for problems with the chiller refer to the following table. Problem possible cause suggestions • chiller not operating. • loss of power supply. • check mains power supply. • interior lights not on. • electronic controller displays eco indicati...

  • Page 12

    Skope contacts skope industries limited new zealand contact head office po box 1091, christchurch new zealand freephone: 0800 947 5673 fax: (03) 983 3896 e-mail: enquiry@skope.Co.Nz website: www.Skope.Co.Nz australian contact a.B.N. 73 374 418 306 po box 7543, baulkham hills b.C. Nsw 2153, australia...