SmartBridges airPoint XO Quick Install Manual - 3. Hardware Installation
airPoint XO Series
Page 7 of 24
3. Hardware Installation
For airPoint XO™ and airPoint XO
2
™
•
Connect an outdoor rated shielded Ethernet CAT 5 / 5e cable to
the RJ45 connector of the airPoint XO™ ( Located inside the
weather proof connector ) to the ETH OUT of PoE Outdoor™
(Refer to the PoE Outdoor™ user guide for detailed instructions)
•
Connect the ETH IN RJ45 connector of the PoE Outdoor™ to the
ETH Out of the Wall Plate Unit with proper CAT 5 / 5e cable .
•
Connect the ETH in of the Wall plate to the LAN port of the
PC or network through CAT 5 / 5e cable
•
Connect the DC output ( RJ 11 Plug ) of the AC adapter to the
PWR in of the Wall plate unit
•
Confirm that the AC input to the AC adaptor is 110V AC (+/-5%),
60Hz in US and 240V AC (+/-5%), 50 HZ in EU. Make sure the AC
input is clean of any surges or spikes. It is recommended to use a
use a Spike and a surge suppressor, buster or a UPS to make sure
that the power supply is clean. The UPS or buster should be of the
correct voltage and current rating. Make sure that the AC supply
has a proper Ground available to the surge suppressor, spike
protector or UPS.
•
Use only smartBridges Power over Ethernet Outdoor™ with a 48V
AC adaptor.
•
The specification for smartBridges AC adaptor :
Current Ratings 570 mA @ 48V
Type of Plug RJ 11 4p4c
Plug Polarity Pins 1, 2 Positive
Pins 3, 4 Negative
AC Input 90 ~ 267 V AC 40 ~ 60 Hz
•
Connect the AC Adapter to the mains outlet.