    Hgm6110/6120 automatic generator module operating manual smartgen electronics.

  • Page 2

    Smartgen electronic equipment co,.Ltd no.12 dongqing street zhengzhou henan province p.R.China tel : (0086)-371-67992951 67991572 fax: (0086)-371-67992952 web: http://www.Smartgen.Com.Cn http://www.Smartgen.Cn email: smartgen@smartgen.Com.Cn all rights reserved. No part of this publication may be re...

  • Page 3: Content

    Hgm6110/6120 auto start module hgm6110/6120 auto start module issue 2.0 2008-10-27 page 3 of 24 content 1.Summary .....................................................................................4 2.Performance and characteristics .................................4 3.Specification..................

  • Page 4: 1.  Summary

    Hgm6110/6120 auto start module hgm6110/6120 auto start module issue 2.0 2008-10-27 page 4 of 24 1. Summary hgm6100 series generator controller integrating digital, intelligent and network techniques is used for automatic control system of diesel generator. It can carry out functions including automa...

  • Page 5

    Hgm6110/6120 auto start module hgm6110/6120 auto start module issue 2.0 2008-10-27 page 5 of 24 system input; control protection: automatic start/stop, load transfer and alarming of ◆ generator; parameters setting: allow user to modify setting and store them inside internal ◆ flash memory, the param...

  • Page 6: 3.  Specification

    Hgm6110/6120 auto start module hgm6110/6120 auto start module issue 2.0 2008-10-27 page 6 of 24 3. Specification operating voltage dc8. 0v to 35. 0v, continuous power supply power consumption alternator input range 3-phase 4 wire 2-phase 3 wire single phase 2 wire 15v ac - 360 v ac (ph-n) 15v ac - 3...

  • Page 7: 4.2  Automatic Operation

    Hgm6110/6120 auto start module hgm6110/6120 auto start module issue 2.0 2008-10-27 page 7 of 24 manual test mode pressing this key will set the module into manual test mode., when generate electricity is normal, the generator will on-load(hgm6110 have not this key) set/enter enter the set menu, or v...

  • Page 8: 4.3  Manual Operation

    Hgm6110/6120 auto start module hgm6110/6120 auto start module issue 2.0 2008-10-27 page 8 of 24 after the starter motor has disengaged, the safety on timer is activated, allowing oil pressure, high engine temperature, under-speed, charge fail and any delayed auxiliary fault inputs to stabilize witho...

  • Page 9: 5.  Protection

    Hgm6110/6120 auto start module hgm6110/6120 auto start module issue 2.0 2008-10-27 page 9 of 24 after the starter motor has disengaged, the safety on timer is activated, allowing oil pressure, high engine temperature, under-speed, charge fail and any delayed auxiliary fault inputs to stabilize witho...

  • Page 10: 5.2  Shutdown Alarm

    Hgm6110/6120 auto start module hgm6110/6120 auto start module issue 2.0 2008-10-27 page 10 of 24 fallen below the low oil pressure setting level after the safety on timer has expired and the input of inhibit opl stop is activated, a warning will occur. Loss of speed signal, if the speed sensing sign...

  • Page 11

    Hgm6110/6120 auto start module hgm6110/6120 auto start module issue 2.0 2008-10-27 page 11 of 24 low oil pressure, if the module detects that the engine oil pressure has fallen below the low oil pressure setting level after the safety on timer has expired, a shutdown will occur. Overspeed, if the en...

  • Page 12: 6.  Connecting Terminal

    Hgm6110/6120 auto start module hgm6110/6120 auto start module issue 2.0 2008-10-27 page 12 of 24 6. Connecting terminal pin function dim description 1 dc plant supply input (-ve) 2. 5mm system dc negative input. (battery negative). 2 dc plant supply input (+ve) 2. 5mm system dc positive input. (batt...

  • Page 13

    Hgm6110/6120 auto start module hgm6110/6120 auto start module issue 2.0 2008-10-27 page 13 of 24 pin function dim description 17 coolant temperature input connect to coolant temperature sender 18 oil pressure input connect to oil pressure sender 19 fuel level input connect to fuel level sender refer...

  • Page 14

    Hgm6110/6120 auto start module hgm6110/6120 auto start module issue 2.0 2008-10-27 page 14 of 24 7. Parameter range and define all parameters of hgm6100 as follows: 7.1 parameters table (table 1) num parameter range default remark 1 mains normal delay (0-3600)s 10 2 mains abnormal delay (0-3600)s 5 ...

  • Page 15

    Hgm6110/6120 auto start module hgm6110/6120 auto start module issue 2.0 2008-10-27 page 15 of 24 num parameter range default remark 22 gens over volt (30-360)v 264 when generator voltage is over than the point, generator over voltage is active. When the point is 360v, generator over voltage is disab...

  • Page 16

    Hgm6110/6120 auto start module hgm6110/6120 auto start module issue 2.0 2008-10-27 page 16 of 24 num parameter range default remark 31 lost speed delay 0-20.0s 5.0 when speed is zero and remain for the delay, send out shutdown alarm. When the delay is zero, send out warning alarm. 32 charge fail vol...

  • Page 17

    Hgm6110/6120 auto start module hgm6110/6120 auto start module issue 2.0 2008-10-27 page 17 of 24 num parameter range default remark 51 op disconnect (0-400)kpa 200 when engine oil pressure is large than this point, starter will disconnect. 52 select ac system 0 3p4l 1 2p3l 2 1p2l 0 3p4l(3 phase 4 wi...

  • Page 18: 7.4  Sensor (Table 4)

    Hgm6110/6120 auto start module hgm6110/6120 auto start module issue 2.0 2008-10-27 page 18 of 24 num content description 1 high temp input high engine temperature digital input 2 low op input low oil pressure digit input 3 auxiliary warn auxiliary warn alarm digital input. 4 auxiliary shutdown when ...

  • Page 19: 8.  Setting Parameter

    Hgm6110/6120 auto start module hgm6110/6120 auto start module issue 2.0 2008-10-27 page 19 of 24 num item content remark 3 level sensor 0 not used 1 defined curve 2 sgh 3 sgd 4 reserve 5 reserve defined curve input resistance range is 0-999.9 ohm, default is not used 7.5 condition of crank succeed (...

  • Page 20: Note :sensor Config

    Hgm6110/6120 auto start module hgm6110/6120 auto start module issue 2.0 2008-10-27 page 20 of 24 event may occur. B. the over value point must be great than the under value. C. the configurable output 1 to 4 allow to set as same item. U information lcd will display the controller software version, i...

  • Page 21: 9.  Test Run

    Hgm6110/6120 auto start module hgm6110/6120 auto start module issue 2.0 2008-10-27 page 21 of 24 9. Test run before operation, inspections that are recommended as follows should be carried out: a. Check and assure that all connections are correct, and that diameter of wire is suitable; b. The dc pow...

  • Page 22

    Hgm6110/6120 auto start module hgm6110/6120 auto start module issue 2.0 2008-10-27 page 22 of 24 10. Typical wiring diagram hgm6110 typical wiring diagram hgm6120 typical wiring diagram.

  • Page 23: 11. Installation

    Hgm6110/6120 auto start module hgm6110/6120 auto start module issue 2.0 2008-10-27 page 23 of 24 single phase 2 wires (hgm6120) 2-phase 3 wires (hgm6120) 11. Installation the controller is designed to panel installation mode, and it is fixed by clamps when it is installed. The overall dimension and ...

  • Page 24: 12. Fault Finding

    Hgm6110/6120 auto start module hgm6110/6120 auto start module issue 2.0 2008-10-27 page 24 of 24 12. Fault finding symptom possible remedy unit is inoperative check the battery and wiring to the unit. Check the dc supply. Check the dc fuse. Unit shuts down check dc supply voltage is not above 35 vol...