SmartWitness SVC400L Installation Manual - page 13
13
SVC400L - Installation Instructions
9.5 Serial Port Setup
SETUP > PERIPHERAL > EXT.COM SETUP
There are two options to choose ; STANDARD and BUS MODE:
STANDARD mode you can select an external port for each COM
BUS mode COM1 and COM2 are for station announcement and the amplifier board respectively, and these two
are unchangeable; whereas COM3 and COM4 are changeable.
If COM1 is selected as the control panel, then you should connect the control panel to serial port 1 for it to run properly.
Please Note: COM1 means 232TXD1, COM2 means 485-2, COM3 means 485-3, and COM4 means 485-4. PTZ is
recommended to connect to either COM3 or COM4.
Take inertia sensor for example: if an inertia sensor is connected to SVA400L then you can find the values for the sensor in
GUI (SYSTEM > SENSOR > ACCELERATION and then press CHECK):
After installing the inertia sensor, make sure that the ENABLE switch is turned on. Then press CHECK to verify its current
values (all the values will be defaulted to 0).
If you move the
inertia sensor, then
the values for X/Y/Z
will change.