SMC Networks EX260-SDN1/3 Quick Start Manual - Specifications

Manual is about: Fieldbus System EX260 series Output Device for driving 5 port solenoid valves

Summary of EX260-SDN1/3

  • Page 1

    ® rohs ip67 ip67 ip67 ip40 top ported valve bottom ported valve side ported valve mixed valve sizes manifold 7 mm width valve applicable fieldbus protocols ex260 series fieldbus system (output device for driving 5 port solenoid valves) daisy-chain wiring communication space-saving installation space...

  • Page 2: 28.2

    Pwr bus in bus out e 3/5 1 p e 3/5 1 p b 4 a 2 b 4 a 2 b 4 a 2 b 4 a 2 b 4 a 2 pwr bus in bus out e 3/5 1 p e 3/5 1 p b 4 a 2 b 4 a 2 b 4 a 2 b 4 a 2 b 4 a 2 product specification variations m12 communication connector (profibus dp) d-sub communication connector (profibus dp) 28.2 mm 81 mm communic...

  • Page 3: Sy3000/5000/7000

    Sy3000 sy5000 sy7000 s0700 sv1000 sv2000 sv3000 vqc1000 vqc2000 vqc4000 vqc5000 0.19 0.17 0.20 0.39 0.35 0.18 0.21 0.30 0.30 0.38 0.31 1.6 3.6 5.9 0.37 1.1 2.4 4.3 1.0 3.2 7.3 17 series power consumption (w) enclosure standards flow rate characteristics (4/2 →5/3) c [dm 3 /(s·bar)] b maximum number ...

  • Page 4: Pr1

    M12 dn1 dn2 dn3 dn4 pr1 pr2 pr3 pr4 pr5 pr6 pr7 pr8 mj1 mj2 mj3 mj4 ec1 ec2 ec3 ec4 pn1 pn2 pn3 pn4 en1 en2 en3 en4 pl1 pl3 devicenet™ profibus dp ethercat profinet powerlink si unit output polarity 32 16 32 16 32 16 32 16 32 16 32 16 32 16 32 16 m12 m12 d-sub note) m12 m12 ethernet/ip™ m12 m12 sour...

  • Page 5: Ex260

    Si unit specifications model ex260-spr1/3 ex260-spr2/4 ex260-spr5/7 ex260-spr6/8 ex260-sdn1/3 ex260-sdn2/4 ex260-smj1/3 ex260-smj2/4 125 k/250 k/500 kbps 156 k/625 k/ 2.5 m/5 m/10 mbps m12 built-in — — 22.8 to 26.4 vdc 11 to 25 vdc 100 ma or less applicable system i/o occupation area (inputs/outputs...

  • Page 6: Ex260

    D-sub communication connector type m12 communication connector type 90.9 28.2 102.4 90.9 102.4 28.2 21 20.6 16.4 9 76.5 28.75 29.25 9 76.5 si unit dimensions part no. Communication protocol ex260-spr1/-spr2 -spr3/-spr4 profibus dp 5 pins, socket, b code 5 pins, plug, b code 5 pins, plug, a code note...

  • Page 7: 020

    White/orange orange white/green green accessories q communication cable with connector for si units compatible with profibus dp, devicenet™, cc-link for si units compatible with ethercat, profinet, ethernet/ip™, powerlink refer to page 907 for details. 020 ex9 ac en cable length (l) 1000 [mm] 2000 [...

  • Page 8: Ex500 Ap

    W power cable with connector (for si units) accessories ex500 ap 2 4 3 socket connector pin arrangement a code socket connector pin arrangement a code 1 1 2 3 4 5 terminal no. Core wire colors m12 connections (profibus dp/ethercat/profinet/powerlink) cable length (l) 1000 [mm] 5000 [mm] 010 050 conn...

  • Page 9: Ex9 Aw

    W power cable with connector (for si units) accessories e seal cap: for m12 connector socket ex9 aw use this on ports that are not being used for communication connector (m12 connector socket). Use of this seal cap maintains the integrity of the ip67 enclosure. Note) tighten the seal cap with the pr...

  • Page 10: Warning

    Design/selection 1. Use this product within the specification range. Using beyond the specified specifications range can cause fire, malfunction, or damage to the system. Check the specifications before operation. 2. When using for an interlock circuit: • provide a multiple interlock system which is...

  • Page 11: Caution

    Wiring operating environment 1. Do not use in an atmosphere containing an inflammable gas or explosive gas. Use in such an atmosphere is likely to cause a fire or explosion. This system is not explosion-proof. Operating environment 2. Provide adequate protection when operating in locations such as t...

  • Page 12: Warning

    Adjustment/operation warning 1. Do not perform operation or setting with wet hands. There is a risk of electrical shock. Maintenance 1. Do not disassemble, modify (including circuit board replacement) or repair this product. Such actions are likely to cause injuries or breakage. 2. When an inspectio...

  • Page 13: With The Same Cable.

    Send and receive on/off signals + unit information/status sending and receiving of unit information, error detection, or condition monitoring data manufacturer’s name, product number, version information output wiring disconnection, short circuit number of valve operations, operation threshold excee...

  • Page 14: Specifications

    Specifications wiring specifications item ex260-sil1-x207 ex260-sil1-x210 protocol io-link version 1.1 communication speed com2 (38.4 kbps)/com3 (230.4 kbps) (selected by dip switch) io-link port class (communication connector) class a (valve power supplied from the valve power supply connector) cla...

  • Page 15: How to Order

    Output connector (34 pins, receptacle) output common (0 v) solenoid output 0 solenoid output 2 solenoid output 4 solenoid output 6 solenoid output 8 solenoid output 10 solenoid output 12 solenoid output 14 solenoid output 16 solenoid output 18 solenoid output 20 solenoid output 22 solenoid output 24...