SMC Networks IDU11E-23-C,K,L,R,T,V Operation Manual - Warning
Air Dryer
2 Transportation / Installation
2 - 2
Installation
2 - 2 - 1 Location
The product should not be used or stored in the circumstances as follows.
Those circumstances will cause not only malfunction but also failures.
• Environment where the product is
exposed to rainwater, moisture vapor,
salty water, oil and so on.
•
Locations where dust or particles are.
•
Locations where inflammable or
explosive gas are.
•
Locations where corrosive gas, solvent,
combustible gas are.
•
Locations that receive direct sunlight or
where radiant heat is generated.
•
Locations where ambient temperature
is beyond following range:
On-stream: 2 ~ 40
o
C
Storage: 0 ~ 50
o
C (when there is no
drain water inside of the piping)
•
Locations where temperature changes
rapidly.
•
Locations where strong
•
electromagnetic noise is generated
(locations where electromagnetic field,
strong magnetic field, surge is
generated)
• Circumstances where static electricity
is produced or discharged through the
body of the product.
•
Locations where strong high frequency
wave is generated.
•
Locations where danger of thunder is
apparent.
•
Locations by loading on vehicles,
marine vessels, and so on.
•
Locations whose altitude is higher than
2,000 meters.
•
Circumstances where strong vibration
or impact are transmitted.
• Circumstances
where too much force
and weight are put on the body of the
product that causes it to deform.
• Circumstances where enough spaces
cannot be taken to do maintenance (in
the plant where the product is
operated).
Spaces needed for maintenance
Front :
600
mm
Rear :
600
mm
Top :
600
mm
Right :
600
mm
Left :
600
mm
• Locations the ventilation grille of the
product can be blocked.
• Place where rejection style air of air
compressor or other driers (hot wind) is
inhaled.
Warning
Do not use and store in environment having compressed air or ambinet atmosphere which
includes the following substances. It could result in failure of the product and damage of
components, which leads to injury.
- Corrosive gas, Organic solvent, Chemicals
2 - 2 - 2 Anchorage
•
The air dryer should be installed on a vibration-free, stable, horizontal flat surface.
•
Refer to “Chapter6 6-2 Dimensions” for the dimensions.
• Fix by bolts to prevent falling down. The bolts can be prepared separately as an accessory.
Model No.
Name
Quantity
Applicable Model
IDF-AB501
Anchor bolt set
1 (4 pcs
/1 set) IDU22E,IDU37E,IDU55E,IDU75E
2 - 2 - 3 Air
piping
•
Connection to the inlet and outlet of compressed air should be made removable by using union and so
on.
•
Pressing the hexagonal fitting with screw wrench and so on, connect the air piping fittings to the body.
•
When mounting any part such as an air filter on the fitting at the compressed air inlet or outlet port,
support the part to prevent excessive force from being applied to the product.
2 - 2