SMC Networks IZS30 SERIES Operation Manual

Manual is about: IZS30 SERIES Ionizer

Summary of IZS30 SERIES

  • Page 1

    Document no. : iz*-omj0003 operation manual product name: ionizer model: izs30 series ○read this operation manual carefully to understand before installation and operation. ○pay extra attention on the clause concerning the safety. ○keep this operation manual available whenever necessary..

  • Page 2: Contents

    Contents 1. Safety instructions.........................................................................................................2 2. How to order...................................................................................................................6 3. Specifications ...............

  • Page 3

    1. Safety instructions these safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard by labeling "caution", "warning", and "danger". To ensure safety, be sure to observe iso4414, jis b8370and other safety pre...

  • Page 4

    Warning 1. This product is made for general industry. Contact smc before use, if you are planning to use for other purposes. 2. Use under specified voltage and temperature. Voltage out of specification may cause malfunction, breakage, electric shock and fire. 3. Use clean compressed air for fluid. T...

  • Page 5

    Warning 1. Check that power supply capacity is enough and voltage is in specification before piping. 2. Apply type d earthing to prevent electrical shock in accordance with instructions on this operation manual. 3. Be sure to cut off power supply at wiring (inclu/ding connector plug-in/out) . 4. Use...

  • Page 6

    Product. K. The place where strong high frequency is generated. L. The place where lightning disaster is expected. M. The place where the product is directly exposed to the vibration and impact. N. The situation where the force and weight that causes deformation of the product is applied. 3. Do not ...

  • Page 7

    2. How to order i z s 3 0 – 7 8 0 s b i z s 3 0 - d 1 i z s 3 0 - c s i z s 3 0 - b e i z s 3 0 - n t bracket b mounted ∗ not mounted product name i z s 3 0 bar t ype ionizer bar length 300 300 mm 780 780 mm 1260 1260 mm 1500 1500 mm 1900 1900 mm bar length number of bracket for body middle part 300...

  • Page 8

    3. Specifications 3-1. Ionizer [note] *1: at distance 300mm between ionizer and charged object, with purge air. *2: the smallest flow rate for elimination at distance 200mm between ionizer and charged object. 3-2. Surface electric potential sensor ionizer model izs30 -300 izs30 -780 izs30 -1260 izs3...

  • Page 9

    4. Installation 4-1. Installation of ionizer body investigate the places where static problem occurs, or process and parts which generate esd (electro static discharge), and carefully consider the required conditions to ensure appropriate static charge elimination before installation. Operating dist...

  • Page 10

    4. Adjust angle of the ionizer body to ensure proper static charge elimination, and fix it with detent threads (m5) of brackets. Recommended tightening torque for detent thread: 1.5nm 4-2. Installation of surface electric potential sensor in case of using a surface electric potential sensor, install...

  • Page 11

    3. Peal off the seal attached on the detecting hole of the surface electric potential sensor. 4. Direct the surface electric potential sensor to the target’s static charge as adjusting the angle, and fix the detent thread (m5) of bracket. Recommended tightening torque for detent thread : 1.5 nm 4-3....

  • Page 12

    2. Arrange lead wires in accordance with the wiring table. The unused wires should be cut short or covered with vinyl tape without pealing the coat to prevent them from coming contact with other wires. See [4-4. Connection circuit ]. Wiring table for power supply cable izs30-cp note no. 6 and 8 only...

  • Page 13

    2. Arrange lead wires in accordance with the wiring table. The unused wires should be cut short or covered with vinyl tape without pealing the coat to prevent them from coming contact with other wires. See [4-4. Connection circuit ]. Wiring table for power supply cable izs30-cp note no. 6 and 8 only...

  • Page 14

    4. Insert the modular plug on the other side of sensor cable izs30-cs into the modular jack of the electric potential sensor. If the modular plug is properly inserted and locked, a lever clicks to notify it’s locked. Fix cables with a tie wrap or other measures in the vicinity of connection not to a...

  • Page 15

    4-4. Connection circuit ionizer power connector [note 1] indicates the coating color for lead wire of dedicated cable [note 2] connect [4. Stop signal of static charge elimination] to gnd when starting the ionizer operation. When the terminal is open, the operation will stop. [note 3] [6. Signal for...

  • Page 16

    5. Function description 5-1. Operation mode three operation modes are available in izs30. Use these modes depending on applications and operating conditions. Supplied voltage wave form image diagram op. Mode operation features precautions s en si ng d c m od e after surface electric potential sensor...

  • Page 17

    5-2. Output signal signal type function signal for static charge elimination completion (when surface electric potential sensor is used) output when static charge elimination is completed, or no target’s static charge exists. Abnormal high voltage output when any discharge probe gets shorted with ot...

  • Page 18

    6. Selection and setting of equipment 6-1. Sensing dc mode 1. Selection of bar length select the length applicable to work size base on [2. Static charge elimination area of 7-1. Static charge elimination characteristics (reference)] 2. Installation of ionizer body installation of ionizer body: inst...

  • Page 19

    7. Technical data 7-1. Static charge elimination characteristics (reference 1. Installation distance and static charge elimination time target’s static charge work charged plate dimensions:150×150mm capacity:20 @ f mean.Cond.:static el.Time for 3kv a 0.3kv installation distance and static charge eli...

  • Page 20

    2. Static charge elimination area ionizer depth direction ionizer width direction e f e g0ee g f e hee i h f e i hee i g f e i g0ee i f e e f e g0ee g f e hee h f e j0kmlon j0kmlon j0kmlon j0kmlon pqkmjon pqkmjon pqkmjon pqkmjon rskmjon rskmjon rskmjon rskmjon target’s work of static charge charged ...

  • Page 21

    Ionizer depth direction (with air purge) ionizer width direction ] with air purge ^ f e g0ee g f e hee f e e f e gsee gsee f e e f e w xsy w xsy w xsy w xsyz z z z [ x w [ x w [ x w [ x w z z z z \ x w \ x w \ x w \ x w z z z z f e g0ee g f e hee i hee i g f e i gsee i f e e f e gsee j0kmlon j0kmlon...

  • Page 22

    Charged amount and static charge elimination time operating frequency and static charge elimination time (w/o surface electric potential sensor) ` ` ` ` common conditions ` ` ` ` installed height:250mm air purge amount:20 l / min anr op.Freq.(in case of w/o sensor) : 33hz w/o sensor with sensor ch a...

  • Page 23

    7-2. Outline dimensions 1. Ionizer (izs30-**) n (number of cartriges) model n l (mm) izs30-300** 3 300 izs30-780** 9 780 izs30-1260** 15 1260 izs30-1500** 18 1500 izs30-1900** 23 1900 1hz op.Freq.33hz installation distance mm st at ic ch ar ge e lim in at io n tim e s ec ab c 2-pipefitting with chec...

  • Page 24

    End bracket (izs30-be) intermediate bracket } } } } izs30-bm ~ ~ ~ ~ )h dl g0i €dq j…„ a k thread for mounting m5 (should be prepared by user) angle ajustment available (±90°) a b j a b f e gmi €dq j…„ e b f e thread for mounting m5 (should be prepared by user) dqh‰o g)isu attached thread m4x10...

  • Page 25

    Surface electric potential sensor (izs30-d1) sensor bracket (izs30-bs) detecting hope e b m l)i ‹l 6p modular jack (for sensor plug for cable) 2x2-m5x0.8 dpt6 2-m5x0.8 dpt7 a b e b g0h a b e b b dq a b mounting hole 8 a e a attached thread m5x0.8 izs30-d1 shaft 8 for mounting (should be prepared b...

  • Page 26

    Power supply cable (izs30-cp) sensor cable (izs30-cs).