    Window / wall-type room air conditioner wa-6011s: 6000 btu wa-8011s: 8,000 btu wa-1011s: 10,000 btu wa-1211s: 12,000 btu thank you for your purchase. Before using your air conditioner, please read this manual carefully and keep it for future reference..

  • Page 2

    1 contents 1. Safety precautions ………………………………….2 2. Important safety instructions …………………3 3. Normal sounds ………………………………………...4 4. Air conditioner features …………………………4 5. Installation instructions …………………………9 6. Care and cleaning…………………………………...12 7. Troubleshooting tips………………………………13 8. Specificati...

  • Page 3: Safety Precautions

    2 to prevent injury or property damage, the following instructions must be followed. Failure to follow instructions and incorrect operation may cause harm or damage. Warning marks and classification: warning indicates possibility of death or serious injury. Caution indicates possibility of injury or...

  • Page 4

    3 note: for some models, the power supply cord with this air conditioner contains a current detection device designed to reduce the risk of fire. Please refer to the section “operation of current device” for details. In the event that the power supply cord is damaged, it cannot be repaired – it must...

  • Page 5

    4 note: all illustrations are for explanation purposes only. The actual appearance of the unit control may differ slightly, though functions and operations are the same high pitched chatter high efficiency compressors may have a high-pitched chatter during the cooling cycle. Gurgle / hiss “gurgling”...

  • Page 6

    5 air conditioner features (continued) note: the following instruction represent the unit controls, the same instructions can be used for the remote control. To turn unit on: do this: press the on/off button. Do this: press to increase press to lower to change temperature setting: to adjust fan spee...

  • Page 7

    6 do this: press the mode button. To select the operating mode: energy saver feature: do this: press the button. Note: press the mode button to select operating mode. With each press of the button, the mode will go through the following sequence: auto, cool, dry and fan. The indicator light next to ...

  • Page 8

    7 air conditioner features (continued) sleep feature: do this: press sleep button. Do this: press timer button. Do this: press check filter button. Display timer: auto start/stop feature: check filter feature: displays: sleep feature: when selected in conjunction with cool mode: unit will operate at...

  • Page 9

    8 additional things you should know now that you have mastered the operating procedures, here are some additional features: the cool circuit has an automatic 3-minute time delay when unit is turned off and on quickly. This protects the compressor from overheating and possible circuit breaker trippin...

  • Page 10

    9 your air conditioner is designed install in standard double hung windows with opening widths of 23 to 36 inches (584mm to 914mm) (see fig.1) lower sash must have sufficient vertical opening for installation (table 1). Side and rear of unit needs to be clear of obstacles to allow airflow through co...

  • Page 11

    10 installation note: top rail and side panels are offset to provide the proper pitch to the rear (5/16”). This is necessary for drainage of water condensation. If the side panels are not used, this pitch still needs to be maintained. 1. Place unit on floor or sturdy table. Install the side panels, ...

  • Page 12

    11 7. Install frame lock between the frame extension and the windowsill. Drive a ¾” (19mm) locking screw through the frame lock and into the sill (fig.7&8) note: to prevent the windowsill from splitting, first drill a 1/8” (3mm) pilot hole. 6. Insert and secure ½” (13mm) locking screws through frame...

  • Page 13

    12 air filter cleaning the air filter should be checked at least once a month to see if cleaning is necessary. Trapped particles in the filter can build up and cause an accumulation of frost on the cooling coils push the vent handle to the vent closed position (where applicable). Open the front pane...

  • Page 14

    13 before calling for service, review this list, it may save you time and expense. This list includes common occurrences that are not the result of defective workman-ship or materials in this appliance. Air conditioner does not start air from unit does not feel cold enough air conditioner cooling, b...

  • Page 15: Specifications

    14 model wa-6011s wa-8011s wa-1011s wa-1211s energy star cooling (btu) 6000 8000 10000 12000 dehumidify (pints/hr) 1.3 1.7 2.7 3.2 eer (btu/h.W.) 10.7 10.8 10.8 10.8 power input 115v~, 60hz 115v~, 60hz 115v~, 60hz 115v~, 60hz amps 5.4 7 8.8 10.2 watts 560 740 930 1110 power cord length 6 ft 6 ft 6 f...

  • Page 16

    15 location of the remote controller use the remote control within a distance of 5 meters (5.5 yards) from the appliance, pointing toward the receiver. Reception is confirmed by a beep. Cautions the air conditioner will not operate if curtains, doors or other materials block the signals from the rem...

  • Page 17

    16 operation starts when this button is pressed and stops when the button is pressed again. Push this button to increase the temperature setting in 1°c/1°f increments to 30°c/86°f. Auto operation ensure the unit is plugged in and power is available. 1. Press the on/off button to start the air condit...

  • Page 18

    17 cooling and fan operation ensure the unit is plugged in and power is available. 4. Press the on/off button to start the air conditioner. 5. Press the mode button to select cool or fan mode. 6. In cool mode, press the temp up/down button to set desired temperature. Temperature can be set within th...

  • Page 19

    18 timer operation press the timer button to initiate the auto-start or auto-off program. Timer can be set up to 24 hours. 1. Press the timer button to program timer-on or timer-off, the corresponding indicator will illuminate on unit’s control panel. 2. Press or hold the up/down button to program t...

  • Page 20

    19 your guarantee if this product is found to be faulty as a result of faulty materials or workmanship within one year from date of purchase, it will be repaired free of charge. This guarantee is subject to the following terms: • sunpentown must be notified of the fault. • proof of purchase must be ...