Sven SMART 1000 Operation Manual

Summary of SMART 1000

  • Page 1

    Www.Sven.Fi operation manual smart 1500 smart 1000 uninterruptible power supply.

  • Page 2: Eng

    Eng 1 operation manual 1 2 2 2 2 3 3 4 7 8 contents eng ................................................................................................ 1. Description ...................................................................................... 2. Safety precautions ..........................

  • Page 3: Eng

    Eng 2 caution! High voltage inside! To avoid the risk of electric shock do not open or touch elements inside. 1. Description smart 1000/1500 line-interactive ups is a perfect device for protection of computers and peripherals, such as monitors, modems, etc. In case of failure in the electric mains, ...

  • Page 4: Eng

    Eng 3 operation manual • usb and rj-11/rj-45 communication ports • cold start function in off-line mode • automatic electricity delivery at power supply renewal • short circuit and overload protection • modem/telephone circuit protection 5. Operation and storage conditions • do not operate the ups in...

  • Page 5: Eng

    Eng 4 7. Connection and operation connection of cables • place the ups into a suitable well-ventilated position (there should be at least 150 mm free space around the fan). • connect the power cable of the computer equipment to one of the ups output sockets h, and the monitor power cable – to the ot...

  • Page 6: Eng

    5 eng operation manual • when the power supply is renewed, the ups will automatically turn on and will charge its batteries. Ups switch-off • press the off button g on the front panel and hold it down for three seconds (daily switch-off), and the ups will enter bypass mode (if it’s plugged in), and b...

  • Page 7: Eng

    Eng 6 overloads and short circuit at the output • if the total input power of your equipment is more than the ups load capacity or there is short circuit, the fuse j on the rear panel can activate, and the ups will enter the off-line mode using battery power until the batteries are completely dischar...

  • Page 8: Eng

    7 eng operation manual 8. Troubleshooting problem the ups is plugged in, input voltage led c is off. The ups emits sound alarms and operates in off-line mode even in normal mains voltage conditions. The ups operates in on-line mode and doesn’t operate in off-line mode. The ups emits a sound alarm for 6...

  • Page 9: Eng

    Eng 8 9. Technical specifications 1000 24 2 × 7 145 × 245 × 355 12.0 24 2 × 9 145 × 245 × 355 13.9 1500 900 600 apparent power, va active power, w controlled variables protection input socket output sockets environment operating conditions input voltage, v input frequency, hz output voltage, v outpu...

  • Page 10: Smart 1500

    Smart 1500 smart 1000 Модели: smart 1000/1500 Импортер в России: ООО «СКАНДИТРЕЛ», 111024, РФ, г. Москва, ул. Авиамоторная, д. 65, стр. 1. Уполномоченная организация в России: ООО «РТ-Ф», 105082, г. Москва, ул. Фридриха Энгельса, д. 75, стр. 5. Условия гарантийного обслуживания смотрите в гарантийно...