SVT -4 Outdoor Station D User Manual

Summary of -4 Outdoor Station D

  • Page 1

    Svt-4 outdoor station d user manual please read this user manual prior to installing the system, and keep it well for future use..

  • Page 2

    Contents 1. Parts and functions.............................................................................................. 1 2. Terminal descriptions .......................................................................................... 2 3. Specifications........................................

  • Page 3

    -1- 1.Parts and functions 3 # description 1 built-in microphone 2 monitor button 3 intercom button 4 door unlock button 5 talk button 6 tft 7” color display 7 built-in speaker 8 talking/ring volume 9 brightness 10 contrast status light. Calling in: red light monitoring/talking: blue light # descript...

  • Page 4

    -2- 2.Terminal descriptions.

  • Page 5: 4.1.

    -3- 160-165 cm 1 2 4.Mounting hatch install into the wall screw hole screws (fix with button case) 3.Specifications outdoor station voltage: dc 14.5v no/nc: max. 14.5v, 120ma lock power supply: must be used according to lock. Unlocking time: 01 - 99 seconds communication duration: 120s. Communicatio...

  • Page 6: 4.2.

    -4- screw anchors screws screws (fix with rain cover) rain cover wall hole 4.2. Mounting with the rain guard 4.3. Mounting the indoor monitor.

  • Page 7: 5.1.

    -5- 5.1. Svt-4 system with one entrance system wiring and connections 5. Outdoor station 1 power supply for lock.

  • Page 8: 5.2.

    -6- 5.2. Svt-4 system with two entrances outdoor station 1 outdoor station 2 power supply for lock power supply for lock.

  • Page 9: 5.3.

    -7- 5.3. Svt-4 wiring connection 1. Red 2. Blue 3. Yellow 4. White 4-video 1-audio 2-gnd 3-v+ 5.3.1 indoor monitor 1. Red 2. Blue 3. Yellow 4. White 1. Red 2. Blue 3. Yellow 4. White note: do not remove any of the jumpers from the back of the indoor monitors. By removing a jumper or changing its pos...

  • Page 10

    -8- nc com no door lock to indoor monitor adjust talking volume exit button . Adjust camera position.

  • Page 11

    -9- 5.3.3 electric door lock connection 1. Use the port j3 of the lower module to connect a door lock. 2. The door lock is limited to 14.5v, 120ma. 3. Must use an additional power supply for the door lock. Ensure the power supply is compatible with the door lock specifications..

  • Page 12

    6.Cable requirements b a cable usage a b cat5 cable (must solder the wires together to ensure a good connection). Using different cables may affect the maximum distance the system can reach. 230 feet 70 meters 30 feet 10 meters note: 1. The system expands to a maximum of 2 outdoor stations and 4 ind...

  • Page 13: 7.1

    -11- press the call button at anytime, the indoor monitor will show the view from the front door camera automatically. Press talking button to have communication with the visitor by the front door. The visitor image shown on the monitor 7.1 visitor calls check after pressing the unlocked button, the...

  • Page 14: 7.2

    -12- all indoor monitors ring during the conversation between the outdoor station and the indoor monitor, press button on the main indoor monitor. The indoor monitor press button again to end the conversation. Call transferring from main indoor monitor to extension indoor monitor any indoor monitor ...

  • Page 15: 7.3

    -13- end the call all indoor monitors ring press the talkpress the talking button or hang-upbutton or hang- up the handsetthe handset talk begins any indoor monitor presses button or pick up the handset to talk. 7.3 intercom in the standby mode, press intercom button in any indoor monitor during the...

  • Page 16

    -14- 8.Settings - fingerprint manager modify administrator code enter the setting mode input the admin default code twice (1234+1234), the yellow led will be on. It is in the setting mode. The default code is: 1234 in the setting mode: press * 3 (yellow light blinks), and then enter a new administra...

  • Page 17

    -15- set the unlocking time in the setting mode: press * 1 (yellow light blinks), and then enter 2-digit number from 01 to 99 (bi- is heard, and yellow light stops blinking). This 2-digit number is the unlocking time. For example, enter 05 means the unlocking time is 5 seconds. Press # to exit the s...

  • Page 18

    Set security level in the setting mode: press * 5 (yellow light blinks), and then enter security level number twice(parameter range is 1, 2, 3, 4, 5. The higher number indicates the higher accuracy of fingerprint recognition). If bi- is heard, it indicates the setting is successful. If bi bi bi are ...

  • Page 20

    The design and specifications of this user manual can be changed without any notification to the user. All copyright and interpretation rights are reserved to svt innovations inc..