Tador Doorphone User Manual - page 2
Tador Technologies Doorphone User guide
2
Reassemble the panel over the base.
Attach the top cover to the base using the 4 screws.
Connect the power supply to the power inlet, Initiation tune will be sound.
Technician Programming:
Programming is possible via any extension only.
Entering to programming mode
:
o
Call the Doorphone's extension from any extension.
o
Type twice the number sign (##) wait for the confirmation beep.
The following values could be modified:
o
Speed dial when pressing the button
Implementation: type the cell number: 50
Type the telephone or extension number, up to 15 digits.
You can force breaks in the sequence of dialing by inserting
*
between digits.
Type # to confirm. A confirmation beep sound will be heard.
o
Delay time: delay time from the moment a press on the bypass pushbutton was detected,
till the moment the electric lock starts activating. (suitable for situations where there is a
distance between the Doorphone and the door)
Implementation: type the cell number: 01
Type the new delay value's 2 digits. (default 0 seconds)
Type # to confirm. A confirmation beep sound will be heard.
o
Opening time: the amount of time the lock stays unlatched.
Implementation: type the cell number: 02
Type the new opening time value's 2 digits. (default 3 seconds)
Type # to confirm. A confirmation beep sound will be heard.
o
Conversation time: the amount of time you can speak with the Doorphone till it hangs up.
If the value is smaller than 90 or equal, it represents seconds.
If the value is larger than 90, the second digit represents time in minutes.
The value is stored in cell #11, default value 60 seconds.
Implementation: type the cell number: 11 followed by the new value's 2 digits.
Type # to confirm. A confirmation beep sound will be heard.
o
Number of calling rings: the number of rings till the Doorphone answers when calling it.
Implementation: type the cell number: 12
Type the new calling rings value's 2 digits. (default 1 ring)
Type # to confirm. A confirmation beep sound will be heard.
o
opening keys from an extension: this is the key enables opening the door from remote.
Because the Doorphone can control 2 doors (the camera must be disabled by setting
"camera time" to 0) a different key must be set to each door. (incase a similar value is
set to the 2 doors, the opening key will open only the first door)
If only one lock is connected, the opening key should be typed twice.
The value is stored in cell #13, default value 7 to the first door and 5 to the second
(CAM terminals).
Implementation: type the cell number: 13
Type 2 digits the first stands for the first door and the second digit for the second door.
If only 1 door is used type the same digit twice.
Type # to confirm. A confirmation beep sound will be heard.
o
Camera time: the amount of time the camera stays on (the camera turns on
automatically after pressing the button or calling the Doorphone)
If instead of a camera a second lock is needed – this cell must be reset to 00, in this case
both locks will have the same opening time value.
The value is stored in cell #14, default value 30 seconds
Implementation: type the cell number: 14
Type the new Camera time value's 2 digits.
Type # to confirm. A confirmation beep sound will be heard.