Tahoe TI9000LXU Operation Instructions And Parts Manual - 3.

Manual is about: Gasoline

Summary of TI9000LXU

  • Page 1

    - 1 -.

  • Page 2: Contents

    - 2 - contents 1. Safety point for attention...................................................................................................................................................................................... 1 2. Parts & subassemblies .................................................

  • Page 3

    - 1 - 1. Safety point for attention 1) do not use it indoors 2) do not open it in wet 3) do not connect it to the line for house environment appliance 4) keep flammables 1m 5) do not overfill to cause over- min. Away from it flowing while fueling 6) do not smoke while fueling 7)stop the engine on fu...

  • Page 4: 2.

    - 2 - 2. . . . parts & subassemblies 1) fuel indicator 9)starting handle 2)fuel tank up 10)fuel filter cup 3)ac socket 11)fuel valve 4)ac breaker 12)air filter 5)voltmeter 13)choke handle 6)machine oil plug gap 14)exhaust silencer 7)engine switch 15) spark plug 8)discharging bolt 16)grounding termin...

  • Page 5: 3.

    - 3 - 3. . . . check-ups before operation · · · ·scope of temperature the genertor set is appli- cable for.-15 55 5℃ ℃ ℃ ℃ to 40 to 40 to 40 to 40℃ ℃ ℃ ℃. .. . · · · ·scope of humidity the generator is applicable for not over 95%. · · · ·the generator will output the rated power when running in area...

  • Page 6

    - 4 - 2 . . . .level of fuel a. Check the fuel level on the fuel indicator b. If the fuel level is too low,serew off the fuel tank cap fill it with fuel to the shoulder of the filter. Waring: do not overfill to avoid fuel overflowing. C. Remount the cap 3. Air filter a. Remove the filter cover. B. C...

  • Page 7

    - 5 - c. . . .it is dirty ,take out the element for cleaning · · · ·wash it in solvent · · · ·squeeze dry · · · ·drop some drips of machine oil into it. · · · ·squeeze it dry again. D. Remount the filter element and put it on filter cover. 4.Battery check to make sure that the electrolyte levelin ev...

  • Page 8: 4.

    - 6 - 4. . . .starting of generator starting with kick starter 1. Remove all loads from the ac output terminal. 2. Turn off the ac circuit breaker. 3. Open the fuel valve 4. Turn the choke handle to “close” positioon caution: do not close the choke when starting a hot engine. 5.Turn on the engine sw...

  • Page 9

    - 7 - 6. . . .gently hold the starting pull handle till some resistance is felt and then pull it abruptly. Waring: never let the starting pull handle retract suddenly but return it gently. 7. When the engine is warmed up,set the choke handle to “open” position electric start 1. Remove all loads from...

  • Page 10

    - 8 - 4. . . . set the choke handle to “close” position caution: do not close the choke when starting a hot engine 5: turn on the electronic start switch. 6. Release the electric start. 7: when the engine is warmed up,set the cloke handle to “open” position.

  • Page 11

    - 9 - 5. Usage of generator to keep the generator in optimal con- dition mechanically and electrically the following points shall be observed. Warning: the generator has to be ground for fear that any mistake would be made electrically. The total power of electric load shall not exceed the rated pow...

  • Page 12

    - 10 - · generator can’t work over load.It should be no more than 80% of rated power with load for long run. · for 3-phase model, each load should be equal, even the difference can not be over 30%,otherwise,the generator will be broken easily. · cable connected generator and load should conform to n...

  • Page 13

    - 11 - ok use of ac 1. Starting the engine. 2. Ensuring that the voltmete indictes voltage. 3. Connecting devices. 4: connecting the ac breaker note: over current will automatically turn off the ac breaker. When that is turned off,the generator shall be restarted with load reduced a few minutes ther...

  • Page 14: 6.

    - 12 - 6. . . .stopping of generator 1.Turn off the ac breaker. 2. Turn off the engine switch 3. Remove all loads. 4. Close the fuel valve. Note:when an emergent stop of the engine is needed,turn the generator switch to “off” position..

  • Page 15

    - 13 - 7. Mainte nance.

  • Page 16

    - 14 - 1. . . . replacing machine oil 1. Open the filling hole. 2. Remove the oil discharging bolt and drain off the used oil 3. Remount the oil discharging bolt tightly. 4. Fill the machine with fresh oil and check the oil level. Its machine oil capacity is 1.1l 5. Remount the oil plug gage. 2. Spa...

  • Page 17

    - 15 - 5. . . . remount the spark plug and its cap 3. Fuel filtering cup 1. Close the fuel valve 2. Remove the setting cup and straining screen. 3. Clean the cup and screen. 4. Remount the cup and screen.

  • Page 18: 8.

    - 16 - 8. . . . storage 1. Drain off fuel from the fuel tank. 2. Clean and then remount the straining screen and setting cup. 3. Drain of fuel from the carburetor. 4. Screw off the machine oil plug gage&discharging bolt and then drain off oil. 5. Remount the dis- charging bolt tightly,fill the machi...

  • Page 19: 9.

    - 17 - 9. . . . troubleshooting the engine can not start:.

  • Page 20

    - 18 - there is no voltage? Check the circuit protector. Check the spark plug.

  • Page 21

    - 19 - 10. Technical data item model ti9000lxu / ti9000lxt rated voltage (v) 120v / 240 rated output (kw) 6.5 max. Output (kw) 7.0 rated frequency (hz) 60 power factor 1.0 ro ta re n eg voltage regulate self-excited conxtant voltage engine model 190fd bore × stroke (mm) 90 × 66 compression ratio 8.0...

  • Page 22

    - 20 - 11. Battery unit ( electric ) 1. Mount the battery unit reliably in position with bolts, nuts and washers. 2. Get the electric start cable through under the tank and connect it to the solenoid. 3. Connect the grounding wire to the rear end of the generator. 4. Connect the electric start cable...

  • Page 23

    - 21 - instruction of using / maintaining generator maintainance – free battery respected customers: kindly read the instruction carefully before using the maintainance – free battery, which is composed of three parts. Part one: how to use the battery; part two: how to change the battery; part three...

  • Page 24

    - 22 - ★ ★ ★ ★ forbidden: not charge the battery in a long time. ★ ★ ★ ★ 4. Charge the battery within the restricted voltage (13.8v ~ ~ ~ ~ 14.4v), or there will be serious result. Part two: how to charge the battery 1. Start the generator by recoil starter when the electric charge in the battery is...

  • Page 25

    - 23 - 12. Wheel unit ( pick out and buy ) 1. Fix the four wheels to the axle by washers and pins. 2. Fix the wheel axle to the generator by bolts and nuts. 1) internal side 2) shorter side 3) longer side 4) wheel lock pin 5) lock dise 6) engine side 7) washer 8) pin 9) wheel 10) axle (on engine sid...

  • Page 26

    - 24 - loose parts list the following items are included with the generator: key no. Description ……………………… qty 1 wheel …………………………… 2 2 wheel axle ……………………… 2 3 large cotter pin ……………… 2 4 small cotter pin ……………… 4 5 clevis pin ……………………… 2 6 handle ………………………… 2 7 bolt …………………………… 6 8 frame support wi...

  • Page 27

    - 25 - unpacking this product requires assembly. ■ remove one end of the box and carefully slide out the generator and any accessories. Note: the generator is heavy. If you must lift the unit out of the box, get another person to help you and lift with your legs, not your back. ■ inspect the unit ca...

  • Page 28

    - 26 - ■ insert a large cotter pin through the hole in the axle. Bend the ends of the pin to secure. ■ repeat the process on the other side. Installing the frame supports see figure 2. Install the two frame supports provided on the bottom side of the generator frame opposite the wheels. ■ locate the...

  • Page 29

    - 27 - 13. Automatically gasoline generator manual Ⅰ Ⅰ Ⅰ Ⅰ. Introduction automatically gasoline generator is the intelligent generator without the operation by man. It will be automatically started and stooped when power cut and come. It could also automatically adjust the choke to fit the different...

  • Page 30

    - 28 - Ⅲ Ⅲ Ⅲ Ⅲ. The operating procedure of automatically control generator 1. Inspection and connection before use the generator a. Lock switch: place to “off” b. Control switch: place to “off” c. Connecting ac220v and install l, n and e respectively by qualified electrician. D. Connecting to 12v ba...

  • Page 31

    - 29 - 3. . . . maintenances notice a. Control switch must be put to “off” and disassemble the 220v power inlet before manual operating,manual/electrical starting or maintaining or changing the bettery. B. Longtime no use of generator: put lock switch and control switch “off” disassemble 12v battery...

  • Page 32

    - 30 -.

  • Page 33

    - 31 -.

  • Page 34

    - 32 -.