New generation digital infrared wireless conference system installation and operating manual v 2.8.
Remarks: all rights reserved for translation, reprint or reproduction contents may change without prior announcement all technical specifications are guideline data and not guaranteed features we are not responsible for any damage caused by improper use of this manual the equipment must be connected...
Important safety instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. The apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids, such as vases, shall be placed on the apparatus. 6. The main...
Important safety instructions attention: installation should be performed by qualified service personnel only in accordance with the national electrical or applicable local codes. Power disconnect: units with or without on – off switch have power supplied to the unit whenever the power cord is inser...
Lithium battery safety precautions to change battery please power off and take off the battery immediately. keep the battery away from heat sources to prevent fire or explosion. do not use a battery that is leaking, deformed, discolored or overheats. take extra precautions to keep a leaking ...
Contents installation & user guide ...........................................................................................................Ix chapter 1 system introduction ................................................................................................... 1 1.1 overview .............
2.5.16 video tracking setting ............................................................................................................................................ 28 2.5.17 si channel parameters setting ............................................................................................
4.3 infrared service area .................................................................................................................................................. 67 4.4 precautions in using ......................................................................................................
8.14 display language list .............................................................................................................................................. 103 appendix ........................................................................................................................
Installation & user guide about this manual this manual is a comprehensive guide to the installation and operation of taiden hcs-5300/80 new generation digital infrared wireless conference system. It includes the detailed description of the function and interface of the hcs-5300/80 system components...
Installation & user guide this manual is applicable to: digital ir wireless conference system main unit hcs-5300ma/80 digital ir wireless conference system main unit (discussion, voting, 1+7 chs, with interface for hcs-4100/50 series wired congress unit and interpreter unit, dante interface) hcs-5...
Installation & user guide dedicated cable cbl5300-05 5 m dedicated transceiver cable cbl5300-10 10 m dedicated transceiver cable cbl5300-20 20 m dedicated transceiver cable cbl5300-30 30 m dedicated transceiver cable cbl5300-40 40 m dedicated transceiver cable cbl5300-50 50 m dedicated transceiver c...
Chapter 1 system introduction 1.1 overview taiden hcs-5300/80 series product is a digital infrared wireless conference system convenient for mobile use as well as for permanent installations. The flexibility of the wireless chairman and delegate units allows easy arrangements of various conferences....
The system is composed of one or more of the following: digital ir wireless conference system main unit hcs-5300ma/80 digital ir wireless conference system main unit (discussion, voting, 1+7 chs, with interface for hcs-4100/50 series wired congress unit and interpreter unit, dante interface) hcs-5...
Cbl5300-05cmp 5 m dedicated transceiver cable (cmp) cbl5300-10cmp 10 m dedicated transceiver cable (cmp) cbl5300-20cmp 20 m dedicated transceiver cable (cmp) cbl5300-30cmp 30 m dedicated transceiver cable (cmp) cbl5300-40cmp 40 m dedicated transceiver cable (cmp) cbl5300-50cmp 50 m dedicated transce...
1.2 functions and features 1. Digital infrared wireless conference system operating taiden diratc technology - digital infrared audio transmission and control technology 2. Wireless conference system quick set up and removal, free from troubles resulting from cable breaks and cable deteriorations ...
1.3 system technology 1.3.1 basic system concept the system composition of hcs-5300/80 new generation digital infrared wireless conference system is shown in figure 1.2. It is composed of: new generation digital infrared wireless conference units for participators new generation digital infrared...
1.4 aspects of infrared signal transmission to benefit from the advantages of a digital infrared wireless conference system the signals should be transmitted undisturbed. This is achieved by using digital infrared transceivers well positioned and sufficient in quantity to ensure uniform and adequate...
1.4.3 infrared service area of digital infrared wireless conference unit infrared light is directional invisible light. Infrared wireless conference unit gets best sensitivity when it directly faces a transceiver. Every hcs-5300/80 series new generation digital infrared wireless conference unit is e...
1.4.4 infrared service area of digital infrared transceiver the type of the digital infrared transceiver determines the covering area. More transceivers can enlarge the covered area. The coverage area is determined by the intersection of the infrared working area of the digital infrared transceivers...
1.4.5 overlap and multipath effects if footprints of two transceivers overlap, its total coverage area may be larger than the sum of the two separate footprints. In an area with overlap effect, the individual radiation signals of two transceivers are added, resulting in an increase of the radiation ...
Chapter 2 digital ir wireless conference system main unit 2.1 overview hcs-5300m/80 digital infrared wireless conference system main unit is the heart of the hcs-5300/80 wireless conference system. The main unit can be connected to digital infrared transceivers and recording devices and: display s...
2.2 functions and indications front panel of hcs-5300m/80 main unit rear panel of hcs-5300ma/80 main unit rear panel of hcs-5300mb/80 main unit rear panel of hcs-5300mc/80 main unit figure 2.1 new generation digital infrared wireless conference system main unit 11.
Front panel: 1. “standby” button 2. “menu” button the lcd displays the initial user interface: press this button to enter the lcd set-up menu; the lcd displays the set-up user interface: press this button to select the highlighted item or enter the submenu; the lcd displays the network configu...
2.3 installation hcs-5300m/80 series new generation digital infrared wireless conference system main unit can be fixed in a standard 19-inch cabinet. The main unit is equipped with a pair of fixing brackets ①. First unscrew the lateral screws ② from the housing. Then fasten the brackets with these s...
2.4 connection several typical system connections of hcs-5300m/80 series main unit will be introduced in this section, including connection: to interpretation devices to other auxiliary devices to hcs-8300mi series system connection[wired/wireless discussion + digital simultaneous interpreta...
2.4.2.3 to pa hcs-5300m/80 series new generation digital infrared wireless conference system main unit has audio output interfaces which can be connected to a pa system. Use an audio cable to connect “line out 1” or “line out 2” of hcs-5300m/80 to the input interface of pa. Figure 2.7 digital infrar...
2.4.4 system connection 1 [wired/wireless discussion + digital simultaneous interpretation + voting + video tracking] hcs-5300ma/80 has the functions for discussion, vote and digital simultaneous interpretation. The system can be connected to an automatic video tracking system. For video tracking pu...
2.4.5 system connection 2 [wired/wireless discussion + digital simultaneous interpretation + video tracking + central control] hcs-5300mb/80 has the functions for discussion and digital simultaneous interpretation. The system can be connected to an automatic video tracking system. For video tracking...
Figure 2.10 system connection [wired/wireless discussion + digital simultaneous interpretation + video tracking + central control] 18.
2.4.6 system connection 3 [wireless discussion + video tracking + central control] hcs-5300mc/80 has the functions for discussion. The system can be connected to an automatic video tracking system. For video tracking purposes, the application software is used to make camera presets for every confere...
Figure 2.11 system connection [wireless discussion + video tracking + central control] 20
2.4.7 load capacity hcs-5300ma/mb/80 main unit can connect to and power for digital infrared wireless transceiver, wired congress unit and interpretation unit. So, devices type and quantity must be considered synthetically when designing a system. The hcs-5300m/80 main unit can connect to 10 transce...
2.5 configuration and operation digital infrared wireless conference system main unit can be configured and set up through menu operation with four buttons. All menu items operation will be introduced one by one in this section. A) starting initialization switch on and press the "standby" button, th...
“dante audio mode” “set rs-232 baudrate” “noise elimination” “line out1 noise gate setting” “about” “about dante” press the “menu” button to go to the corresponding submenus; to switch from term to term use the “/” button; to exit the current menu and to return to the upper level menu use th...
if “0” is selected, it stands for no si function, use the “menu” button to save and return to the main menu; if other values are selected, it stands for the number of interpretation channels, use the “menu” button to go to step b). B) select language of channel 1). Set up channel 1 first, use th...
2). Press the “ /” button to select auto-relay booth quantity and press the “menu” button to go to the next step; 3). Press the “ /” button to select auto-relay booth and press the “menu” button to confirm, then the corresponding booth number will be highlighted and set as auto-relay booth. Pres...
2.5.5 downlink audio treble setting adjust downlink treble of the floor, range: -15db - +15 db. A). Press the “ /” button to adjust; b). Press the “menu” button to save and return to the upper level menu. 2.5.6 monitor setting the audio input and output can be monitored with a headphone at the mon...
2.5.10 microphone parameters setting 1. “microphone gain setting” a). Press the “ /” button to select “set all mics” or “set active mic(s)”; b). Press the “menu” button to go to the next step. C). Press the “ /” button to select “specified value” or “step adjustment”; “specified value a). Pres...
B). Press the “menu” button to save and return to the next carrier setting interface; c). After all carriers are set, press the “menu” button to save and return to the upper level menu. 2.5.13 language a). Use the “ /” button to switch language from “中_ 简”, “中_繁”, “english”; b). Use the “menu” but...
2.5.17 si channel parameters setting set the parameters of the si channel. A). Press the “menu” button to view the channel state. If a channel hasn't been fed with language output temporarily, the led displays “not engaged”, and if the microphone of the interpreter unit in the booth is active, the a...
B). Press the “menu” button to save and return to the upper level menu. “auto turn off time” a). Press the “ /” button to select “auto turn off time” and press the “menu” button to enter the setup interface, press the “ /” button to select for “3s”, “5s” or “10s”, shown in the following figure...
2.5.25 mic. Led setting set up the color of indicator lamp rings when turn on the microphone and the “on/off” button. A) press the “ /” button to select “green for mic. On” or “red for mic. On”; option state mic. Button green for mic. On speaking green green apply red red voice (no speaking) red o...
Figure 2.13 audio mode setting – normal mode figure 2.14 audio mode setting – remote conferencing mode1 32.
Figure 2.15 audio mode setting – remote conferencing mode2 figure 2.16 audio mode setting – external process mode1 33.
Figure 2.17 audio mode setting – external process mode2 34.
2.5.27 usb audio setting enable/disable usb audio function. The usb audio will engage one si channel. A) press the “ /” button to select “yes” or “no”; b) press the “menu” button to save and return to the upper level menu. 2.5.28 license install the web server process and see the licenses list of ...
2.5.34 about dante dante information includes: dante version, device version and device name, as shown in the following figure - press any button to return to the upper level menu. 2.5.35 volume control the volume can be adjusted by the volume knob on the cmu front panel - line in 1 vol. Adjust knob...
2.6 usb audio hcs-5300m has a built-in usb audio (1 channel, 16bit, 32khz) which can be connected to the computer through usb cable (software requirement: windowsxp or higher) for digital audio input/output. We take win7 system as an example to introduce the function and operation of the usb audio. ...
2.6.2 digital audio input when the hcs-5300m main unit is connected to the computer, the conference units connected in the system are the microphone for digital audio input. Using the recording software or the third party communication software, such as recorder, skype or qq and so on, functions lik...
2.6.3 digital audio output the hcs-5300m main unit can be connected to the computer for digital audio output. Please adjust and test the hcs-5300m ubs audio to a suitable volume when first using. Adjust method: open the control panel-sound (or right click the volume icon on the taskbar and select so...
Chapter 3 digital infrared transceiver 3.1 overview the digital infrared transceiver manages the communication between the main unit and the conference units. It can be mounted onto the ceiling or the wall for optional coverage or fixed onto a tripod at any appropriate spot. Types: hcs-5300td/80 dig...
3.2 functions and indications 3.2.1 digital infrared transceiver hcs-5300td digital infrared transceiver hcs-5300tds digital infrared transceiver hcs-5300th/80 digital infrared transceiver hcs-5300tw/80 digital infrared transceiver figure 3.1 hcs-5300t digital infrared transceiver figure 3.1: 1. 2-m...
3.2.2 digital infrared cable splitter hcs-5352 digital infrared cable splitter with one input and four outputs that can be used to connect four transceivers/ receivers at most. Figure 3.2 hcs-5352 cable splitter figure 3.2: 1. To the transceiver interface of the main unit 2. Four transceiver/ receiv...
3.3 infrared service area a.Hcs-5300td(s)/80 b.Hcs-5300th/80 c.Hcs-5300tw/80 * the table above is the coverage area of a single transceiver; but the actual coverage area will be affected by the number of the transceivers and the length of the cable connected in the system. Figure 3.3 service area of...
3.4 position planning 3.4.1 precautions in planning the digital infrared transceiver/receiver due to strict demands on intensity and stability of infrared signals in an infrared wireless conference system, please read section 1.4 carefully and take all aspects of infrared signal transmission into co...
3.4.1.4 make each conference unit communicating with more than one transceiver as shown in the following figure: when the speaker in the front row speaks in an upright position, the infrared signal will be blocked. In conference rooms with conference units in rows, each conference unit should commun...
3.4.2 planning digital infrared transceiver the coverage area of the digital infrared transceiver is defined by the distance between the transceiver and the conference unit. Select suitable transceiver type according to the height of the conference room, locate them at reasonable positions and place...
3.4.2.2 example for planning the transceiver 【square table arrangement】 if the transceivers are arranged as shown in the following figure, the coverage area of infrared signals will cover the entire meeting room. Figure 3.12 planning the transceiver (square conference room) 【round table arrangement】...
A) conference style seating (circulatory seating) within the circulatory seating operating area of the conference units, the transceivers must be placed evenly. Make sure that all conference units communicate with at least two transceivers. Figure 3.14 arrangement according to the seating style (con...
【chairman platform】 to get awider and farther coverage area within 5 meters height, hcs-5300tw/80 digital infrared transceiver is strongly recommended for the meeting place where the height is lower than 5 meters, such as chairman platform. Figure 3.18 planning the transceiver (chairman platform) 【b...
3.4.3.2 using distributor if using distributors, do not use more than one distributor in one branch, or it will increase high frequency signal loss and may cause system fault. Connections to transceivers with and without distributors in the branch, cannot work together in one system. When installed ...
3.5 installation 3.5.1 installation of hcs-5300td/80 3.5.1.1 ceiling mounted 1 ① hcs-5300td/80 digital infrared transceiver ② hcs-5300td/80 digital infrared transceiver ceiling-mounting kit ③ mounting hole (drilled on the ceiling) ④ ceiling figure 3.22 hcs-5300td/80 digital infrared transceiver ceil...
3.5.1.2 ceiling mounted 2 ① m3 screw ② hard ceiling mounting bracket ③ rubber plug ④ hard ceiling (such as concrete ceiling) ⑤ hcs-5300td/80 digital infrared transceiver figure 3.23 hcs-5300td/80 digital infrared transceiver ceiling mounted mounting steps: step 1: position the mounting bracket on th...
3.5.1.3 tripod mounted (adjustable angle) ① hcs-5300td/80 digital infrared transceiver ② m3 screw ③ wall-mounted bracket (with flexible tube) ④ tripod-mounted stator ⑤ hcs-5300tzj2 (should be ordered separately) figure 3.24 hcs-5300td/80 digital infrared transceiver tripod mounted mounting steps: st...
3.5.1.4 tripod mounted ① hard ceiling mounting bracket ② hcs-5300td/80 digital infrared transceiver ③ hcs-5300tzj2 (should be ordered separately) figure 3.25 hcs-5300td/80 digital infrared transceiver tripod mounted mounting steps: step 1: put the bracket on the bottom of the transceiver and fix it ...
3.5.1.5 wall mounted (adjustable angle) ① hcs-5300td/80 digital infrared transceiver ② m3 screw ③ wall-mounted bracket (with flexible tube) ④ wall figure 3.26 hcs-5300td/80 digital infrared transceiver wall mounted mounting steps: step 1: fix the hcs-5300td/80 digital infrared transceiver onto the w...
3.5.2 installation of hcs-5300tds/80 ① m6×60 hook up riveting bolt ② m4 screw(m4×40)and nut ③ user customized suspension (see figure 3.30 for requirements) or hcs-5300tdp suspension (optional length) ④ m3×12 screw ⑤ hard ceiling (such as concrete ceiling) figure 3.27 hcs-5300tds/80 digital infrared ...
Figure 3.28 requirements of user customized suspension 57.
3.5.3 installation of hcs-5300th/80 3.5.3.1 ceiling mounted ① hcs-5300th/80 digital infrared transceiver ② hcs-5300th/80 digital infrared transceiver ceiling-mounting kit ③ mounting hole (drilled on the ceiling) ④ ceiling figure 3.29 hcs-5300th/80 digital infrared transceiver ceiling mounted mountin...
3.5.3.2 tripod mounted (adjustable angle) ① hcs-5300th/80 digital infrared transceiver ② m3 screw ③ wall-mounted bracket (with flexible tube) ④ tripod-mounted stator ⑤ hcs-5300tzj2 (should be ordered separately) figure 3.30 hcs-5300th/80 digital infrared transceiver tripod mounted mounting steps: st...
Wall mounted (adjustable angle) ① hcs-5300th/80 digital infrared transceiver ② m3 screw ③ wall-mounted bracket (with flexible tube) ④ wall figure 3.31 hcs-5300th/80 digital infrared transceiver wall mounted mounting steps: step 1: fix the hcs-5300th/80 digital infrared transceiver onto the wall-moun...
3.5.4 installation of hcs-5300tw/80 ① m3 screw ② rubber plug ③ wall ④ hcs-5300tw/80 digital infrared transceiver figure 3.32 hcs-5300tw/80 digital infrared transceiver wall mounted mounting steps: step 1: drill two holes (5 mm diameter, 30 mm depth and 100.6 mm interval) into the wall; step 2: put t...
3.6 connecting to main unit connect the transceiver to the main unit with designated 6-pin 100 mbps high speed cable (see figure 3.33). Figure 3.33 digital infrared transceiver connecting to digital infrared wireless conference main unit note: the correctness of the cable connection can be ascerta...
Chapter 4 digital infrared wireless conference unit 4.1 overview hcs-5300/80 series digital infrared wireless conference units are the basic devices for the participators, divided into delegate unit and chairman unit with priority features. Different functions are available, depending on the confere...
4.2 functions and indicating hcs-5300ce/80 hcs-5300de/80 hcs-5302d/80 hcs-5302c/80 hcs-5301d/80 bottom side left side ( functions for 5301d/80 only ) right side figure 4.1 hcs-5300/80 series new generation digital infrared wireless conference unit 64.
Figure 4.1: 1. Infrared transmitting/receiving glass – at the frontage of the conference unit for transmitting/ receiving infrared signals. 2 .Charging indicator 3. Fully charged indicator 4. Lcd – display for channel number, language name, signal icon, battery capacityand emission angle. 5. Channel...
start/stop/candidate5/response++ (“start/stop/5/++”): a. In questionnaire/opinion poll state of voting mode, voting indicating light will blink, press this button to vote for candidate 5; b. In audience response/rating state of voting mode, voting indicating light will blink, press this button to ...
4.3 infrared service area infrared light is directional invisible light. Infrared wireless conference unit gets best sensitivity when it directly faces a transceiver. Every hcs-5300/80 series new generation digital infrared wireless conference unit is equipped with infrared glass at its frontage to ...
4.4 precautions in using avoid direct sunshine when using, otherwise it may cause signal blocking. Figure 4.3 close curtain to avoid direct sunshine the distance between adjacent conference units must be at least 0.5 meter; the distance between opposite conference units must be at least 0.8 mete...
4.5 operation the operation of the chairman unit and the delegate unit will be introduced in detail in this section. 4.5.1 the operation of delegate unit hcs-5300d/80 is taken as reference to introduce the operation of the digital infrared wireless delegate unit. Hcs-5300d/80 delegate unit combines ...
for “last key-press valid” voting, the delegate can change his/her vote. When the delegate voted, the indicating light of his voted key will be activated and all other indicating lights will be deactivated. About 1 second later, all indicating lights will blink again, and the delegate may change h...
4.5.2 the operation of chairman unit the chairman unit features the functions of a delegate unit and in addition priority function: if the priority mode is set as “all mute” in the main unit configuration, all active conference units will be muted when the priority button on the chairman unit is p...
Chapter 5 web control software apply model: hcs-5300ma/80、hcs-5300mb/80、hcs-5300mc/80; running environment: browser for firefox29.0, google25.0, ie10 or higher. 5.1 login and exit the user inputs the ip address of the cmu into the web browser to login. The default username is “admin” and the default...
Input the username and password, then click the “login” button and it will enter the conference management system interface automatically. Figure 5.2 conference management system there are two buttons in the right top of the interface: password change: click this button and the below dialog box is s...
5.2 conference management 5.2.1 assign unit id to delegate it will list all id of connective units in the system. User can assign them to delegates, open microphones, set up the camera predefine position, etc.. The interface is shown in the following figure: figure 5.3 assign unit id to delegate id:...
5.2.2 speaking and request list speaking and request list displays the information of the active and requested microphones, includes mic. Id, delegate name, camera control and unit type. Figure 5.4 speaking and request list turn off all mic.: turn off all the microphones on the speaking list; turn o...
5.2.3 cmu setting cmu setting includes operation mode, active microphones and loudspeaker volume. The cmu setting interface as shown in the following figure: figure 5.5 cmu setting operation mode: set up the speaking mode, include open/ override/ voice/ apply; ♦ “open”: if the number of active micro...
5.2.4 video matrix it includes video matrix and video switch. The matrix, tmx-0804, is a high definition video matrix which includes one 8x4 video matrix. 5.2.4.1 video matrix the setup of the video matrix interface is shown in the following figure: figure 5.6 video matrix select model: system will ...
5.2.4.2 video switch the interface of the video switch is shown in the following figure: figure 5.7 video switch matrix switch: 1. According to the setup of the video matrix, the video input type will be displayed automatically; 2. Assign corresponding output channel by clicking on the cross point o...
5.2.5 predefined position if the conference system is equipped with cameras, the system can carry out automatic video tracking, i.E. Display the image of the speaking participator to the display devices (large screen, tv, and so on). Predefine position is to set the predefined position of each micro...
5.2.6 s.I. Setup it includes channels, booths and language setting. The interface of s.I. Setup is shown in the following figure: figure 5.9 s.I. Setup channels: supports 7 s.I. Channels at most. If there are wired conference units connected, the maximal number of channels is 3; the system support...
Note: the user-defined language only supports a sequence of numbers or letters (case sensitive) with a maximum of 8 characters, the abbreviation supports a maximum of 3 characters. 81.
Chapter 6 accessories 6.1 digital ir conference room switcher 6.1.1 functions and indications front panel of hcs-5300mx rear panel of hcs-5300mx figure 6.1 hcs-5300mx digital ir conference room switcher 1. Mains switch 2. 16×2 segment lcd 3. “menu” button the lcd displays firmware version. 4. “exi...
6.1.2 connection 6.1.2.1 splitting/combining several meeting rooms 1 several meeting rooms can be split/ combined at leisure through the hcs-5300mx digital ir conference room switcher with cbl5300 cable. One hcs-5300mx can combine up to four meeting rooms. Figure 6.2 splitting/combining several meet...
6.1.2.2 splitting/combining several meeting rooms 2 several meeting rooms can be split/combined at leisure through the hcs-5300mx with cbl5300 cable to connect the transceivers and the hcs-8300mx with 6pin to rj45 cable to connect the interpreter units. Four meeting rooms can be combined up at most ...
6.1.3 configuration and operation switch on hcs-5300mx digital ir conference room switcher, it will start initialization: when the initialization is finished, the corresponding state of input channels and output groups will be displayed on the lcd: press the button at the front panel and go to the n...
6.2 accessories hcs-5300 can be power supplied by specific lithium battery or power adapter. Figure 6.4 hcs-5300bat lithium battery assemble procedure: 1. Assemble the battery into the slot on the bottom of the conference unit with the buckles on the right and left side of the battery aiming to th...
6.3 charging device the charging unit can recharge up to 8 hcs-5300bat batteries at one time by using universal power supply with automatic voltage matching. A charging indicator and a fully charged indicator on the charging unit are displaying the battery status. The charging circuit will check if ...
6.5 dedicated extension cable for digital infrared transceiver cbl5300 dedicated cable is used to connect the digital infrared transceiver and the digital infrared wireless conference main unit. It features one male 6p-din connector at one end and one female 6p-din connector at the opposite end. Ava...
6.7 earphones the earphones are connected to the conference units via an Ø 3.5 mm stereo jack. Suitable earphone types include: ep-820as single earphone ep-829 single earphone ep-829sw single earphone hcs-5100pa headphone ep-960bh headphone any other compatible type (see chapter 8, techn...
Chapter 7 fault diagnosis some simple trouble-shooting instructions are provided in this chapter. If more serious faults arise, please contact a qualified technician. 7.1 digital infrared wireless conference unit fault analysis solution cannot startup. The battery is not charged (when using the lith...
7.2 digital infrared wireless main unit fault analysis solution cannot startup. No power supply or no power cord connected to main unit. Connect the power supply with the power cord. 7.3 charging unit fault analysis solution the power indicating light is not on when the unit is powered on. The power...
Chapter 8 technical data 8.1 system specification system performance conforms to iec 60914, the international standard for conference systems the carrier frequency (0~3) transmitted by the main unit conforms to iec 61603-7, the international standard for digital infra-red transmission of audio signa...
8.2 new generation digital infrared wireless main unit type hcs-5300ma/80 hcs-5300mb/80 hcs-5300mc/80 discussion √ √ √ simultaneous interpretation max. (1+7) channels max. (1+7) channels - vote √ - - dante √ - - mains voltage ac 100 v-120 v 60 hz or ac 220 v-240 v 50 hz power consumption max. 160 w ...
8.3 digital infrared transceiver type hcs-5300td/80 hcs-5300tds/80 voltage 33 v dc (supplied from hcs-5300) current consumption max. 550 ma mounting tripod, wall or ceiling mounted suspension inf rar ed e m it ter /d et ec tor wavelength 870 nm modulation method dqpsk carrier frequency 1 ~ 8 mhz com...
Type hcs-5300th/80 hcs-5300tw/80 voltage 33 v dc(supplied from hcs-5300m) 24 v dc(supplied from hcs-adp24v) current consumption max. 550 ma mounting tripod, wall or ceiling mounted wall mounted inf rar ed e m it ter /d et ec tor wavelength 870 nm modulation method dqpsk carrier frequency 1 ~ 8 mhz c...
8.4 new generation digital infrared wireless conference unit type hcs-5300ce/80 hcs-5300de/80 hcs-5301d/80 hcs-5302d/80 hcs-5302c/80 discussion √ √ √ √ √ voting 5 keys - - - simultaneous interpretation 1+7 channels 1+7channels 2×(1+7) channels - - priority key √ - - - √ voltage 11.1 v dc (hcs-5300ba...
Type hcs-5300ce/80 hcs-5300de/80 hcs-5301d/80 hcs-5302d/80 hcs-5302c/80 weight (excl. Battery) 0.5 kg weight (incl. Battery) 0.8 kg color silver/ charcoal gray m ic rophone type uni-directional electret condenser microphone sensitivity -46 dbv/pa frequency response 30-20000 hz directivity 0°/180° >2...
8.5 digital ir conference room switcher type hcs-5300mx mains voltage ac 100 v - 120 v 60 hz or ac 220 v - 240 v 50 hz power consumption 15 w input interfaces 4 6p-din sockets output interfaces 20 6p-din sockets in 4 groups, 5 sockets per group dimensions weight 10.6 kg color white 8.6 lithium batte...
8.7 charging device type hcs-5300chg/08 mains voltage ac 100 v - 240 v 50/60 hz power consumption max. 380 w charging time approx. 6 hours charging capacity 8 hcs-5300bat batteries led indicator power indicator charging status (green: full charge or battery not inserted, red: on charge) dimensions w...
8.9 distributor type hcs-5352 voltage 33 v dc (supplied from hcs-5300m) number of i/o terminals 1 in / 4 out connector 4 x 6p-din socket + 2.1 m cable with 6p-din plug dimensions 149 (w) x 35 (h) x 90 (d) mm weight 0.3 kg color charcoal gray 8.10 cbl-5300 dedicated extension cable hcs-5300td/tds/8...
8.12 earphones ep-820as single earphone used with the receiver/conference unit hi-fi sound quality Ø 3.5 mm stereo plug 32 Ω (tip and sleeve, ring: nc) frequency response: 50 hz to 20 khz sensitivity: ≥102 dba/1 mw weight: 20 g ep-829 single earphone used with the receiver/conference...
8.13 connection details mains cables blue neutral brown live green/yellow earth/ground audio cables chinch connector (male) pin① signal + pin② gnd earphones 3.5 mm jack plug tip① signal left ring② signal right sleeve③ electrical earth/screen emergency switch terminal block connect the emerge...
8.14 display language list № chinese english abbr. № chinese english abbr. № chinese english abbr. 0 原声 floor flo 33 巴厘语 balinese ban 66 加利西亚语 galician glg 1 阿尔巴尼亚 albanian alb 34 孟加拉国语 bengali ben 67 古吉特语 gujarati guj 2 阿拉伯语 arabic ara 35 缅甸语 myanmar mya 68 夏威夷语 hawaiian haw 3 保加利亚语 bulgarian bul 3...
Appendix dedicated 6 pin extension cable 104.
Copyright by taiden last revision: 03/2018 taiden industrial co., ltd. 6/f, block b, future plaza, 6060 qiaoxiang rd, nanshan district, shenzhen,china p.C.: 518053 website: http://www.Taiden.Com.