Ag-1000 user’s manual sms alert gateway all contents are subjected to change without prior notice rev 7.3 copyright © 2005 taiko network communications pte ltd um-ag1000_r7.2 ag1000-01 revision: 8 sms alert gateway (8 di 4do).
Page 2
Ag-1000 user’s manual sms alert gateway all contents are subjected to change without prior notice rev 7.3 copyright © 2005 taiko network communications pte ltd um-ag1000_r7.2 contents guidance for the manual ...............................................................................................
Page 3
Ag-1000 user’s manual sms alert gateway all contents are subjected to change without prior notice rev 7.3 page 1 of 27 copyright © 2005 taiko network communications pte ltd guidance for the manual section 1 - introduce the basic features of sms alert gateway; section 2 - cover the hardware descripti...
Page 4
Ag-1000 user’s manual sms alert gateway all contents are subjected to change without prior notice rev 7.3 page 2 of 27 copyright © 2005 taiko network communications pte ltd section 1 introduction 1.1 product overview sms alert gateway is designed as a cost effective remote system alert device which ...
Page 5
Ag-1000 user’s manual sms alert gateway all contents are subjected to change without prior notice rev 7.3 page 3 of 27 copyright © 2005 taiko network communications pte ltd functions highlight: 1. To monitor 8 dry contacts and trigger 4 relay outputs, a total of 12 alarm points available; 2. User-de...
Page 6
Ag-1000 user’s manual sms alert gateway all contents are subjected to change without prior notice rev 7.3 page 4 of 27 copyright © 2005 taiko network communications pte ltd section 2 hardware reference 2.1 connector description the figure below shows the front view of sms alert gateway. All the item...
Page 7
Ag-1000 user’s manual sms alert gateway all contents are subjected to change without prior notice rev 7.3 page 5 of 27 copyright © 2005 taiko network communications pte ltd (3) sim card slot a sim card is required for sms alert gateway. The sim card tray can be taken out by pressing on the eject but...
Page 8
Ag-1000 user’s manual sms alert gateway all contents are subjected to change without prior notice rev 7.3 page 6 of 27 copyright © 2005 taiko network communications pte ltd (6) ethernet port (rj45), “lan” this is for ethernet connection. The pin layout is shown as follow: 1: e_tx+ 2: e_tx- 3: e_rx+ ...
Page 9
Ag-1000 user’s manual sms alert gateway all contents are subjected to change without prior notice rev 7.3 page 7 of 27 copyright © 2005 taiko network communications pte ltd that it can be configured in remote area through lan connection. For such application, the ethernet port is connected with ethe...
Page 10
Ag-1000 user’s manual sms alert gateway all contents are subjected to change without prior notice rev 7.3 page 8 of 27 copyright © 2005 taiko network communications pte ltd section 3 web configuration 3.1 login enter the web address of the configuration page in the internet explorer address bar. Ent...
Page 11
Ag-1000 user’s manual sms alert gateway all contents are subjected to change without prior notice rev 7.3 page 9 of 27 copyright © 2005 taiko network communications pte ltd 3.2 main 1 - navigation tab which navigate through pages: • main – main page. • group list – create a hand phone group list of ...
Page 12
Ag-1000 user’s manual sms alert gateway all contents are subjected to change without prior notice rev 7.3 page 10 of 27 copyright © 2005 taiko network communications pte ltd 3.3 group list 1 - navigation tab which navigate through the hand phone list of group 1 to group 8 where group 8 is the admini...
Page 13
Ag-1000 user’s manual sms alert gateway all contents are subjected to change without prior notice rev 7.3 page 11 of 27 copyright © 2005 taiko network communications pte ltd 3.4 point list 1 - navigation tab which navigate through devices: • master • slave 1 • slave 2 2 - navigation tab which naviga...
Page 14
Ag-1000 user’s manual sms alert gateway all contents are subjected to change without prior notice rev 7.3 page 12 of 27 copyright © 2005 taiko network communications pte ltd 3 - point setting • point no. – identification of the point. • alarm state – set the alarm to trigger when in open/close conta...
Page 15
Ag-1000 user’s manual sms alert gateway all contents are subjected to change without prior notice rev 7.3 page 13 of 27 copyright © 2005 taiko network communications pte ltd 3.5 edit profile 1 - to change username. Maximum 15 characters. 2 - to change password. Maximum 15 characters. 3 - to change i...
Page 16
Ag-1000 user’s manual sms alert gateway all contents are subjected to change without prior notice rev 7.3 page 14 of 27 copyright © 2005 taiko network communications pte ltd 3.6 event log provide a web logging features which stores up to 200 logs events. Display records of: – alarm triggered. – sms ...
Page 17
Ag-1000 user’s manual sms alert gateway all contents are subjected to change without prior notice rev 7.3 page 15 of 27 copyright © 2005 taiko network communications pte ltd 3.7 reset setting click “reset master” to reset master device setting to default. All data in group list and point list will b...
Page 18
Ag-1000 user’s manual sms alert gateway all contents are subjected to change without prior notice rev 7.3 page 16 of 27 copyright © 2005 taiko network communications pte ltd section 4 function description 4.1 sms alarming in “alarm group” setting, the interval delay among each hand phone number is c...
Page 19
Ag-1000 user’s manual sms alert gateway all contents are subjected to change without prior notice rev 7.3 page 17 of 27 copyright © 2005 taiko network communications pte ltd ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ example #2: sending alarm sms in escalating sequ...
Page 20
Ag-1000 user’s manual sms alert gateway all contents are subjected to change without prior notice rev 7.3 page 18 of 27 copyright © 2005 taiko network communications pte ltd sending second alarming sms to supervisor 3. If the reminder delay is zero, then alert gateway will escalate sms alarming to s...
Page 21
Ag-1000 user’s manual sms alert gateway all contents are subjected to change without prior notice rev 7.3 page 19 of 27 copyright © 2005 taiko network communications pte ltd 4.2 triggering 2 nd ag1000-01 relay output if a 2nd ag1000-01 is installed far apart, ag1000-01 is able to trigger a relay out...
Page 22
Ag-1000 user’s manual sms alert gateway all contents are subjected to change without prior notice rev 7.3 page 20 of 27 copyright © 2005 taiko network communications pte ltd device 2 - add in the handphone number of device 1 in group 8 (admin) of the group list. Required to be at admin group to trig...
Page 23
Ag-1000 user’s manual sms alert gateway all contents are subjected to change without prior notice rev 7.3 page 21 of 27 copyright © 2005 taiko network communications pte ltd 4.3 remote sms requests besides receiving alarm message in remote area, there are others useful sms functions available for pr...
Page 24
Ag-1000 user’s manual sms alert gateway all contents are subjected to change without prior notice rev 7.3 page 22 of 27 copyright © 2005 taiko network communications pte ltd the service provider of the sim card inserted. Therefore, the alarm condition time is reported correctly. This sms function is...
Page 25
Ag-1000 user’s manual sms alert gateway all contents are subjected to change without prior notice rev 7.3 page 23 of 27 copyright © 2005 taiko network communications pte ltd appendix a: product specifications physical dimension size 130mm x 40mm x 120mm (d x w x h) weight 460g diagnostic leds gsm si...
Page 26
Ag-1000 user’s manual sms alert gateway all contents are subjected to change without prior notice rev 7.3 page 24 of 27 copyright © 2005 taiko network communications pte ltd appendix b: sms message format list sms alarm message format xxx yyy xxx – point name assigned by use; yyy – on message assign...
Page 27
Ag-1000 user’s manual sms alert gateway all contents are subjected to change without prior notice rev 7.3 page 25 of 27 copyright © 2005 taiko network communications pte ltd c xxx failed to acknowledge the acknowledgement failed because either the contact point is not under alarm condition or alarm ...
Page 28
Ag-1000 user’s manual sms alert gateway all contents are subjected to change without prior notice rev 7.3 page 26 of 27 copyright © 2005 taiko network communications pte ltd b service is unavailable now. The request is not accepted if any activated point of gateway was found under alarm condition. S...
Page 29
Ag-1000 user’s manual sms alert gateway all contents are subjected to change without prior notice rev 7.3 page 27 of 27 copyright © 2005 taiko network communications pte ltd appendix c: connection instruction for extended io. The following steps are to connect up the sms alert gateways for io extens...