Tainet Xstream 1300 Series User Manual

Manual is about: MSDSL Termination Unit

Summary of Xstream 1300 Series

  • Page 1

    Tainet xstream 1300 series msdsl termination unit user's manual the professional partner t ainet communic ation system corp. Headquarters: no. 25, alley 15, lane 120, sec. 1. Nei-hu rd, taipei 114, taiwan tel: 886-2-26583000 fax: 886-2-26583232 beijing branch: 3f, a building, 113 zhi chun lu, haidia...

  • Page 3: Fcc Notice

    Fcc notice this equipment has been tested to comply with limits for a class a digital device, pursuant to part 15 of the fcc rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment gener...

  • Page 4: All Right Reserved

    Copyright © 1999 tainet communication system corporation. All right reserved printed in taiwan r.O.C. Notice this document is protected by the international copyright law. No part of this publication may be reproduced by any means without the permission of tainet communication system corporation. Ta...

  • Page 5: Warranty And Service

    Warranty and service contact: if there are any questions, contact your local sales representative, service representative, or distributor directly for any help needed. You might use one of the following methods.. Via the internet: visit our world wide web site at http://www.Tainet.Net via the sales ...

  • Page 7: Contents

    Contents chapter 1 inside the xstream 1300 ...........................................1 1.1 description ...................................................................................2 1.2 features ........................................................................................3 1.3 spec...

  • Page 8

    5.1 overview....................................................................................40 5.2 connection .................................................................................40 5.3 keyboard....................................................................................40 5.4...

  • Page 9

    D-2 digital loop back ......................................................................66 appendix-e factory profiles................................................67 appendix-f software upgrade ............................................69 f-1 overview...........................................

  • Page 10: Figures

    Figures figure 1-1 : cellular network application of the xstream 1300 with g.703 i/f ...... 6 figure 1-2 : campus network application of the xstream 1300 with g.703 i/f ...... 7 figure 1-3 : campus network application of the xstream 1300 with v.35 i/f ........ 7 figure 1-4 : e1 application of the xs...

  • Page 11: Tables

    Tables table 1-1 : specifications of the xstream 1300 ....................................................... 4 table 2-1 : indicators on front panel ............................................................................13 table 2-2 : definition of key on keypad of the xstream 1300...............

  • Page 13: Chapter 1

    Chapter 1 inside the xstream 1300 chapter 1 inside the xstream 1300 overview 1.1 description 1.2 features 1.3 specifications 1.4 applications 1.4.1 cellular network 1.4.2 campus network 1.4.3 e1 network 1.

  • Page 14: 1.1 Description

    Chapter 1 inside the xstream 1300 1.1 description tainet’s xstream 1300 family uses msdsl (multi-rate symmetrical digital subscriber loop) technology to offer the “last mile” transport of repeater less t1/e1 and nx64 kbps circuit between customer facilities and central site equipment. The xstream 13...

  • Page 15: Software Selection.

    Chapter 1 inside the xstream 1300 only one of two interfaces is operational simultaneously via software selection. The xstream 1300 not only offers reliable service but also provides a well-developed network management system. An embedded snmp agent for xstream 1300 fitted to the super shelf at the ...

  • Page 16: 1.3 Specifications

    Chapter 1 inside the xstream 1300 1.3 specifications table 1-1 : specifications of the xstream 1300 dsl modulation 128-cap mode full duplex with echo cancellation number of loops single loop rate 144 kbit/s to 2320 kbit/s data rate 64k to 2304kbit/s (xstream 1310/1330 up to 1040kbps) loop impedance ...

  • Page 17

    Chapter 1 inside the xstream 1300 home & loc/rem status indicators pwr : power indicator cpe : co/cpe indicator dsl : dsl status indicator dte1 : dte1 interface existing indicator dt 2 : dte2 interface existing indicator e sq : signal quality indicator alm : disconnection indicator tst : test status...

  • Page 18: 1.4 Applications

    Chapter 1 inside the xstream 1300 1.4 applications 1.4.1 cellular network the cellular network user will need to lease larger numbers of e1 circuits in order to connect remote cell sites to mobile telephone switching offices (mtsos). Tainet’s xstream 1300 provides an alternative to standard repeater...

  • Page 19

    Chapter 1 inside the xstream 1300 1.4.2 campus network the xstream 1300 is well suited to the campus applications. Figure 1-2 and figure 1-3 show two general campus applications where remote pbx or routers are interconnected across a campus using two xstream 1300. One unit is configured as a central...

  • Page 20

    Chapter 1 inside the xstream 1300 1.4.3 e1 network the xstream 1300 can be deployed to replace tradition e1 network, without the repeater in the e1 network and effectively doubling the utilization of the existing twisted copper pair. Figure 1-4 shows a general e1 network. Figure 1-4 : e1 application...

  • Page 21: Chapter 2

    Chapter 2 interfacing chapter 2 interfacing overview 2.1 front panel 2.1.1 lcd display 2.1.2 top menu 2.1.3 status indicators 2.1.4 keypad 2.2 rear panel 9.

  • Page 22: 2.1 Front

    Chapter 2 interfacing 2.1 front panel the front panel of the xstream 1300 is illustrated in figure 2-1. There are 3 sections included. $ lcd display $ status indicators $ keypad x stream l 2048 kbps co handshaking i rem/loc home xdsl series pwr cpe dsl dte1 dte2 sq alm tst lcd display status indicat...

  • Page 23

    Chapter 2 interfacing 2.1.1 lcd display the lcd display of the xstream 1300 is a 2 by 16 character screen. The xstream 1300 uses it and keypad to perform all system operations. Figure 2-2 shows the lcd display. X stream l 2048 kbps co connected 42i 1300 1300 figure 2-2: the lcd display 2.1.2 top men...

  • Page 24

    Chapter 2 interfacing 1. L : local/remote. Local or remote operating indication. L represents operating in local, and r represents operating in remote. 2. 2048 kbps : speed indication. The item indicates the speed setting if the system is not in data mode. Otherwise, it indicates connection speed. 3...

  • Page 25

    Chapter 2 interfacing table 2-1 : indicators on front panel name description color off flashing 0,5 secs flashing 0,2 secs always on pwr power green no power n/a n/a power ok cpe co/cpe green co n/a n/a cpe dsl loop green idle handshaking / training linked / sync hunting connecting dte1 dte port 1 g...

  • Page 26

    Chapter 2 interfacing table 2-2 : definition of key on keypad of the xstream 1300 rem/loc home go to up layer menu go to down layer menu or decide item move to right menu move to left menu item return to top menu switch menu operation to remote or local if user selects ‘rem/loc’ keypad after connect...

  • Page 27: 2.2 Rear

    Chapter 2 interfacing 2.2 rear panel the following connectors are available: ac receptacle, ground terminal, dsl jack, craft interface, dte1 and dte2 connectors on the rear panel as shown in figure 2-5. Dsl craft dte1 dte2 power 115/230vac 1 2 3 4 5 6 7 figure 2-5a : the rear panel of the xstream 13...

  • Page 28

    Chapter 2 interfacing figure 2-6 : terminal block for g.703 e1 balanced interface figure 2-7 : bnc for g.703 unbalanced interface figure 2-8 : db-25 for v.35 and rs-530 interface 1 8 1 8 figure 2-9: router module 16.

  • Page 29: Chapter 3

    Chapter 3 installation guide chapter 3 installation guide overview 3.1 unpacking 3.2 preliminary preparations 3.3 set up procedures 3.4 configuration procedures 3.4.1 load factory profile 3.4.2 local loop back test 3.4.3 make connection 3.5 trouble report 17.

  • Page 30: 3.1 Unpacking

    Chapter 3 installation guide 3.1 unpacking the xstream 1300’s shipping package includes the following items: ! ! ! ! ! ! A xstream 1300 standalone unit the user’s manual a power cord a 24 awg rj-45 cable a rj-45 cable box optional items % g.703 e1 balanced interface # a g.703 e1 balanced module % g....

  • Page 31: 3.2 Preliminary

    Chapter 3 installation guide 3.2 preliminary preparations to test the xstream 1300’s functions, you need to have the following equipment and accessories. # xstream 1300 terminal unit with dte module x 2 # ber tester x 2 # power cord x 4 # rj-45 twisted cable x 1 # test cable x 2 3.3 set up procedure...

  • Page 32: 3.4 Configuration

    Chapter 3 installation guide 3.4 configuration procedures this section guides the user in some basic operations via front panel and to make sure the xstream 1300 unit is correctly configured. The operations include load factory profile, local loop back test and make connection. 3.4.1 load factory pr...

  • Page 33

    Chapter 3 installation guide 3.4.2 local loop back test 1. Turn on the xstream 1300 and wait for lcd’s screen to show as top indicated : 2. Press down , right 3 times, down , right , down key and the lcd’s screen to show : l 2048 kbps co handshaking i l menu select status l menu select test config l...

  • Page 34: 3.5 Trouble

    Chapter 3 installation guide 3.4.3 make connection 1. Repeat section 3.4.1 steps 1 to 3 for co unit. Press home key and the lcd shows : l 2048 kbps co handshaking i 2. Repeat section 3.4.1 steps 1 to 3 for cpe unit, just select the different profile as lcd shows: l 2048 kbps co handshaking i l menu ...

  • Page 35: Chapter 4

    Chapter 4 system menu operation chapter 4 system menu operation overview 4.1 main menu 4.1.1 submenu tree 4.1.2 the configuration of the xstream 1300 4.1.3 modem config submenu tree 4.1.4 dte config submenu tree 4.1.5 test config submenu tree 4.1.7 status submenu tree 4.1.8 profile submenu tree 23.

  • Page 36: 4.1 Main

    Chapter 4 system menu operation 4.1 main menu the xstream 1300’s menu tree consists of various sub-menus. Users can perform all system operations of the xstream 1300 by using the keypad on front panel and the lcd display. Table 4-1 : definition of key on keypad of the xstream 1300 rem/loc home go to...

  • Page 37

    Chapter 4 system menu operation figure 4-1 : system menu 25.

  • Page 38

    Chapter 4 system menu operation 4.1.1 submenu tree the xstream 1300 has six different sub menu trees as following: # status # modem config # dte config # test config # perf. Monitor # profile each sub-menu contains the individual selectable items. Some of the submenu trees are subject to change with...

  • Page 39

    Chapter 4 system menu operation 4.1.3 modem config submenu tree the xstream 1300 is a standalone terminal unit that can be manually set up by the user. The modem config submenu trees offer the basic configuration for network installation purpose. The operation of the set up procedures requires the b...

  • Page 40

    Chapter 4 system menu operation wetcur description: wetting current to prevent line corrosion. The line selection of status [p.29] is unavailable [n/a] when user turns this selection off. The wetting current selection is fully optional. Options: on turn on the wetting current off turn off the wettin...

  • Page 41

    Chapter 4 system menu operation 4.1.4 dte config submenu tree this submenu tree provides the best solution if the dte equipment cannot connect properly to the xstream 1300. If users experience problems connecting to the dte equipment, a good choice is to modify the dte configuration to meet requirem...

  • Page 42

    Chapter 4 system menu operation rate adaption description: dte clock auto baud rate (co side only) options: follow set-up according to software set up by dte clock specifically by dte clock dte port description data port selection options: dte 1 use the data port 1 (dte1) dte 2 use the data port 2 (...

  • Page 43

    Chapter 4 system menu operation dcd signal [v.35] [rs-530] description: data carrier detector options: normal it is active after connecting force on forces the dcd signal continuously on follow rmt-rts it is active if the remote side of rts signal is active dte2 rxd [v.35f] [rs-530f] description: dt...

  • Page 44

    Chapter 4 system menu operation time slot no [e1] description: specify the number of time slots to be used options: 1 to 31 1 to 31 time slots example: when frame format : framed+crc4 time slot star : 5 time slot no : 4 there are 4 time slots available for data payload (4 x 64 = 256 kbps) when using...

  • Page 45

    Chapter 4 system menu operation 4.1.5 test config submenu tree when user has doubts about network connection, the xstream 1300 provides a group of loop back functions for the user and offers test loop backs to check the conditions of the device status. The loop back functions include the following: ...

  • Page 46

    Chapter 4 system menu operation 4.1.6 perf. Monitor submenu tree when user has doubts about line performance, the xstream 1300 provides a group of performance monitor functions for the e1 and mdsl. Those functionality offer user to measure the performance of the loop in 15 minutes, daily, and thresh...

  • Page 47

    Chapter 4 system menu operation 4.1.7 status submenu tree before or after the configuration set up step, user can monitor the device through the status option of the menu tree. The table of the status submenu can be found in the table 4-5. Table 4-5 : the status submenu items status s/n description:...

  • Page 48

    Chapter 4 system menu operation dte1 description: dte1 port interface type probabilities: not equipped no dte e1 g.703b e1 g.703 balanced interface e1 g.703ub e1 g.703 unbalanced interface router router module interface exist dte interface exist but unknown type dte2 description: dte 2 port interfac...

  • Page 49

    Chapter 4 system menu operation 4.1.8 profile submenu tree use a profile from the manufacturer. For quick configuration steps, it may be helpful and will assist the user to maintain the system as well. The sub-menu tree of the profile is shown in table 4-6 table 4-6 : the profile submenu items profi...

  • Page 51: Chapter 5

    Chapter 5 system terminal operation chapter 5 system terminal operation overview 5.1 overview 5.2 connection 5.3 keyboard 5.4 pop-up boxes 5.5 procedures 5.6 system configuration submenu 5.7 display status submenu 5.8 load profile submenu 39.

  • Page 52: 5.1 Overview

    Chapter 5 system terminal operation 5.1 overview the system terminal may be attached to craft port of the xstream 1300 through the rj-45 jack on rear panel. The craft port is a terminal device with asynchronous protocol supported. On the other hand, the com port interface of the pcs or terminals all...

  • Page 53: 5.4 Pop-Up

    Chapter 5 system terminal operation 5.4 pop-up boxes once an error or any information note has occurred, a pop-up box will appear over the current screen to assist operations. The craft port could assist the system maintenance for a standalone termination unit like the xstream 1300. The pcs or termi...

  • Page 54

    Chapter 5 system terminal operation 3. If the pc’s com port is not the 9-pin of the terminal cable but 25-pin one, the user can change the adapter through correct pin assignments. 4. The main menu screen will display on the pc’s or terminal’s monitor if the connection is successful. (see figure 5-2)...

  • Page 55

    Chapter 5 system terminal operation 5.6 system configuration submenu as mentioned in chapter 3, the configuration is set up via lcd front panel. In this section, the configuration is set up via pcs or terminals. The main menu display on the screen is shown in the figure 5-2. There are three options ...

  • Page 56

    Chapter 5 system terminal operation 5.7 display status submenu when user does configuration of the xstream 1300, he can monitor the system status and parameters via the display status . The basic pop-up menu can be found in the figure 5-4. Figure 5-4 : pop-up menu of the display status the display s...

  • Page 57: 5.8  Load Profile Submenu

    Chapter 5 system terminal operation 5.8 load profile submenu if user has difficulty in configuring the xstream 1300, they can make use of the load profile menu. Figure 5-5 : pop-up menu of the load profile 45.

  • Page 59: Chapter 6

    Chapter 6 router module operation chapter 6 router module operation overview 6.1 description 6.2 lcd menu tree 6.3 the description of the configuration 6.3.1 lan setup 6.3.2 wan setup 6.3.3 ppp setup 6.3.4 frrelay setup 6.3.5 aux setup 6.3.6 routing table 6.3.7 device control 6.3.8 monitor 6.4 how t...

  • Page 60: 6.1 Description

    Chapter 6 router module operation 6.1 description when the xstream 1300 is installed with a router module, an extra function called “router module” will appear on the main menu. Following is the illustration of router module. To install the router module onto xstream 1300, unscrew the cover and firm...

  • Page 61: 6.2  Lcd Menu Tree

    Chapter 6 router module operation 6.2 lcd menu tree lan setup ip address tainet route module ip netmask wan protocol wan setup ppp setup ppp frame relay local ip remote ip ip netmask async - 115200 async - 57600 async - 38400 async - 19200 async - 9600 async - 4800 async - 2400 async - 1200 enter to...

  • Page 62

    Chapter 6 router module operation 6.3 the description of the configuration 6.3.1 lan setup ip address the ip address is a unique 4-byte (32-bit) numeric value used to identify a network and a local host on that network. Each ip address consists of four sets of decimal numbers separated by the period...

  • Page 63

    Chapter 6 router module operation 6.3.4 frrelay setup local ip this parameter identifies the ip address for local wan port when the wan protocol is selected frame relay. Ip netmask wan port ip netmask when the wan protocol is selected frame relay. Remote ip this parameter identifies the ip address f...

  • Page 64

    Chapter 6 router module operation 6.3.7 device control warm start press the “ enter” key to restart the device. Restore default press the “ enter” key to reset the parameters to the factory defaults. 6.3.8 monitor lan rx packets the total number of input packets received from the lan interface. Lan ...

  • Page 65

    Chapter 6 router module operation 6.4 how to operate and setup internet applications host 192.72.240.253 ppp internet service ethernet lan xstream1300 192.72.240.252 192.10.25.1 figure 6-3 : the internet connection over ppp example of setting up the procedures via front panel step 1:under lan setup ...

  • Page 66

    Chapter 6 router module operation host 192.72.240.253 frame relay internet service ethernet lan xstream1300 192.72.240.252 192.10.25.1 figure 6-4 : the internet connection over frame relay example of setting up the procedures via front panel step 1:under lan setup menu: ip address = 192.10.25.1 step...

  • Page 67

    Chapter 6 router module operation 6.5 how to operate and setup intranet applications host ethernet lan host ethernet lan xstream1300 #1 xstream1300 #2 carrier wan 192.72.244.1 192.72.243.1 figure 6-5 : the intranet connection over ppp example of setting up the procedures via front panel 1. Xstream 1...

  • Page 68

    Chapter 6 router module operation 2. Xstream 1300 #2 setup step 1: under lan setup menu: ip address = 192.72.243.1 step 2: under lan setup menu: ip netmask = 255.255.255.0 step 3:under wan setup menu: wan protocol = ppp step 4: under ppp setup menu: local address = 192.72.243.1 step 5: under ppp set...

  • Page 69: Appendix

    Appendix appendix overview appendix-a dte module setting appendix-b order information appendix-c pins assignment c-1 v.35 interface c-2 rs-530 interface c-3 v.36/rs-449 interface c-4 x.21 interface c-5 db-9 interface c-6 rj-45 interface appendix-d loopback d-1 local loop back d-2 digital loop back a...

  • Page 70

    Appendix appendix-a dte module setting on off power module lcd front panel u14 u7 flash u4 u15 u11 cnt1 on dte1 dte2 dte1 dte2 switch module model name dip 1 dip 2 dip 3 dip 4 g703b-3l on on on on g.703 module g703u-3l on on on on router module router-l off on on on reserve dte 1 no equipped off off...

  • Page 71: Appendix-B Order

    Appendix appendix-b order information model name part no description 1300/* 000075-0001 msdsl; up to 2m; standalone basic unit; without dte i/f; up to two dte i/f are supported; 1300d/* 000075-0012 msdsl; up to 2m; standalone basic unit; without dte i/f; up to two dte i/f are supported; dc power dte...

  • Page 72

    Appendix model name part no description 1320/* 000075-0006 msdsl; up to 2m; line card basic unit; dual-port; without dte i/f; /v35-2 000075-0007 dual v.35 i/f; nx64 kbps(n=1..32); with fifo; female; with adaptor cable /r530-2 000075-0009 dual rs-530 i/f; nx64 kbps(n=1..32); with fifo; female /v36-2 ...

  • Page 73: Appendix-C Pins

    Appendix appendix-c pins assignment c-1 v.35 interface table b-1 : v.35 cable pin definition db25 male signal v.35 female source 1 frame ground a common 7 signal ground b common 4 request to send c dte 5 clear to send d dce 6 data set ready e dce 8 data carrier detect f dce 20 data terminal ready h ...

  • Page 74: C-2 Rs-530 Interface

    Appendix c-2 rs-530 interface table c-2 : rs-530 connector pin definition db25 male signal source 1 frame ground common 2 transmit data (a) dte 3 receive data (a) dce 4 request to send (a) dte 5 clear to send (a) dce 6 dce ready (a) dce 7 signal ground common 8 receive line signal detector (a) dce 9...

  • Page 75: C-3 V.36/rs-449 Interface

    Appendix c-3 v.36/rs-449 interface table c-3 : v.36/rs-449 cable pin definition db25 male signal v.36/ rs-449 female source 1 shield 1 common 2 send data (a) 4 dte 15 send timing (a) 5 dce 3 receive data (a) 6 dce 4 request to send (a) 7 dte 17 receive timing (a) 8 dce 5 clear to send (a) 9 dce 6 da...

  • Page 76: C-4 X.21 Interface

    Appendix c-4 x.21 interface table c-4 : x.21 cable pin definition db25 male signal x.21 female 1 shield ground 1 2 signal ground 2 4 txd(a) 3 3 ctrl(a) 4 8 rxd(a) 5 17 indication 6 24 rxc(a) 7 7 signal ground 8 14 txd(b) 9 19 ctrl(b) 10 16 rxd(b) 11 10 indication 12 9 rxc(b) 13 11 exc(b) 14 g g figu...

  • Page 77: C-6  Rj-45 Interface

    Appendix figure c-8 : rj-45 interface c-6 rj-45 interface 1 8 figure c-9 : rj-45 interface table c-6 : dsl rj-45 connector pin definition rj-45 signal 4 tip 5 ring table c-7 : lan rj-45 connector pin definition rj-45 10baset signal 1 txd twist pair + 2 txd twist pair - 3 rxd twist pair + 6 rxd twist...

  • Page 78: Appendix-D Loopback

    Appendix appendix-d loopback d-1 local loop back dte i/f local msdsl system msdsl data pump x figure d-1 : local loop back d-2 digital loop back dte i/f local msdsl system msdsl data pump remote msdsl system msdsl data pump dte i/f x x dsl loop figure d-2 : digital loop back 66.

  • Page 79: Appendix-E Factory

    Appendix appendix-e factory profiles table e-1 : profile setting list 1 (rs-530/v.35) modem config 0-co-2048-int 1-cp-2048-rcv 2-co-2048-dte mode co cpe co tx pwr attenu -3db -3db -3db wercur on off on rising edge normal normal normal disconnect automatic automatic automatic termination hi-z hi-z hi...

  • Page 80

    Appendix table e-2 : profile setting list 2 (g.703 full e1) modem config 3 co-e1-uf-dte 4 cp-e1-uf-rcv 5 co-e1-fr-dte 6 cp-e1-fr-rcv mode co cpe co cpe tx pwr attenu -3db -3db -3db -3db wercur on off on off rising edge normal normal normal normal disconnect automatic automatic automatic automatic te...

  • Page 81: Appendix-F Software

    Appendix appendix-f software upgrade f-1 overview the xstream 1300 uses a flash memory as the system rom, and it provides the software upgrade function. There are 2 steps to execute the software upgrade function : # download the software via the craft port from the pcs or terminal program to the xst...

  • Page 82: F-4  Flash Download

    Appendix 1300’s craft port and pc’s com port). 3. If the pc’s com port is not the 9-pin of the terminal cable but 25-pin one, the user can change the adapter through correct pin assignments. 4. Turn off the xstream 1300. 5. Presses the up, right, left three keys at same time. 6. Turn on the xstream ...

  • Page 83: Company

    Appendix appendix-g trouble report company local representation purchase order no equipment serial no software version please describe: 1. Testing network structure 2. Configuration 3. Testing network equipment 4. Trouble description e-mail : tel : fax : signature : date : / / 71.

  • Page 84: Sales@tainet.Net

    Appendix tainet communication system corp. Fax : 886-2-2658-3232 e-mail : # sales@tainet.Net 72.

  • Page 85: Appendix-H   Glossary

    Appendix appendix-h glossary dte1........................... 1-5, 2-4, 4-13 a dte2........................... 1-5, 2-4, 4-13 about this manual ............... Iii dte2 rxd....................................4-9 alm...................................... 1-5, 2-4 e applications ..........................

  • Page 86

    Appendix load profile .........................A-7 loc/rem ................................... 1-5 local loopback test ................... 3-5 loop impedance .......................... 1-4 m main menu .................................. 4-2 make connection ........................ 4-6 mode .............