    Pb 1 taiyo electric ind.Co.,ltd. Temperature controlled lead-free soldering station rx-802as thank you for buying a goot soldering station. Your new soldering station has been engineered and manufactured to the goot high standards for dependability, ease of operation, and operator safety. If you fol...

  • Page 2: Warning

    Taiyo electric ind.Co.,ltd. Taiyo electric ind.Co.,ltd. 2 warning failure to obey a safety warning could result in serious injury or death to yourself or to others. Always follow the safety precautions to reduce the risk of electric shock, fire or personal injury. Caution failure to obey a safety ca...

  • Page 3: 1  Table of Contents

    3 taiyo electric ind.Co.,ltd. 3 1 table of contents 1. Table of contents / specifications ......................................................................3 2. Introduction ...........................................................................................4 2.1 unpacking ..................

  • Page 4: 2-1  Unpacking

    Taiyo electric ind.Co.,ltd. Rx-802as operation manual soldering iron stand : st-21 control unit soldering unit : rx-80gas packing list ■ control unit ■ soldering unit : rx-80gas ■ soldering iron stand :st-21 ■ operation manual please make sure that all the items listed below are included, and that t...

  • Page 5: Front View

    5 taiyo electric ind.Co.,ltd. 5 taiyo electric ind.Co.,ltd. Key lock rx-802 heat sleep temp. ˚c as front view side view operation panel cover power cord rating label power switch tip (sold separately) slide lever grip rubber soldering unit connector grip adapter output terminal for soldering unit 2-...

  • Page 6: Rx-802

    Taiyo electric ind.Co.,ltd. 6 taiyo electric ind.Co.,ltd. Key lock rx-802 heat sleep temp. ˚c as ① ⑤ ⑥ ③ ② ④ ⑦ ⑧ ⑨ 1. Heat lamp lights up when the heater is on. 2. Sleep lamp flashes while setting the sleep function. The flashing of the sleep lamp will increase 30seconds before entering sleep mode. ...

  • Page 7: Warning

    Taiyo electric ind.Co.,ltd. 6 taiyo electric ind.Co.,ltd. 7 rub the soldering-iron tip on the moistened sponge. Use the hole of the sponge for better cleaning. Alternatively, push the soldering-iron tip in and out of the brass wool a few times. Stab, not swipe. Front opening adjusting screws heat-re...

  • Page 8: 3  Rules For Safe Operation

    Taiyo electric ind.Co.,ltd. Taiyo electric ind.Co.,ltd. 8 3 rules for safe operation 1. Do not use in dangerous environments. Do not use the soldering station in damp or wet locations or expose it to external environmental conditions, particularly rain. Never use it in an explosive atmosphere. The h...

  • Page 9

    9 taiyo electric ind.Co.,ltd. 9 taiyo electric ind.Co.,ltd. 7. Use stand provided. Be sure to use the st-21 soldering iron stand included with the soldering station. If this stand is not used, the plastic parts (adapter ring and/or handpiece) of the soldering iron unit could be damaged. Position the...

  • Page 10: Key Operation

    Taiyo electric ind.Co.,ltd. Taiyo electric ind.Co.,ltd. 10 4 1 2 3 key operation temp display note ) if nothing is pressed for 30seconds during setting the temperature, the temperature on display will be recorded and the display will return to the normal conditions. *the set temperature should be se...

  • Page 11: Key Operation

    11 taiyo electric ind.Co.,ltd. 11 1 2 3 how to set the tip no. Rx-80hrt-b is mounted in the standard unit. When changing to a different type of tip, the calibration of the tip temperature is required before starting soldering work. Otherwise, there may be a difference between the actual tip temperat...

  • Page 12: Key Operation

    Taiyo electric ind.Co.,ltd. 12 taiyo electric ind.Co.,ltd. 1 2 4 how to calibrate the temperature the rx-802as can be calibrated using a tip thermometer. Generally speaking, when measuring the tip temperature of the rx-802as with a standard tip thermometer, the measured temperature will usually be l...

  • Page 13: 4-4  Sleep Function

    Taiyo electric ind.Co.,ltd. 12 taiyo electric ind.Co.,ltd. 13 the sleep start timer (ct) function automati- cally lowers the temperature of the tip after a preset period of inactivity. This function reduc- es power consumption and helps extend sol- dering tip life. This sleep function can be used wi...

  • Page 14: Key Operation

    Taiyo electric ind.Co.,ltd. 14 taiyo electric ind.Co.,ltd. 1 2 4 setting the sleep start time (ct) unit: mins. Key operation temp display 3 by setting the ct (sleep start time) to 0.00 the sleep function will be turned off and the sleep lamp will go out. Set to 5 minutes before shipping. Example : c...

  • Page 15: Key Operation

    Taiyo electric ind.Co.,ltd. 14 taiyo electric ind.Co.,ltd. 15 1 2 4 setting the sleep sensitivity (dif) unit : °c key operation temp display 3 example : changing the sleep sensitivity value to 2 °c (3.6°f) to 3.0°c (5.4°f). Press and hold the key for over 3 seconds continuously. Press the key four t...

  • Page 16: Key Operation

    Taiyo electric ind.Co.,ltd. 16 taiyo electric ind.Co.,ltd. When the unit is not operated during the preset time, the unit is automatically shutdown. Even if the user forgets to turn off the unit, this shutdown function works to keep the unit inactive, and prevents accidents such as fire. 4-5 setting...

  • Page 17: Key Operation

    Taiyo electric ind.Co.,ltd. 16 taiyo electric ind.Co.,ltd. 17 the rx-802as sounds an alarm, when the soldering iron is left in contact with the component being soldered past the time set. This function prevents inexperienced operators from overheating the component. 4-6 setting the soldering-time al...

  • Page 18: Key Operation

    Taiyo electric ind.Co.,ltd. 18 taiyo electric ind.Co.,ltd. 1 2 4 setting the alarm range key operation temp display the upper limit and the lower limit are set to 50˚c respectively, before shipping 3 display “h” or “l”, by pressing the key. Key. Press and hold the key for over 3 seconds continuously...

  • Page 19: Key Operation

    Taiyo electric ind.Co.,ltd. 18 taiyo electric ind.Co.,ltd. 19 returns to the set temperature display. 1 2 4 setting the alarm sound this setting switches the alarm on and off. The initial setting is on (the alarm sounds). Set to off for mute (no sound). Key operation temp display 4-8 setting the ala...

  • Page 20: Key Operation

    Taiyo electric ind.Co.,ltd. 20 taiyo electric ind.Co.,ltd. The temperature can be viewed in celsius or in fahrenheit. The temperature display is set to celsius (˚c) before shipping. 4-9 setting the temperature display 1 2 4 key operation temp display 3 press the key ten times. Press and hold the key...

  • Page 21: 4-10  Key Lock Function

    Taiyo electric ind.Co.,ltd. 20 taiyo electric ind.Co.,ltd. 21 the key lock function locks the temperature and parameter settings. Therefore the temperature and parameters cannot be changed by any unauthorized personnel. Authorized personnel may use a code number to set, or release the key lock funct...

  • Page 22: Key Operation

    Taiyo electric ind.Co.,ltd. 22 taiyo electric ind.Co.,ltd. 1 6 key operation temp display 3 2 4 5 displays alternately how to change the code number displays alternately press the key. Press and hold the example : when changing the code number from 123 to 234. For over 3 seconds continuously. Press ...

  • Page 23: Key Operation

    Taiyo electric ind.Co.,ltd. 22 taiyo electric ind.Co.,ltd. 23 if you forget the code number, follow the procedure below to delete the code number and reset the key lock. This procedure releases the key lock function which means that unauthorized persons can change temperature and/or parameter settin...

  • Page 24: Key Operation

    Taiyo electric ind.Co.,ltd. 24 taiyo electric ind.Co.,ltd. 4-11 how to restore default settings 1 key operation temp display 2 press these the following keys simultaneously for over 5 seconds, while the preset temperature display is shown. All settings are restored to the factory default. The preset...

  • Page 25

    Taiyo electric ind.Co.,ltd. 24 taiyo electric ind.Co.,ltd. 25.

  • Page 26: 5  Maintenance

    26 taiyo electric ind.Co.,ltd. 26 5 maintenance caution the soldering unit is designed so the tip can be replaced without turning off the power. However, the tip is very hot. Do not touch the tip or serious burns may result. The removed tip should be placed in the hole in the iron stand tip end firs...

  • Page 27: 5-3  Housing Cleaning

    26 27 2. Remove the old grip rubber and replace with new one. Taiyo electric ind.Co.,ltd. Taiyo electric ind.Co.,ltd. 27 recommended temperature the lead-free soldering iron should be set at a low temperature. This slows down carbon- ization. Lead-free soldering irons have excel- lent heat recovery....

  • Page 28: 6  Troubleshooting

    28 what to do when the tip is blackened and not ‘wettable’ using a clean sponge, repeat the process of ’tinning’ and ‘cleaning’ the tip several times. The tip surface of an iron that has been in use a short time, generally has a higher ‘wettability’ recovery level. If this does not remove the discol...

  • Page 29: 7  Replacement Tips

    28 29 taiyo electric ind.Co.,ltd. Taiyo electric ind.Co.,ltd. 29 7 replacement tips rx-80hrt-b rx-80hrt-2b rx-80hrt-sb rx-80hrt-lb φ4.7 8.5 4.5 r0.3 φ4.7 10 3 r0.6 φ4.7 9 2.5 r0.15 rx-80hrt-lb ¥1,575 (税別¥1,500) φ4.7 12.7 5 r0.3 rx-80hrt-lbj rx-80hrt-bm rx-80hrt-1bc rx-80hrt-2.3bc 12 30˚ 5 φ4.7 8.5 4...

  • Page 30: Replacement Parts

    Taiyo electric ind.Co.,ltd. 30 taiyo electric ind.Co.,ltd. 8 replacement parts for replacement parts, contact a goot distributor. No. Item parts no. Note 1 rx-802as soldering unit rx-80gas tip is not included 2 soldering iron stand st-21 stand for rx-8 series 3 soldering iron stand sponge st-53sp re...

  • Page 31: 9  Parameters

    31 taiyo electric ind.Co.,ltd. 9 parameters term (display panel letters) display panel unit range shipping default setting set temperature (pt) ˚c ˚f (sst + 50) — 450 (sst + 90) — 842 250 482 tip number (tpn) — 0—5 1 temperature calibration (cal) ˚c ˚f -50—50 -90—90 0 0 sleep set temp (sst) ˚c ˚f 0—...

  • Page 32

    Taiyo electric ind.Co.,ltd. Soldering equipment and accessories taiyo electric ind.Co.,ltd. Customer service: contact your nearest distributor goot is registered trade mark of taiyo electric ind.Co.,ltd. Printed in japan july 2014 a1220my00 aob homepage: www.Goot.Co.Jp e-mail: info@goot.Co.Jp.