Takagi 510 Outdoor (T-D2-OS) Installation Manual And Owner's Manual - General

Manual is about: On-Demand Water Heater

Summary of 510 Outdoor (T-D2-OS)

  • Page 1

    ‐ do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. ‐ what to do if you smell gas • do not try to light any appliance. • do not touch any electric switch, do not use any phone in your building. • immediately call your gas supplier from...

  • Page 2: Installation

    Contents 2 │ page contents specifications…………………………………………………………………………………………..………………………... Introduction…………………………………………………………………………………………………..…………………. Safety guidelines…………….………………………………………………………………………………………..……….. Installation………………………………………………………………………………………………..…………………..…. General……………………………………………...

  • Page 3

    Specifications 3 │ page specifications model t ‐ kjr2 ‐ in t ‐ kjr2 ‐ os t ‐ k4 ‐ in t ‐ k4 ‐ os t ‐ d2 ‐ in t ‐ d2 ‐ os natural gas input (operating range) min: 19,500 btu/h max: 140,000 btu/h min: 11,000 btu/h max: 190,000 btu/h min: 11,000 btu/h max: 199,000 btu/h propane input (operating range) ...

  • Page 4

    Introduction 4 │ page introduction *this diagram illustrates tankless water heater design concepts only and does not accurately represent to the water heater’s physical description. • this manual provides information necessary for the installation, operation, and maintenance of the water heater. • t...

  • Page 5: Safety

    Safety guidelines 5 │ page • water temperatures over 125°f (52°c) can cause severe burns instantly or death from scalding. The water temperature is set at 122°f (50°c) from the factory to minimize any scalding risk. Before bathing or showering always check the water temperature. • do not store or us...

  • Page 6: General

    Installation 6 │ page installation general 1. Follow all local codes, or in the absence of local codes, follow the most recent edition of the national fuel gas code: ansi z223.1/nfpa 54 in the usa or can/csa b149.1 natural gas, propane installation code in canada. 2. All gas water heaters require ca...

  • Page 7

    Installation 7 │ page • installation and service must be performed by a qualified installer (for example, a licensed plumber or gas fitter), otherwise the warranty will be void. • the installer (licensed professional) is responsible for the correct installation of the water heater and for compliance...

  • Page 8: Clearances

    Installation 8 │ page clearances model top bottom front back sides t ‐ kjr2 ‐ in* 12” 12” 24” 1” 2 “ t ‐ kjr2 ‐ os 36” 12” 24” 1” 2 “ model top bottom front back sides t ‐ k4 ‐ in* 12” 12” 24” 1” 2 “ t ‐ k4 ‐ os 36” 12” 24” 1” 2 “ model top bottom front back sides t ‐ d2 ‐ in* 12” 12” 24” 1” 2 “ t ‐...

  • Page 9: Optional

    Installation 9 │ page optional items model t ‐ kjr2 ‐ in t ‐ kjr2 ‐ os t ‐ k4 ‐ in t ‐ k4 ‐ os t ‐ d2 ‐ in t ‐ d2 ‐ os tk ‐ re02 ✔ ✔ ✔ ✔ tm ‐ re30 ✔ ✔ tk ‐ bf01 ✔ ✔ ✔ tk ‐ tv10 ✔ ✔ ✔ tk ‐ pc01 ✔ ✔ ✔ ✔ tk ‐ pcjr2 ✔ ✔ tk ‐ rb02 ✔ ✔ ✔ tk ‐ kpwl4 tk ‐ kpwh4 ✔ ✔ ✔ tk ‐ kpct43 ✔ ✔ ✔ 1. Temperature remote ...

  • Page 10

    Installation 10 │ page 5. Pipe covers: tk ‐ pc01 and tk ‐ pcjr2 the pipe cover protects the plumbing pipes to the water heater from unexpected adjustments. This pipe cover is fixed to the bottom of the water heater, which hides the plumbing and improves the visual aspects of the whole installation f...

  • Page 11: High

    Installation 11 │ page • do not adjust any dipswitches on the right bank for the t ‐ d2 ‐ in/os models. • the dark squares indicate the direction the dipswitches should be set to. Dipswitches high ‐ altitude installations check the elevation where your water heater is installed. Set dipswitches show...

  • Page 12: Venting

    Installation 12 │ page improper venting of this appliance can result in excessive levels of carbon monoxide which can result in severe personal injury or death. Improper installation can cause nausea or asphyxiation, severe injury or death from carbon monoxide and flue gases poisoning. Improper inst...

  • Page 13: ‐

    Installation 13 │ page ‐ exhaust venting ‐ (for the t ‐ kjr2 ‐ in, t ‐ k4 ‐ in, & t ‐ d2 ‐ in models) this is a category iii appliance and must be vented accordingly. The vent system must be sealed air tight. All seams and joints without gaskets must be sealed with high heat resistant silicone seala...

  • Page 14

    Installation 14 │ page *backflow preventer (recommended for freezing weather conditions: 36°f and below) **vertical condensation drain must be installed accordance with local codes. Horizontal installation diagram with direct ‐ vent concentric termination horizontal installation diagram (with direct...

  • Page 15: ‐

    Installation 15 │ page ‐ vent termination clearances ‐ canada u.S.A direct vent and other than direct vent direct vent other than direct vent a clearance above grade, veranda, porch, deck, or balcony. 1 foot 1 foot 1 foot b clearance to window or door that may be opened. 3 feet 1 foot 4 feet from be...

  • Page 16

    Installation 16 │ page please follow all local and national codes in regards to proper termination clearances. In the absence of such codes, the following clearances can be used as guidelines. Local codes supersede these guidelines. For sidewall terminations exhaust termination 1ft. 1ft. 2ft. Inside...

  • Page 17: Gas

    Installation 17 │ page size the gas pipe appropriately to supply the necessary volume of gas required for the water heater using ansi233.1/nfpa 54 in the usa or can/csa b149.1 in canada or local codes. Otherwise, flow capabilities and output temperatures will be limited. • check that the type of gas...

  • Page 18: ‐

    Installation 18 │ page ‐ natural gas supply piping ‐ maximum delivery capacity of cubic feet of gas per hour of ips pipe carrying natural gas of 0.60 specific gravity based on pressure drop of 0.5” wc based on energy content of 1,000 btu/cubic ft.: the water heater requires 140 cubic ft./hr for the ...

  • Page 19: ‐

    Installation 19 │ page 1. Turn off all electric power to the water heater if service is to be performed. 2. Turn the manual gas valve located on the outside of the unit clockwise 3 to the off position. ‐ measuring inlet gas pressure ‐ the water heater cannot perform properly without sufficient inlet...

  • Page 20: Water

    Installation 20 │ page • do not use this water heater if any part has been submersed under water. Immediately call a licensed professional to inspect the water heater to replace any damaged parts. • do not reverse the hot outlet and cold inlet connections to the water heater. This will not properly ...

  • Page 21: Electrical

    Installation 21 │ page follow the electrical code requirements of the local authority having jurisdiction. In the absence of such requirements, follow the latest edition of the national electrical code ansi/nfpa 70 in the u.S. Or the latest edition of csa c22.1 canadian electrical code, part 1, in c...

  • Page 22: Remote

    Installation 22 │ page remote controller connections to connect the remote controller to the water heater> 1. Disconnect power supply from the water heater. 2. Take off the water heater’s front cover. 3. Locate the remote controller terminal, pictured below (located around the lower right ‐ hand sid...

  • Page 23: Pump

    Installation 23 │ page in an easy ‐ link system, the pump must be connected to the “pump” connector in the “parent” unit only. If the pump is connected to any of the “child” units , the pump will not work. Pump control mode (only available on the t ‐ d2 ‐ in/os models) the t ‐ d2 ‐ in/os water heate...

  • Page 24: Easy

    Installation 24 │ page • the easy ‐ link system is limited up to 4 units . If you connect more than 4 units, only the first 4 units will work as a part of the easy ‐ link system. The other additional units will not work. • all units within an easy ‐ link system must be of the same exact model. Diffe...

  • Page 25

    Installation 25 │ page the dark squares indicate the direction the dipswitches should be set to. 4. Between the “ parent ” and the “ child ‐ 1 ” units connect the “parent” connector of the “parent” unit to the “[1]” connector of the “child ‐ 1” unit. 5. Between the “ child ‐ 1 ” and the “ child ‐ 2 ...

  • Page 26

    Installation 26 │ page • a remote controller is not required for the easy ‐ link system. • if running the easy ‐ link system without a remote controller, please make sure the temperature settings on all the units are set to the same settings. Otherwise, the units will not operate properly. • if a re...

  • Page 27

    Installation 27 │ page connecting two “ parent” connectors together from two separate units may damage the computer board . The communication cable has a female end and a male end so it’s impossible to have a parent ‐ to ‐ parent connection with the communication cable. Do not splice or modify conne...

  • Page 28: ‐

    Installation 28 │ page • in order to purge air in water pipes within a closed ‐ loop system, an air vent and air separator should be installed in to the system. Required circulation flow rates are labeled next to each application diagram. These flow rate requirements must be followed. • toxic chemic...

  • Page 29: ‐

    Installation 29 │ page ‐ dual ‐ purpose hot water heating ‐ (domestic and space heating): • priority control devices such as a flow switch, an aquastat or other electronic controller can be used to prioritize the domestic water system over the heating system. • follow all local codes, or in the abse...

  • Page 30: For

    Initial operation 30 │ page • check the gas and water connections for leaks before firing unit for the first time. • open the main gas supply valve to the unit using only your hand to avoid any spark. Never use tools. If the knob will not turn by hand, do not try to force it; call a qualified servic...

  • Page 31: For

    Operating safety 31 │ page operating safety for your safety read before operating warning: if you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This water heater does not have a pilot. It is equipped with an igni...

  • Page 32: Danger

    Operating safety 32 │ page danger vapors from flammable liquids will explode and catch fire causing death or severe burns. Do not use or store flammable products such as gasoline, solvents or adhesives in the same room or area near the water heater. Keep flammable products: 1. Far away from heater 2...

  • Page 33: General

    Normal operation 33 │ page • flow rate to activate the water heater : 0.75 gallon per minute • flow rate to keep the water heater running : 0.4 gallon per minute • hot water temperatures over 125 ° f (52°c) can cause severe burns instantly or death from scalding. • the outlet hot water temperature o...

  • Page 34: ‐

    Normal operation 34 │ page • do not set to 185 °f if you use your water heater in a recirculation system. This will cause damage to the heater and void the warranty. (this temperature setting is only available on the t ‐ d2 ‐ in/os models) • do not adjust the left bank of dipswitches. (for the t ‐ d...

  • Page 35: Flow

    Normal operation 35 │ page only pipes within the water heater are protected by the freeze protection system. Any water pipes (hot or cold) located outside the unit will not be protected. Properly protect and insulate these pipes from freezing. Household flow rates taken from upc 2006 taken from upc ...

  • Page 36: Maintenance

    Normal operation 36 │ page turn off the electrical power supply and close the manual gas shutoff valve and the manual water control valve before servicing. Maintenance and service • clean the cold ‐ water inlet filter. (refer to diagram below) • be sure that all openings for combustion and ventilati...

  • Page 37: General

    Troubleshooting 37 │ page general troubleshooting ‐ temperature and amount of hot water ‐ problem solutions it takes long time to get hot water at the fixtures. • the time it takes to deliver hot water from the water heater to your fixtures depends on the length of piping between the two. The longer...

  • Page 38

    Troubleshooting 38 │ page ‐ water heater ‐ problem solutions unit does not ignite when water goes through the unit. • is the flow rate over 0.75 gpm? (p. 33) • check for the filter on cold water inlet. (p. 36) • check for reverse connection and cross connection. • if you use the remote controller, i...

  • Page 39: Error

    Troubleshooting 39 │ page error codes • the units are self diagnostic for safety and convenience when trouble shooting. • if there is a problem with the installation or the unit, depending on the model or if there is a remote controller installed, it will either display a numerical error code on the...

  • Page 40: ‐

    Troubleshooting 40 │ page ‐ fault analysis of error codes ‐ t ‐ kjr2 ‐ in/os & t ‐ k4 ‐ in/os t ‐ d2 ‐ in/os malfunction description diagnosis red led re02 re30 one time 03 031 incorrect dipswitch setting • check the dipswitch settings on the pcb. (part #701) five times 10 101 warning for the “991” ...

  • Page 41

    Troubleshooting 41 │ page t ‐ kjr2 ‐ in/os & t ‐ k4 ‐ in/os t ‐ d2 ‐ in/os malfunction description diagnosis red led re02 re30 n/a n/a 441 flow sensor failure (easy ‐ link system only) • check for connection/breakage of wires and/or debris on the flow sensor impeller. (part #402, 717) six times 51 5...

  • Page 42

    Components diagram 42 │ page components diagram case assembly t ‐ kjr2 ‐ in t ‐ kjr2 ‐ os t ‐ k4 ‐ in & t ‐ d2 ‐ in t ‐ k4 ‐ os & t ‐ d2 ‐ os 0 0 2 0 5 0 7 0 2 0 5 2 0 0 7 7 0 4 0 0 6 0 0 5 0 5 3 0 6 6 0 5 3 0 5 2 0 5 2 0 0 1 0 0 4 0 5 6 0 0 4 0 0 1 0 0 2 0 5 0 7 0 2 0 5 2 0 0 7 7 0 4 0 0 6 0 0 5 0 ...

  • Page 43

    Components diagram 43 │ page 1 0 6 1 0 7 1 0 8 1 0 9 1 1 0 0 6 5 7 1 2 7 0 1 0 5 3 1 2 0 0 5 3 7 1 2 7 1 1 0 5 3 7 1 4 0 6 2 0 5 5 1 1 9 1 5 1 1 1 8 0 5 2 1 2 1 7 0 3 0 5 3 7 0 4 7 0 5 4 0 1 1 0 4 1 0 5 1 0 1 7 0 9 1 1 1 0 5 2 0 5 3 1 1 2 1 1 3 1 1 4 7 0 8 0 5 3 0 6 7 0 5 5 0 5 3 7 0 6 0 5 3 0 5 9 1...

  • Page 44

    Components diagram 44 │ page t ‐ k4 ‐ in/os & t ‐ d2 ‐ in/os fan motor section for os models power control section burner assembly fan motor section for in models manifold assembly 1 1 6 1 1 7 0 5 3 1 0 3 0 5 4 1 1 5 0 5 7 0 5 8 7 1 3 1 0 6 1 0 7 1 0 8 1 0 9 1 1 0 0 6 5 7 1 2 1 2 1 7 0 3 0 5 3 7 0 6...

  • Page 45

    Components diagram 45 │ page water way assembly t ‐ kjr2 ‐ in/os t ‐ k4 ‐ in/os t ‐ d2 ‐ in/os t ‐ kjr2 ‐ in/os & t ‐ k4 ‐ in/os t ‐ d2 ‐ in/os 7 0 7 7 1 0 7 0 8 7 1 5 1 0 3 7 1 7 7 1 8 7 0 1 7 0 9 7 1 9 7 1 6 7 0 1 7 0 7 7 0 9 7 1 4 7 1 0 7 0 8 1 0 3 4 0 2 4 0 2 4 0 7 4 0 8 7 1 9 computer board ass...

  • Page 46

    Output temperature chart 46 │ page parts list item# description part# item# description part# 001 case assembly for t ‐ kjr2 ‐ in for t ‐ kjr2 ‐ os for t ‐ k4 ‐ in & t ‐ d2 ‐ in for t ‐ k4 ‐ os & t ‐ d2 ‐ os ek415 ek432 ek402 ekk41 101 burner assembly for t ‐ kjr2 ‐ in/os burner assembly for t ‐ k4 ...

  • Page 47

    Output temperature chart 47 │ page item# description part# item# description part# 118 119 120 gas inlet gas inlet ring igniter plate ekk1e ekk2z ekk1b 412 hi ‐ limit switch for t ‐ kjr2 ‐ in/os & t ‐ k4 ‐ in/os hi ‐ limit switch for t ‐ d2 ‐ in/os em212 ekn34 121 surge box plate for t ‐ kjr2 ‐ in/o...

  • Page 48

    Output temperature chart 48 │ page output temperature chart output temperature vs. Gpm (max. 6.6 gpm) with various inlet water temperature 0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 o u t p u t h o t w a ter g p m 40 f 50 f 60 f 70 f 40 f 3.8 3.5 3.3 3.1 2.9 2.7 2.5 2.4 2.3 2.1 1.9 1.8 50 f 4.6 4.2 3.8 3.5 3.3...

  • Page 49

    Output temperature chart 49 │ page output temperature vs. Gpm (max. 8.0 gpm) with various inlet water temperature 0.0 2.0 4.0 6.0 8.0 10.0 o u t p u t h o t w a ter g p m 40 f 50 f 60 f 70 f 40 f 5.2 4.8 4.4 4.1 3.9 3.7 3.5 3.3 3.1 2.8 2.6 2.5 50 f 6.2 5.7 5.2 4.8 4.4 4.1 3.9 3.7 3.5 3.1 2.8 2.7 60 ...

  • Page 50

    Warranty 50 │ page product registration and limited warranty 1. Product registration card or form: the enclosed product registration card must be completed and returned within 45 days of original purchasing date by retail buyer. Copy of proof of original purchasing date must be sent in with the regi...

  • Page 51

    Warranty 51 │ page (1) heat exchanger (2) an on ‐ demand recirculation system is a system that utilizes either a push ‐ button or other type of manual activation (as opposed to automatic activation with a temperature sensor or timer) to activate the circulation pump. An on ‐ demand recirculation sys...

  • Page 52

    Warranty 52 │ page • introduction of untreated or poorly treated well water into the product. • introduction of water with ph levels less than 6.5 and greater than 8.5 into the product. 59g099-1.