Takenaka System TL-2048UFD Instruction Manual - page 8
8 / 9
TL-2048UFD Timing chart
【
Line period exposure
】 EXP switch:0
Ext_SYNC
Ext_CLK
Delay time of SYNC_OUT against Ext_SYNC↑:44clk
SYNC_OUT(
Φ P)
SYNC width:10clk
CLK_OUT
DATA_OUT
Effective pixel start:42clk
【
Fixed time exposure
】 EXP switch:1~E
Ext_SYNC
Ext_CLK
Φ A
12clk
10clk
Exposure time
Exposure time:25.6us x N+40clk
SYNC_OUT(
Φ P)
SYNC width:10clk
Delay time of SYNC_OUT against Ext_SYNC↑:25.6us x N+40clk+10clk
CLK_OUT
DATA_OUT
Effective pixel start:42clk
【
Pulse width exposure
】 EXP switch:F
Ext_SYNC
Ext_CLK
Φ A
12clk
6clk
Exposure time
Exposure time:H period of Ext_SYNC+40clk-6clk
SYNC_OUT(
Φ P)
SYNC width:10clk
Delay time of SYNC_OUT against Ext_SYNC↑:40clk
CLK_OUT
DATA_OUT
Effective pixel start:42clk
*・・・Time data are measured values at 40MHz data rate.
It depand on CLK period.
N:Setup value on EXP switch on the rear panel(1~E (Decimal:1~14))
Measuring condition
・
Ext-SYNC is synchronized with Ext-CLK.
・
Ext-CLK:40MHz input(Intra-camera CLK:20MHz)