TALESUN TP536M-100 Installation Manual

Manual is about: TP672 Series; TP660 Series; TP654 Series; TP636 Series; TP596 Series; TP572 Series; TP536 Series crystalline solar photovoltaic modules

Summary of TP536M-100

  • Page 1

    1. Introduction 1.1 purpose of the manual ...................................................................... 2 1.2 disclaimer of liability .......................................................................... 2 1.3 production identification .....................................................

  • Page 2

    1 introduction 1.1 purpose of the manual this guide contains information on precautions to be used during the handling and installation of talesun solar co., ltd photovoltaic modules along with technical instructions to be followed during installation, mounting, wir- ing and maintenance thereof. Tal...

  • Page 3

    1.3 production identification each module has three labels that provide the following information: · nameplate: describes the product type; rated power, rated current, rated voltage, open circuit voltage, short circuit current, all as measured under standard test conditions; weight, dimension etc.; ...

  • Page 4

    Warning! Danger of injury due to broken glass! Risk of injury due to falling modules! The modules are primarily made of glass and must therefore be handled with appropriate caution. · in order to ensure safe mounting, familiarize yourself with all applicable national regulations for work safety and ...

  • Page 5

    3 mechanical installation 3.1 selecting the location · the modules are certified according to the norm iec 61215 and others for safe operation in moderate climates. · do not expose the modules to chemicals. · do not place the modules in standing water. The junction box is splash-proof only. · do not...

  • Page 6

    Ground mount · select the height of the mounting system to prevent the lowest edge of the module from being covered by snow for a long time in winter in areas that experience heavy snowfalls. · in addition, assure the lowest portion of the module is placed high enough so that it is not shaded by pla...

  • Page 7

    Method b: clamping installation · modules can be installed with clamps. Modules must be securely attached to the mounting structure with four clamps on the short frame. · the modules must be properly secured to their support so that they can with stand live load condition, including wind up lift, to...

  • Page 8

    Module type cell type cell q’ty dimensions (mm) a*b j k m n o* p* tp672 series 6inch crystalline (m/p) 6*12 1960*990 50 600 12 20 0.5~2 2.5~3 tp660 series 6inch crystalline (m/p) 6*10 1640*990 50 425 12 20 0.5~2 2.5~3 tp654 series 6inch crystalline (m/p) 6*9 1482*990 50 380 12 20 0.5~2 2.5~3 tp636 s...

  • Page 9

    Wind/snow load · the modules have been designed to resist a static load of 5400 pa (positive load). · when using a insertion system on a short frame without additional support-rail, the modules have been designed to resist a static load of 2400 pa. · this resistance value can decrease if modules are...

  • Page 10

    4.4 grounding: · although the modules are certified to safety class ii, it is recommended that they be grounded and the module installation complies with all local electrical codes and regulations. · the earth grounding connection should be made by a qualified electrician. · connect module frames to...

  • Page 11

    5.1 maintenance talesun modules are built to last and require minimal maintenance. The dirt is typically washed away by rain. However, rain may not adequately clear more stubborn grime (i.E. Pollen, vegetation, bird droppings, etc.). Such soiling which shades the active area of the module can lead t...

  • Page 12

    Model maximum system voltage (v) pmax (w) vmpp (v) impp (a) voc (v) isc (a) fuse rating (a) tp672m-315; 1000(iec) 315 37.3 8.45 46.0 8.87 15 tp672m-310; tp672m-310b 1000(iec) 310 36.9 8.40 45.8 8.83 tp672m-305; tp672m-305b 1000(iec) 305 36.5 8.36 45.5 8.79 tp672m-300; tp672m-300b 1000(iec) 300 36.1 ...

  • Page 13

    Model maximum system voltage (v) pmax (w) vmpp (v) impp (a) voc (v) isc (a) fuse rating (a) tp672p-315; 1000(iec) 315 36.6 8.61 45.4 9.17 15 tp672p-310; 1000(iec) 310 36.4 8.52 45.2 9.09 tp672p-305; 1000(iec) 305 36.2 8.43 45.0 8.99 tp672p-300; tp672p-300b 1000(iec) 300 36.0 8.33 44.8 8.90 tp672p-29...

  • Page 14

    Model maximum system voltage (v) pmax (w) vmpp (v) impp (a) voc (v) isc (a) fuse rating (a) tp636p-150; tp636p-150b 1000(iec) 150 18.0 8.33 22.7 8.78 15 tp636p-145; tp636p-145b 1000(iec) 145 17.8 8.15 22.5 8.61 tp636p-140; tp636p-140b 1000(iec) 140 17.7 7.91 22.4 8.43 tp636p-135; tp636p-135b 1000(ie...

  • Page 15

    Headquarter talesun solar co.,ltd. 1# talesun road, shajiabang, changshu, suzhou, jiangsu province, p.R. China 215542 tel.: +86 400 885 1098 fax: +86 512 5290 6773 e-mail: sales@talesun.Com web: www.Talesun.Com european head office talesun solar germany gmbh central tower munich landsberger strasse ...