Tamarack Technologies HV series Product Manual & Installation Manual - page 3
Wiring
Important - W
iring the HV is different than a normal ON/OFF fan. Because the doors are motorized, they need power to
open and power to close. The HV requires a constant source of power. The fan operation is controlled internally.
Please follow the instructions carefully. It is recommended that the wiring of the HV be done by a licensed electrician.
Be sure to turn off power before wiring the HV Whole House Fan
HV1000
HV1600 (Optional Wiring)
Hardwiring the unit to wall switches using the BLUE and
YELLOW wires will provide additional, manual control.
Using these switches will override the remote control
function.
The HV whole house cooling fans are not for use with solid state speed controls
Specifications
Voltage …………………………….
Power
HV1000
…………………..….......
HV1600
…………………..….......
Airflow @ .03” (System)
HV1000 …………..............…….
HV1600 High……………...…….
HV1600 Low ……………………
115VAC 60 Hz
147 Watts
227 Watts
1000 CFM
1600 CFM
900 CFM
R-Value
HV1000 & HV1600-GR
…………
HV1000-DB & HV1600-GDR
…..
Weight
HV1000………………………..….
HV1600……………………………
Rough Opening
……………………
Grille Dimensions
………………….
Grille Color
………………………...
R-22
R-38
17 Lbs.
21 Lbs.
14 ½” x 22 ½”
15 ¾” x 25 ¾”
White
Care
All the motors in the HV are permanently sealed and do not require oiling. To keep dirt, dust and debris from the fans we
recommend that you periodically remove the grille from within the living space and dust the fan blades. Please remember
to make sure that the fan is OFF before dusting the fan blades.