TANDBERG 0100400003AA User Manual - page 15
Document No.
D&TQP0302-11(0)
Revision No.
01
Page
14 of 22
7. User control function
8.1 User Controls
We will not provide remote controller, because no need to control the OSD function normally, but
will provide it for service engineer to check the RS232C function easily.
Following is the description how you can adjust or change the OSD function
Function name
Operation
RS232C command from
external controller
POWER
• Monitor power on and off
@@1KESPWR
MENU
• With OSD deactivated, Activated to OSD menu
• With OSD activated, Exit from main menu or sub menu.
@@1KESMNU
SOURCE
• With OSD deactivated, you can see the kind of displayed
source on right under of the screen.
@@1KESSRC
UP
• With OSD deactivated, Hot key of the brightness control
and increases the brightness.
• With OSD activated, move the cursor upward.
@@1KESUPK
DOWN
• With OSD deactivated, Hot key of the brightness control
and decreases the brightness.
• With OSD activated, move the cursor downward
@@1KESDWN
PLUS
• With OSD deactivated, Hot key of the contrast control
and increases the contrast.
• With OSD activated, enter sub menu and increases the
adjustment of the selected
@@1KESPLS
MINUS
• With OSD deactivated, Hot key of the contrast control
and decreases the contrast.
• With OSD activated, decreases the adjustment of the
selected function.
@@1KESMNS
SET
• With OSD activated, Enter sub menu and change each sub
menu’s item
@@1KESSET
z
3
rd
character “1” of the RS232C command is the unit ID, so this can be changed according to
unit ID.