TANDBERG AudioScience D 50053 Assembly And Installation Instructions Manual

Summary of AudioScience D 50053

  • Page 1

    Assembly and installation instructions for the audioscience microphone tandberg d 50053, rev 5.0

  • Page 2

    Assembly and installation instructions for the audioscience microphone d50053, revision 5.0 page 1 audioscience microphone parts listing before proceeding, please ensure that the following list of parts was received with your new audioscience microphone package. If any part is missing or damaged, co...

  • Page 3: Installation Considerations

    Assembly and installation instructions for the audioscience microphone d50053, revision 5.0 page 2 installation considerations 1. The standard hardware included with the microphone is intended to be clipped to ceiling tracks with the standard inverted “t” shaped cross-section, and with the horizonta...

  • Page 4

    Assembly and installation instructions for the audioscience microphone d50053, revision 5.0 page 3 selecting a mounting location the mounting location of the audioscience microphone can be determined through the application of five principles. These principles are to be used as a general guide as to...

  • Page 5

    Assembly and installation instructions for the audioscience microphone d50053, revision 5.0 page 4 4. The microphone should be mounted far enough away from the videoconferencing system such that one or both boundaries of the microphone are between the microphone element and the loudspeakers of the v...

  • Page 6

    Assembly and installation instructions for the audioscience microphone d50053, revision 5.0 page 5 typical room mounting arrangement 14’(4.3m) maximum m i c 14’(4.3m) maximum m i c m i c typical “boardroom” mounting arrangement 14’ (4.3m) maximum system microphone m i c 10’(3m) minimum.

  • Page 7

    Assembly and installation instructions for the audioscience microphone d50053, revision 5.0 page 6 assembly and installation instructions 1. Read the “installation considerations” on page 2 and proceed after all considerations have been understood and satisfied. 2. Read the guidelines for “selecting...

  • Page 8

    Assembly and installation instructions for the audioscience microphone d50053, revision 5.0 page 7 8. With the assistance of another person, attach the audioscience microphone assembly to the ceiling. This is done by supporting the plastic boundary structure while the cable suspension assemblies are...

  • Page 9

    Assembly and installation instructions for the audioscience microphone d50053, revision 5.0 page 8 13. Replace the ceiling tiles. Small notches may need to be cut in the ceiling tiles to allow for the microphone cable and safety cables. 14. Using the brillianize plastic cleaner, and the sofkloth tow...

  • Page 10: Specifications:

    Assembly and installation instructions for the audioscience microphone d50053, revision 5.0 page 9 specifications: physical: maximum dimensions: 52 inches (132cm) x 27.5 inches (70cm) x 13 inches (33cm) weight: 14 pounds (6.3kg) shipping weight: 24 pounds (10.9kg) ……………………………………………………………………………………. E...

  • Page 11

    Assembly and installation instructions for the audioscience microphone d50053, revision 5.0 page 10 acoustical: frequency response: horizontal polar response:.