Tandem 70 Owner's Manual - page 6
OPERATION AS DC CAMERA SUPPLY FROM MAINS
TheTandem
®
70willautomaticallyoperateasaDCpowersupplyoncethecamera,orotherdeviceisturnedon.Therearenoswitches,itis
fullyautomatic.ThesinglegreenLEDwilllightindicatingthattheunitisoperatingasapowersupply.
AbatterymaybeattachedtoTandem
®
70whilemountedtoacamera.WiththecameraOFF,thebatterywillcharge.Whencameraisturned
ON,Tandem
®
70willsupplypowertocamerarememberingthepointatwhichitleftcharging.Whencameraisturnedoff,Tandem
®
70will
againresumebatterycharging.
IfAClinevoltageisremovedfromtheTandem
®
70,andachargedbatteryismountedontheunit,powerfromthebatterywillberoutedtothe
camera.WhenAClinevoltageisrestored,thebatterywillbere-evaluatedforaproperchargeroutine.
TIP:Whencameraisusedonstakeout,(suchasindoorsonatripod)keepingabatterymountedtotheTandem
®
70allowsinstantswitchingto
handheld.Simplyremovethepowercordforanautomaticswitchtobatterypower.
AtalltimeswhentheTandem
®
70ismountedtothecamera,whetheronACorbattery,thetotalcontinuousloadlimitis70watts@16.4VDC.
WARNING: DO NOT OPERATE THIS UNIT IN THE RAIN.
POWER LOSS
IfACpowerislostduringoperationtheunitwillfunctioninthefollowingmanner:
-Whenpoweringacamerawithabatteryapplied,thegreenstatusLEDwillblinkonceeverythreeseconds.Thebatterywilltakeoverpoweringthe
cameraaslongasthebatteryischarged.
-Whenpoweringacameraandnobatteryisapplied,noLEDswillbelit.
FCC NOTICE
ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassAdigitaldevicepursuanttoPart15oftheFCCRules.These
limitsaredesignedtoprovidereasonableprotectionagainstharmfulinterferencewhentheequipmentisoperatedinacommercialenvironment.
Thisequipmentgenerates,uses,andcanradiateradiofrequencyand,ifnotinstalledandusedinaccordancewiththeinstructionmanual,may
causeharmfulinterferencetoradiocommunications.Operationofthisequipmentinaresidentialareaislikelytocauseharmfulinterferencein
whichcasetheuserwillberequiredtocorrecttheinterferenceathisownexpense.
Thisequipmenthasbeenapprovedbyoneormoreagencies.Allchangesand/ormodificationsnotexpresslyapprovedbyAntonBauer,Inc.
couldvoidtheusers’warrantyandauthoritytooperatethisequipment.Therearenoserviceablepartsinthisequipment.
SPECIFICATIONS
Size
5.2”x4.03”x2.19”
Weight
16oz(1lb.)
InputVoltage
100-240VAC50/60Hz
OutputVoltage
16.4VDC
FuseRating
7ampSurfaceMount
MaximumPower
70wattsat16.4volts
FUSE/TYPE REPLACEMENT
ThefuseoftheTandem
®
70isaPCBmounteddevicewhichshouldonlybereplacedbyaqualifiedservicetechnician.
4