Tanita MC-780MA Instruction Manual

Manual is about: BODY COMPOSITION ANALYZER

Summary of MC-780MA

  • Page 1

    Please read this instruction manual carefully and keep it for future reference. Temperature : 5°c – 35°c relative humidity : 30% – 80% (without condensation) maximum altitude : 2,000m asl pressure : 86kpa - 106kpa temperature : -10°c – 50°c relativehumidity : 10% – 90% (without condensation) body co...

  • Page 2: Efficacy

    2 gb efficacy intended use •this equipment can be used in the screening of certain adult diseases and conditions related to body weight and composition. •the equipment can be used in the monitoring and prevention of conditions caused by excessive deposits of fatty tissue such as diabetes, hyperlipid...

  • Page 3: Contents

    3 gb contents before use how to use troubleshooting 25 specifications 26 if necessary body composition mode 17 measurement results 19 scale mode 21 weight lock mode 22 output and storage of measurement results 23 taking a measurement 17 for your safety 4 part names & connection 8 preparation 10 powe...

  • Page 4: Before Use

    4 gb before use (c au tio ns fo r s afe ty) for your safety prohibited warning caution his mark indicates actions that are prohibited. This mark indicates instructions that must always be followed. Warning do not handle the plug with wet hands. This may result in electric shock, fire, or leakage. Ke...

  • Page 5: Before Use

    5 gb before use (c au tio ns fo r s afe ty) always… keep away from water. Do not jump on the equipment. Avoid using on subjects with metal allergies. Allergic reactions may be caused by the stainless steel used in the electrodes of this device. Do not lean on the equipment. Be sure to use the includ...

  • Page 6: Before Use

    6 gb for accurate measurements before use (c au tio ns fo r s afe ty) avoid measuring after strenuous exercise. Avoid measuring in multiple locations with greatly differing temperatures. This may cause inaccurate measurements. Please take measurements after sufficient rest. Use in a stable location....

  • Page 7: Before Use

    7 gb scheduled maintenance before use (c au tio ns fo r s afe ty) update settings, replace items, or call for service as necessary according to the results of the visual inspections. Do not use the unit if you see any signs of damage. Equipment that has been damaged must be checked for proper operat...

  • Page 8: Before Use

    8 gb before use (c au tio ns fo r s afe ty) * for accurate measurement, place the machine as level as possible. * rotate the adjustable feet in 4 positions for adjustment so that the bubbles of the level gauge reach the centre. Status when the level gauge is viewed from above checking the lev contro...

  • Page 9: Before Use

    9 gb before use (c au tio ns fo r s afe ty) turn on / off the power reset zero point display body fat (percentage and mass) *not measured value but calculated value *not measured value but calculated value *not measured value but calculated value display visceral fat rating display body muscle (perc...

  • Page 10: Before Use

    10 gb platform / control box / accessories preparation setting up the main unit □ instruction manual (this manual) □ assembly guide □ screw (2 items) □ slit cover □ usb b mini cable □ screw driver □ ac cord □ ac adapter c e b e f g h i j k l □ base slit cover □ control unit cover before use (c au ti...

  • Page 11: Before Use

    11 gb gb assembly b 3 4 1 a 2 1 3 2 2 c f before use (c au tio ns fo r s afe ty) 1.

  • Page 12: Before Use

    12 gb preparation setting up the mainunit assembly (continued) 5 6 7 e before use (c au tio ns fo r s afe ty) a d.

  • Page 13: Before Use

    13 gb gb g j + k assembly (continued) 8 9 10 before use (c au tio ns fo r s afe ty).

  • Page 14: Turning The Main Power On.

    14 gb power supply turning the main power on/off turning the main power on. Turning the main power off. Emergency shut down press the key to turn on the power. The initial screen is displayed. Press the key to turn the power off. Before use (c au tio ns fo r s afe ty) keep the area around the plug s...

  • Page 15: Key.

    15 gb gb save changes and return return without saving •the key cannot be used when the scale is measuring weight or impedance. Note note note settings 2 1 select the setting item from the list below. Enter numerical values and press the key. Setting item list setting enter press the key to change t...

  • Page 16: Select

    16 gb settings (continued) select the measurement mode select the measurement mode by pressing the key. The measurement mode is switched in the following order when the key is pressed: "body composition" the " " mark is displayed when the scale mode is selected. Body composition mode mc-780 iii max ...

  • Page 17: How to Use

    17 gb gb taking a measurement how to use (c au tio ns fo r s afe ty) body composition mode enter the preset tare value (clothes weight) turn the power on, and check that the " " mark is displayed. Enter the preset tare value (clothes weight) the tare value range is 0.0 - 10.0kg 1 enter id number if ...

  • Page 18: How to Use

    18 gb taking a measurement (continued) how to use (c au tio ns fo r s afe ty) body composition mode select gender 5 enter height 7 note target body fat p.24 set target body fat ratio if the target body fat ratio function is set to off, the scale switches directly to "measuring impedance" without ent...

  • Page 19: Measurement Results

    19 gb gb measurement results (body composition mode) output measurement results (body composition mode) fat the measurement results are displayed on the lcd after measurement is completed. The results are output to the pc immediately after measurement is completed. Press the key to select the measur...

  • Page 20: Body Water

    20 gb taking a measurement (continued) body water body weight (kg) body water % body water (kg) body water mark basal metabolic rate body weight (kg) bmr (kj) bmr (kcal) bmr mark bmi body weight (kg) bmi bmi mark visceral fat rating vfr mark body weight (kg) visceral fat rating measurement results (...

  • Page 21: Scale

    21 2 1 gb gb scale mode enter the id number if the id number function is set to off, the scale starts measuring your weight immediately. Enter the id number. The id number range is from 0 to 9999999999999999. Press to enter tare value (clothes weight). The tare value range is 0.0 - 10.0kg. Wait unti...

  • Page 22: Weight Lock Mode

    22 gb taking a measurement (continued) weight lock mode the " " is displayed after the scale mode is selected. Enter the preset tare value (clothes weight) the tare value range is 0.0 - 10.0kg. The " " mark and " " are displayed when the weight lock mode is selected. Measure body weight enter the pr...

  • Page 23: Data Output

    23 gb gb data output output and storage of measurement results outputting measurement results via the usb port the results are output to the pc immediately after measurement is completed. Data is output in csv format. Data storage data storage of measurement results the results are saved to the sd c...

  • Page 24: How to Use

    24 gb how to use (c au tio ns fo rs afe ty) output and storage of measurement results (continued) reading stored measurement result data the selected file is displayed on the right side of the lcd. The file name is displayed as shown below: top of the lcd: "yyyy". Centre of the lcd: "mm dd". Select ...

  • Page 25: If Necessary

    25 gb gb troubleshooting if necessary (c au tio ns fo r s afe ty) problem solution please check the following before requesting repair. “------” is displayed. Error with zeroing the weight value does not stabilize. Measurement display error with impedance measurement •hold the handgrips and electrod...

  • Page 26: If Necessary

    26 gb specifications model number accuracy grade impedance measurement weight measurement usage conditions power source electric current range measurement system measurement frequency measurement current electrode materials measurement part measurement range accuracy at first calibration measurement...

  • Page 27: If Necessary

    27 gb id gender body type age height clothes weight 16 digits female/male standard/athletic * 1 5 - 99 years 90.0 - 249.9cm (0.1cm increments) 0kg - 10.0kg (0.1kg increments) 0kg - 270.0kg (0.1kg increments) 1.0% - 75.0% (0.1% increments) (0.1kg increments) (0.1kg increments) (0.1kg increments) (0.1...

  • Page 28

    This product meets the following requirements ; 1. Non-automatic weighing instruments (2009/23/ec) 2. Medical device directive (93/42/eec) 3. Rohs directive (2011/65/eu) copyright © 2013 tanita corporation. All rights reserved. Jan.2013.Hk.F.Mc7807601(0) disposal this equipment is an electronic devi...