7.0: TECHNICAL SPECIFICATIONS
(1) +/- 3 dB, measured at 1m in an anechoic chamber. (2) Peak SPL at mix position for 1 pair driven.
Tannoy operates a policy of continuous research and development. The introduction of new materials or manufacturing methods will always equal or exceed the published specifications which Tannoy reserve the right to alter without
prior notice. Please verify the latest specifications when dealing with critical applications.
NOTES
Input
Sensitivity
Crossover frequency
Amplifier output power
User Controls
Power supply
ELECTRONIC SECTION
600Ω balanced on combined XLR/jack
0.775 Vrms (0 dBu)
2.7kHz
LF 40 W rms HF HF 20 W rms
Front panel mounted on/standby/mute LED indicator, gain control
Fixed mains voltage
IEC inlet with detachable power cord
Region Specific (to order)
Frequency response (1)
Maximum SPL (2)
Distortion
Drive unit LF/MID
WideBand™ HF
Shielded
SYSTEM
70Hz – 30 kHz
109dB
<0.7%
130mm (5") multi fibre paper pulp cone
25mm (1") soft neodymium magnet system
Yes
Low frequency design
Cabinet construction
Cabinet finish
Cabinet dimensions (HxWxD)
Total Cabinet weight
CABINET
Optimised bass-reflex loaded
MDF cabinet and front baffle, tongue and groove front and back
Grey cabinet with blue painted baffle
298.8 mm (11
3
/
4
”) x 184mm (7
1
/
4
”) x 304.3 mm (12”)
7.8kg (17.15lbs)
8.0: SERVICING 8.1: CABINET FINISH
To remove marks and scuffs use a soft brush. If necessary, a little warm water and detergent can be used but under no circumstances use a solvent or
abrasive cleaner.
8.2: DRIVER REMOVAL
Lay the cabinet on its back. Remove the ten hexagonal screws and set aside. Ease the driver from the front of the cabinet taking care not to mark the
front surface. Remove the driver, note the polarity of the internal connections and disconnect the internal wiring. Take care not to damage the moving
parts of the LF driver. To refit the driver, connect the cables from the crossover to the LF terminals. Fit the driver into the mounting hole, making sure
that the internal connecting cables are not trapped or able to touch the LF cone. Fasten the screws finger tight and then progressively tighten them down
with the appropriate Allen key. Repeat the same procedure for the HF driver.
8.3: AMPLIFIER
A fuse is located just under the mains input (fig 1). Replacement is simple and a spare fuse is provided inside the fuse housing itself. Always use the
correctly rated fuse, as indicated on the silk screen-printing. Only qualified and authorised personnel should undertake any other servicing regarding
the amplifier section.
In case of any malfunction of the unit, the first thing to check should be the input connection, more especially if the source has unbalanced outputs (see
"Connecting your speakers" section) as improper connection can result in significant level reduction and affect the response.
8.4: LIST OF SPARE PARTS
PART NUMBER
DESCRIPTION
Driver kit - Type 1218
High Frequency Unit – Type 0293
Amplifier- complete unit 100v – 120v
Amplifier- complete unit 220v – 240v
Amplifier Board Assembly
Features Board Assembly
Transformer
9.0: WARRANTY
NO MAINTENANCE OF THE REVEAL 5A MONITOR IS NECESSARY.
All components are guaranteed for a period of one year from the date of manufacture, subject to the absence of, or evidence of, misuse, overload
or accidental damage.
For further information please contact your dealer or the distributor in your country.
If you cannot locate your distributor please contact:
Customer Services, Tannoy Ltd., Coatbridge, Strathclyde, ML5 4TF, Scotland
Telephone: 01236 420199 (UK) +44 1236 420199 (International)
Fax: 01236 428230 (UK) +44 1236 428230 (International)
Internet: http://www.tannoy.com
DO NOT SHIP ANY PRODUCT TO TANNOY WITHOUT PREVIOUS AUTHORISATION
This warranty in no way affects your statutory rights.
10.0: DECLARATION OF CONFORMITY
The following apparatus is/are manufactured in China by Tannoy Ltd of Rosehall Industrial Estate, Coatbridge, Scotland, ML5 4TF. The following
equipment is marked with the CE label and conform(s) to the protection requirements of the European Electromagnetic Compatibility Standards
and Directives. The apparatus is designed and constructed such that electromagnetic disturbances generated do not exceed levels allowing radio
and telecommunications equipment and other apparatus to operate as intended, and, the apparatus has an adequate level of intrinsic immunity
to electromagnetic disturbance to enable operation as specified and intended.
Details of the Apparatus: Reveal 5A Studio Monitor
The equipment listed above is covered by this certificate and marked with the CE-label conforms to the following standards:
EN 60065
Safety requirements for mains operated electronic and related
(IEC 60065)
apparatus for household and similar general use
EN 55103-1
Product family standard for audio, video, audio-visual and entertainment lighting control apparatus for professional
use. Part 1: Emission.
EN 55103-2
Product family standard for audio, video, audio-visual and entertainment lighting control apparatus for professional
use. Part 2: Immunity.
With reference to regulations in following directives: 73/23/EEC, 89/336/EEC
Signed:
Position: Technical
Director
Date:
1 March 2005
For Tannoy Ltd
7900 0746
7900 0762
7300 1039
7300 0938
7600 1589
7600 1571
3212 0135