Tansun Quartzheat Apollo A1A 010 Reference Manual - page 2
I n t r o d u c t i o n
Tansun’s range of linear quartz heaters are carefully designed to blend into environments old and new, providing a cost effective,
pollution free heater.
Please read the following instructions carefully before use. The safety of this heater is guaranteed only by its correct usage in
accordance with these instructions, therefore it is recommended that they are retained for future reference.
C a u t i o n
•
Before using this appliance:
- Check that the voltage indicated on the type plate corresponds to the mains supply voltage.
- Ensure that the heater has been securely fixed to the mounting bracket on the wall.
•
Disconnect from the supply by removing the plug from the mains socket (or disconnect pole switch) during installation, cleaning and/
or lamp replacement and always ensure that the lamp is cool.
•
The heater must not be located immediately below a socket outlet.
•
Do not handle the halogen lamp with bare hands. If it is inadvertently touched, remove finger marks with a soft cloth and methylated
spirit or rubbing alcohol, otherwise the marks will burn into the quartz glass, causing premature heater failure.
•
Do not use an extension cord with this product.
•
Keep the mains cord away from the body of the heater which will get hot during use.
•
Do not cover or obstruct the heater when in use.
•
Ensure that children do not tamper with the heater.
•
Do not insert any object through any slot or opening in the heater.
•
Do not install less than the minimum mounting distance from the floor.
•
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack
of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person
responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
•
WARNING: This heater is not equipped with a device to control the room temperature. Do not use this heater in small rooms when
they are occupied by persons not capable of leaving the room on their own, unless constant supervision is provided.
•
This heater is for indoor use only - do not install outdoors or use the heater in a damp area, for example a bathroom or near to a
swimming pool.
•
WARNING: This appliance must be connected to a supply that is earthed!
R i s k o f F i r e
Keep combustible materials such as furniture, papers, clothes and curtains at least 1.8m (6 feet) from the front of the heater and away
from the sides and rear.
For industrial installations, the units must be supplied via double pole miniature
circuit breakers (MCB) with instantaneous coefficients in the range 7 to 10 with a
separation of at least 3mm between contacts. Refer to Table 1 for MCB ratings.
1. Remove cover from terminal box mounted at the rear of the heater.
2. Select which knock-out hole is to be used in the terminal box and remove the
blanking piece and fit the strain relief bush.
3. Select a suitable heat resistant supply cord (see Table 1 for ratings) and feed
the through strain relief bush and connect to the terminal block and earth stud
(as shown in Fig. 1).
4. Fully tighten the cord grip on the strain relief bush.
5. Replace the terminal box cover.
S p e c i f i c a t i o n
Table 1 UK AND EUROPEAN HEATERS
Model
Voltage
Lamps
Total
Phase
Amps
Minimum
Minimum
Minimum
Dimensions
Weight
(without
(V)
x
power
supply
per
height from
distance
distance
(L x W x D)
without
guard)
power (kW)
(kW)
(V)
phase (A)
floor
from ceiling
from side wall
(mm)
guard
A1A 010
230
1 x 1.0
1.0
1
4.3
2.1m
0.3m
1.5m
420 x 225 x 115
4.0kg
A1A 015
230
1 x 1.5
1.5
1
6.5
2.1m
0.3m
1.5m
420 x 225 x 115
4.0kg
A1A 020
230
1 x 2.0
2.0
1
8.7
2.5m
0.5m
1.5m
420 x 225 x 115
4.0kg
A1B 020
230
2 x 1.0
2.0
1
8.7
2.5m
0.5m
1.5m
420 x 390 x 115
5.0kg
A1B 030
230
2 x 1.5
3.0
1
13.0
3.0m
0.5m
1.5m
420 x 390 x 115
5.0kg
A1B 040
230
2 x 2.0
4.0
1
17.4
3.5m
0.5m
1.5m
420 x 390 x 115
5.0kg
A1C 030
230
3 x 1.0
3.0
1
13.0
3.0m
0.5m
1.5m
420 x 525 x 115
6.5kg
A1C 045
230
3 x 1.5
4.5
1
19.6
3.5m
0.5m
1.5m
420 x 525 x 115
6.5kg
A1C 060
230
3 x 2.0
6.0
1
26.0
4.5m
0.5m
1.5m
420 x 525 x 115
6.5kg
A1J 020
230
2 x 1.0
2.0
1
8.7
2.5m
0.5m
1.5m
855 x 255 x 115
7.0kg
A1J 030
230
2 x 1.5
3.0
1
13.0
3.0m
0.5m
1.5m
855 x 255 x 115
7.0kg
A1J 040
230
2 x 2.0
4.0
1
17.4
3.5m
0.5m
1.5m
855 x 255 x 115
7.0kg
A1K 030
230
3 x 1.0
3.0
1
13.0
3.0m
0.5m
1.5m
1280 x 225 x 115
10.0kg
A1K 045
230
3 x 1.5
4.5
1
19.6
3.5m
0.5m
1.5m
1280 x 225 x 115
10.0kg
A1K 060
230
3 x 2.0
6.0
1
26.0
4.5m
0.5m
1.5m
1280 x 225 x 115
10.0kg
A3C 030
400
3 x 1.0
3.0
3*
4.3
3.0m
0.5m
1.5m
420 x 525 x 115
6.5kg
A3C 045
400
3 x 1.5
4.5
3*
6.5
3.5m
0.5m
1.5m
420 x 525 x 115
6.5kg
A3C 060
400
3 x 2.0
6.0
3*
8.7
4.5m
0.5m
1.5m
420 x 525 x 115
6.5kg
A3E 060
400
6 x 1.0
6.0
3*
8.7
4.5m
0.5m
1.5m
855 x 632 x 115
13.5kg
A3E 090
400
6 x 1.5
9.0
3*
13.0
5.0m
0.5m
1.5m
855 x 632 x 115
13.5kg
A3E 120
400
6 x 2.0
12.0
3*
17.4
5.0m
0.5m
1.5m
855 x 632 x 115
13.5kg
A3K 030
400
3 x 1.0
3.0
3*
4.3
3.0m
0.5m
1.5m
1280 x 255 x 115
10.0kg
A3K 045
400
3 x 1.5
4.5
3*
6.5
3.5m
0.5m
1.5m
1280 x 255 x 115
10.0kg
A3K 060
400
3 x 2.0
6.0
3*
8.7
4.5m
0.5m
1.5m
1280 x 255 x 115
10.0kg
* Star connection with neutral star point to balance load.
Use MCB Type 3.
I n s t a l l a t i o n
The models A1A 010, A1A 015, A1A 020, A1B 020, A1B 030 and A1C 030 are fitted with 2.0 meters of supply cord for hard wiring
therefore it is unnecessary to remove the terminal cover plate in order to carry out normal installation of these models. They can also
be specified with 5.0 meters of supply cord and a molded UK or Euro plug (at an additional cost). Again it is unnecessary to remove the
terminal cover plate in order to carry out normal installation of these models.
The models A1B 040, A1C 045 and A1C 060 are fitted with 2.0 meters of supply cord for hard wiring therefore it is unnecessary to
remove the terminal cover plate in order to carry out normal installation of these models. All other models have a terminal box in which
the mains supply cord can be connected.
•
Warning - this appliance must be earthed!
•
Please observe the minimum safe distance between the heater body and any inflammable surfaces.
•
All installations must be in accordance with I.E.E. safety regulations. If in any doubt, please consult a suitably qualified electrician.
•
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to
avoid a hazard.
Fig. 1