Tascam CD-01 U Specifications - page 18
TASCAM CD-01U/CD-01U PRO RS-232C Protocol Specifications
18
TEAC Corporation
5. Return Command Detail
5-1. TIME DATA
When the Time mode is set to other than “OFF” with TIME DATA SEND SELECT command [3F],
controlled device outputs the time data in specified form by TIME DATA SEND SELECT command [3F].
Command
88
Data
8 bytes
Description
Remarks
Data 1
Tens digit of minutes
Data 2
Units digit of minutes
Data 3
Thousands digit of minutes
Data 4
Hundreds digit of minutes
Data 5
Tens digit of seconds
Data 6
Units digit of seconds
Data 7
Tens digit of frames
Data 8
Units digit of frames
5-2. INFORMATION RETURN
Transmitted in response to an INFORMATION REQUEST command [0F].
Returns the software version of the controlled device.
Command
8F
Data
4 bytes
Request command INFORMATION REQUEST [0F]
Data 1
Tens digit of software version
Sample data for Data 1 - Data 4
Data 2
Units digit of software version
0100
Version 1.00
Data 3
1
st
decimal digit of software version
Data 4
Hundreds digit of software version
5-3. AUTO CUE LEVEL RETURN
Transmitted in response to an AUTO CUE LEVEL PRESET command [20] with the request data ([FF])
to show the currently set Auto Cue level.
Command
A0
Data
2 bytes
Request command AUTO CUE LEVEL PRESET [20]
Data 1
Data 2
Description
Remarks
0
0
-24dB
Auto Cue detect level is set to –24dB
0
1
-30dB
Auto Cue detect level is set to –30dB
0
2
-36dB
Auto Cue detect level is set to –36dB
0
3
-42dB
Auto Cue detect level is set to –42dB
0
4
-48dB
Auto Cue detect level is set to –48dB
0
5
-54dB
Auto Cue detect level is set to –54dB
0
6
-60dB
Auto Cue detect level is set to –60dB
0
7
-66dB
Auto Cue detect level is set to –66dB
0
8
-72dB
Auto Cue detect level is set to –72dB