Task Force Tips CROSSFIRE Operation And Maintenance Instructions

Summary of CROSSFIRE

  • Page 1

    ©copyright task force tips, inc. 2002-2018 lix-030 january 8, 2018 rev24 manual: crossfire ® monitor instructions for safe operation and maintenance danger understand manual before use. Operation of this device without understanding the manual and receiving proper training is a misuse of this equipm...

  • Page 2: Danger

    ©copyright task force tips, inc. 2002-2018 lix-030 january 8, 2018 rev24 2 danger personal responsibility code the member companies of femsa that provide emergency response equipment and services want responders to know and understand the following: 1. Firefi ghting and emergency response are inheren...

  • Page 3: Danger

    ©copyright task force tips, inc. 2002-2018 lix-030 january 8, 2018 rev24 3 1.0 meaning of safety signal words a safety related message is identifi ed by a safety alert symbol and a signal word to indicate the level of risk involved with a particular hazard. Per ansi standard z535.6-2011, the defi niti...

  • Page 4: Caution

    ©copyright task force tips, inc. 2002-2018 lix-030 january 8, 2018 rev24 4 2.0 safety caution monitor must be properly connected to a hose and nozzle with matched threads. Mismatched or damaged threads may cause leaking or uncoupling under pressure and could cause injury. Caution dissimilar metals c...

  • Page 5

    ©copyright task force tips, inc. 2002-2018 lix-030 january 8, 2018 rev24 5 3.2 specifications 3.2.1 mechanical crossfire monitor safe-tak 1250 base weight 17 lbs 24 lbs storage volume 4060 in 3 1620 in 3 l-w-h 20 x 14-1/2 x 14 20 x 9 x 9 height above truck flange 12-1/2 in na height above truck deck...

  • Page 6: Warning

    ©copyright task force tips, inc. 2002-2018 lix-030 january 8, 2018 rev24 6 4.4 side-to-side rotation and rotation lock side-to-side rotation is accomplished by rotating the monitor on its base. The rotational position can be locked by moving the rotation lock lever to its down position as shown in f...

  • Page 7

    ©copyright task force tips, inc. 2002-2018 lix-030 january 8, 2018 rev24 7 4.7 truck mount base the crossfire monitor may be used from a truck by using a truck mount adapter. The truck mount adapter can be bolted to a three inch riser pipe with a three inch 150 lb. Asa companion fl ange and gasket us...

  • Page 8

    ©copyright task force tips, inc. 2002-2018 lix-030 january 8, 2018 rev24 8 4.10.4 pressure loss 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 loss (bar) flow (l/min) crossfire top with safe-tak 1250 base crossfire top 0 200 400 600 800 1000 1200 flow ...

  • Page 9: Warning

    ©copyright task force tips, inc. 2002-2018 lix-030 january 8, 2018 rev24 9 5.0 safe-tak 1250 base the portable base allows the monitor to be positioned in places that are not accessible with a fi re truck. As an added measure of safety, the safe-tak 1250 portable base has a safety valve. The function...

  • Page 10: Warning

    ©copyright task force tips, inc. 2002-2018 lix-030 january 8, 2018 rev24 10 5.5 portable base anchoring the safest method of restraining the monitor is to use a tie down strap. It is inherently more reliable than other methods since it does not rely on traction or digging in of the spikes. It is als...

  • Page 11

    ©copyright task force tips, inc. 2002-2018 lix-030 january 8, 2018 rev24 11 disconne cting, o verriding, or tampering w ith this safety dev ice may re sult in pe rsonal injury. 1) manually reduce or remove the flow of water to the monitor. 2) correct cause of tripped valve. 3) rotate lever in direct...

  • Page 12: Warning

    ©copyright task force tips, inc. 2002-2018 lix-030 january 8, 2018 rev24 12 6.1 storage bracket tools required: electric drill drill bits see instructions for correct size #3 phillips screw driver 7/16 or adjustable wrench 5/32 allen wrench the crossfire portable monitor storage bracket comes with 1...

  • Page 13

    ©copyright task force tips, inc. 2002-2018 lix-030 january 8, 2018 rev24 13 8.0 drawings & parts list 8.1 monitor drawing and part list ©copyright task force tips, inc. 2002-2015 lix-030 may 22, 2015 rev23 manual: crossfire monitor with safe-tak 1250 base instructions for safe operation and maintena...

  • Page 14: Safe-Tak 1250®

    ©copyright task force tips, inc. 2002-2018 lix-030 january 8, 2018 rev24 14 8.2 safe-tak 1250 drawing and part list safe-tak 1250® with safety valve index description qty item # 1 safety valve handle label 1 xl070 2 valve handle 1 x540 3 1/4 x 1 3/8 spirol pin 1 vp250x1.375h 4 torsion spring 1 x560 ...

  • Page 15

    ©copyright task force tips, inc. 2002-2018 lix-030 january 8, 2018 rev24 15 8.3 high flow inlet option 19 20 21 22 23 25 27 24 31 26 17 16 18 15 14 40 39 24 23 24 23 33 35 36 37 38 32 18 9 20 21 22 23 25 27 24 31 26 17 18 40 39 24 23 24 23 33 35 36 37 38 32 16 15 14 18 index description qty item # 1...

  • Page 16

    ©copyright task force tips, inc. 2002-2018 lix-030 january 8, 2018 rev24 16 8.5 double inlet option index description qty item # 1 1/4-28 x 1/2 socket set 2 vt25-28ss500 2 3/16 ss ball 96 v2120 3 safety valve base label 1 xl080 no valve base label xl085 4 2.5" wye 1 x712 5 2.5" clapper 1 x772 6 2.5"...

  • Page 17

    ©copyright task force tips, inc. 2002-2018 lix-030 january 8, 2018 rev24 17 9.0 warranty task force tips, llc., 3701 innovation way, valparaiso, indiana 46383-9327 usa (“tft”) warrants to the original purchaser of its nozzles and other equipment (“equipment”), and to anyone to whom it is transferred...

  • Page 18: Caution

    ©copyright task force tips, inc. 2002-2018 lix-030 january 8, 2018 rev24 18 10.0 maintenance the crossfire portable monitor and its base require little maintenance. The unit should be kept clean and free of dirt by rinsing with water after each use. Any inoperable or damage parts should be repaired ...

  • Page 19

    ©copyright task force tips, inc. 2002-2018 lix-030 january 8, 2018 rev24 19 10.2.2 relief valve test 1. Hydrostatic testing of the appliance shall be conducted prior to testing the relief valve. 2. The relief valve shall be tested separately from any device it is connected to. 3. The relief valve sh...

  • Page 20: Warning

    ©copyright task force tips, inc. 2002-2018 lix-030 january 8, 2018 rev24 task force tips, llc. Made in usa • www.Tft.Com 3701 innovation way, valparaiso, in 46383-9327 usa 800-348-2686 • 219-462-6161 • fax 219-464-7155 10.0 operation checklist before being placed back in service, appliances must be ...