Tau ARM200 Use And Maintenance Manual - Arm225I
13
ARM200 Series
DESCRIPTION
The
ARM200 automated system for swing gates is an electro-me-
chanical non-reversing actuator that transmits motion to the leaf
via a worm screw system.
The actuator is available in more versions in 18V DC and 230V AC.
The non-reversing system ensures the leaf is mechanically locked
when the motor is not operating, but it is not intended as a high
degree security deterrent against intrusion attempts and/or tam-
pering
. A convenient and safe release system with customised key
makes it possible to manually move the leaf in the event of a mal-
function or of a power failure.
ATTENTION:
The correct operation and the declared speciica-
tions only apply if TAU accessories and safety de-
vices are used.
In the absence of a mechanical clutch, the use of
a control unit with an adjustable electronic clutch,
or the installation of a sensitive edge, is required in
order to ensure crush-proof safety.
The ARM200 automated system was designed and
built for controlling vehicle access. It is not intend-
ed as a high degree security deterrent against in-
trusion attempts and/or tampering. Avoid any other
use whatever.
ACTUATOR PARTS (ig.1)
Pos. Description
1
Actuator
2
Release device
3
Rod
4
Wing connection bracket
5
Rear bracket
6
Terminal board cover
DIMENSIONS (ig.2)
INSTALLATION (ig.3)
Electrical set-up (standard system - ARM200)
Pos. Description
Cables
1 Attuatore
4x1,5 mm²
2 Control unit
3x1,5 mm²
(power supply)
3 TX photocells
4x0,5 mm²
4 RX photocells
2x0,5 mm²
5 Key-operated selector switch
3x0,5 mm²
6 Flashing light and aerial
2x1 mm² + 1RG58
7 Mechanical stops
-
Electrical set-up (standard system - ARM200BENC)
Pos. Description
Cables
1 Attuatore
2x2,5 mm² + 3x0,5 mm²
2 Control unit
3x1,5 mm²
(power supply)
3 TX photocells
4x0,5 mm²
4 RX photocells
2x0,5 mm²
5 Key-operated selector switch
3x0,5 mm²
6 Flashing light and aerial
2x1 mm² + 1RG58
7 Mechanical stops
-
Notes:
• Use suitable tubes and/or hoses to lay electric cables
• Choose short routes for cables and keep power cables sepa-
rate from control cables.
Preliminary checks
Prior to installing the automation, make all structural modiications
in order to ensure safety distances and protect and segregate ar-
eas in which people may be exposed to the risk of crushing, shear-
ing, dragging or similar dangers.
• Make sure the existing structure is suficiently sturdy and sta-
ble;
• the mechanical parts must conform to the provisions of Stand-
ards EN 12604 and EN 12605;
• leaf length in compliance with the actuator speciications;
• regular and uniform movement of the leaves, without any fric-
tion and dragging during their entire travel;
• stiff hinges in good conditions;
• presence of both opening and closing mechanical limit stops;
• presence of an eficient earthing for electrical connection of the
actuator.
Perform any necessary metalwork job before installing the auto-
mated system.
The condition of the gate structure directly affects the reliabil-
ity and safety of the automated system.
Installation dimensions (ig.4)
Determine the itting position of the actuator with reference to ig.4.
Check with care if the distance between the open leaf and any ob-
stacles (walls, fences etc.) is higher than the actuator dimensions.
ARM225I
X°
A (mm)
B (mm)
C (mm)
90
110
120 ÷ 165
20 mm
90
115
120 ÷ 160
20 mm
90
120 ÷ 125
120 ÷ 155
20 mm
90
130
120 ÷ 150
20 mm
90
135
120 ÷ 145
20 mm
90
140
120 ÷ 140
20 mm
90
145
120 ÷ 135
20 mm
90
150 ÷ 155
120 ÷ 130
20 mm
90
160
120 ÷ 125
20 mm
90
165
120 ÷ 120
20 mm
100
130
120 ÷ 130
20 mm
100
135
120 ÷ 120
20 mm
ARM250I
X°
A (mm)
B (mm)
C (mm)
90
120 ÷ 125
135 ÷ 275
20 mm
90
130
135 ÷ 270
20 mm
90
135
135 ÷ 265
20 mm
90
140
135 ÷ 260
20 mm
90
145 ÷ 150
135 ÷ 255
20 mm
90
155
135 ÷ 250
20 mm
90
160
135 ÷ 245
20 mm
90
165
135 ÷ 240
20 mm
90
170 ÷ 175
135 ÷ 235
20 mm
90
180
135 ÷ 230
20 mm
90
185
135 ÷ 225
20 mm
90
190 ÷ 195
135 ÷ 220
20 mm
90
200
135 ÷ 215
20 mm
100
145
135 ÷ 160
20 mm
100
150
135 ÷ 210
20 mm
100
155
135 ÷ 225
20 mm
100
160
135 ÷ 220
20 mm
100
165
135 ÷ 215
20 mm
100
170
135 ÷ 210
20 mm
100
170
135 ÷ 205
20 mm
100
180
135 ÷ 200
20 mm
100
185
135 ÷ 195
20 mm
100
190
135 ÷ 190
20 mm
100
195
135 ÷ 185
20 mm
100
200
135 ÷ 180
20 mm
110
170
135 ÷ 140
20 mm
110
175
135 ÷ 155
20 mm
110
180 ÷ 185
135 ÷ 175
20 mm
110
190
135 ÷ 165
20 mm
110
195
135 ÷ 160
20 mm
110
200
135 ÷ 155
20 mm
ENGLISH