Vibration level
The vibration emission level stated in this instruction manual has been measured in
accordance with a standardised test given in EN 61029; it may be used to compare one tool
with another and as a preliminary assessment of exposure to vibration when using the tool for
the applications mentioned
- using the tool for different applications, or with different or poorly maintainted accessories,
may significantly increase the exposure level
- the times when the tool is switched off or when it is running but not actually doing the job,
may significantly reduce the exposure level
Protect yourself against the effects of vibration by maintaining the tool and its
accessories, keeping your hands warm, and organizing your work patterns
ASSemBly
The grinder must be firmly bolted to a workbench. The length of the fixing bolts will depend on
the thickness of the workbench. If the workbench is made of steel, it is advisable to use a
wooden block or plank between the grinder and the bench, to insulate it and prevent vibration.
Assembly and adjustment of eye shield bracket and eye shield
Fig. C (page 12)
The eye shield bracket and eye shield should only ever be assembled/adjusted with the
grinding wheel stationary, and the machine disconnected from the power supply.
Fix the eye shield bracket (4) with attached eye shield to the grinding wheel cover, using
•
the screw provided (A).
Set the eye shield bracket at the correct height. The clearance (B) between the wheel and the
•
eye shield bracket should be 1 to 1.5 mm.
Next tighten the screw (A) firmly.
•
Position the eye shield to give maximum protection when working.
•
Always wear safety glasses.
•
fitting and adjusting tool rest
The tool rest should only be adjusted when the grinding wheel is completely stationary,
and the machine is disconnected from the power supply (the wall socket).