Taylor c713 Operating Instructions Manual - page 10
6
Model C723
Safety
130225
S
DO NOT allow untrained personnel to
operate this machine.
S
DO NOT operate the freezer unless all
service panels and access doors are
restrained with screws.
S
DO NOT remove any internal operating
parts (examples: freezer door, beater,
scraper blades, etc.) unless all control
switches are in the OFF position.
Failure to follow these instructions may result in
severe personal injury to fingers or hands from
hazardous moving parts.
This unit has many sharp edges that can
cause severe injuries.
S
DO NOT put objects or fingers in the door
spout. This may contaminate the product
and cause severe personal injury from blade
contact.
S
USE EXTREME CAUTION when removing
the beater asssembly. The scraper blades
are very sharp.
S
CAUTION-SHARP EDGES: Two people are
required to handle the cup/cone dispenser.
Protective gloves must be worn and the
mounting holes must NOT be used to lift or
hold the dispenser. Failure to follow this
instruction can result in personal injury to
fingers or equipment damage.
Access to the service area of the unit is
restricted to persons having knowledge and practical
experience with the appliance, in particular as far as
safety and hygiene are concerned.
This machine must be placed on a level
surface. Extreme care should be taken in moving it
for any reason. Two or more persons are required to
safely move this machine. Failure to comply may
result in personal injury or equipment damage.
Cleaning and sanitizing schedules are
governed by your state or local regulatory agencies
and must be followed accordingly. Please refer to
the cleaning section of this manual for the proper
procedure to clean this unit.
DO NOT obstruct air intake and discharge openings:
The Model C723 air cooled unit requires a minimum
of 6” (152 mm) on the left and right sides and 0” on
the back. The Model C723 unit equipped with top air
discharge requires 6” (152 mm) on the left side, 0”
on the right side, and 0” on the back.
This will allow for adequate air flow across the
condenser. Failure to allow adequate clearance can
reduce the refrigeration capacity of the freezer and
possibly cause permanent damage to the
compressor.
For Indoor Use Only: This unit is designed to
operate indoors, under normal ambient
temperatures of 70° - 75°F (21° - 24°C). The freezer
has successfully performed in high ambient
temperatures of 104°(40°C) at reduced capacities.
DO NOT run the machine without product. Failure to
follow this instruction can result in damage to the
machine.
NOISE LEVEL: Airborne noise emission does not
exceed 78 dB(A) when measured at a distance of
1.0 meter from the surface of the machine and at a
height of 1.6 meters from the floor.