TCS ER150 Product Manual

Manual is about: Fresh Air Ventilation Systems

Summary of ER150

  • Page 1

    Product data 68-0269 ® u.S. Registered trademark copyright © 2002 • all rights reserved hr150, 200; er150, 200 fresh air ventilation systems application the hr150 and hr200 fresh air ventilation systems provide proper levels of ventilation with energy savings by transferring heat between the exhaust...

  • Page 2: Ordering Information

    Hr150, 200; er150, 200 fresh air ventilation systems 68-0269 2 ordering information when purchasing replacement and modernization products from your total comfort system wholesaler or distributor, refer to the total comfort system catalog or price sheets for complete ordering number. If you have add...

  • Page 3

    Hr150, 200; er150, 200 fresh air ventilation systems 3 68-0269 fig. 1. Ventilation performance. 0 net supply net exhaust 0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 50 150 100 200 250 300 350 400 m6561a cfm (l/s = n x 0.4719) in. Wg (pa = n x 248.8) 25 50 75 100 125 .1 .2 .3 .4 .5 91 89 84 78 69 193 188 1...

  • Page 4: Planning The Installation

    Hr150, 200; er150, 200 fresh air ventilation systems 68-0269 4 fig. 2. Hr150/er150 and hr200/er200 dimensions in in. (mm). Planning the installation application the fresh air ventilation system is designed to supply fresh air and exhaust stale air. The system draws fresh outdoor air through the vent...

  • Page 5

    Hr150, 200; er150, 200 fresh air ventilation systems 5 68-0269 sizing there are several methods that can provide satisfactory results for sizing a ventilator to provide adequate ventilation for a home. The ashrae standard 62-1989 ventilation for acceptable indoor air quality suggests the following: ...

  • Page 6

    Hr150, 200; er150, 200 fresh air ventilation systems 68-0269 6 note: when the home is occupied, continuous operation of the ventilator is recommended. When the furnace air handler operates, fresh air is distributed through the heating/air conditioning supply registers. When the air handler is off, f...

  • Page 7

    Hr150, 200; er150, 200 fresh air ventilation systems 7 68-0269 fig. 7. Independent ventilator installation. Adjustable fresh air supply adjustable dampers for balancing air flow into and out of the house fresh air supply hood stale air exhaust hood flexible insulated ducting with a vapor barrier ven...

  • Page 8: Installation

    Hr150, 200; er150, 200 fresh air ventilation systems 68-0269 8 balancing airflow balancing the airflow verifies that the fresh air ventilation system is delivering the intended airflow and energy performance. Use the airflow balancing instructions in the installation section to check and balance the...

  • Page 9: Wiring

    Hr150, 200; er150, 200 fresh air ventilation systems 9 68-0269 fig. 8. Installing drain line. Construct a p-trap using the plastic t-fitting provided. 1. Cut two lengths of 1/2 in. Id hose and connect each drain fitting to the end of the t-fitting. 2. Position the center leg of the t-fitting so it p...

  • Page 10

    Hr150, 200; er150, 200 fresh air ventilation systems 68-0269 10 fig. 10. Internal schematic for fresh air ventilation systems with manual control and circuit board. T7 209663 24v transformer hs remote dfr2 dfr3 p1 p4 p2 t8 t1 st2 st3 st1 t9 t10 t11 t4 t5 t6 ground neutral line fan o/p thermistor see...

  • Page 11: Startup and Checkout

    Hr150, 200; er150, 200 fresh air ventilation systems 11 68-0269 airflow balancing volume-balanced airflow in the ventilator is required. Volume of outside air brought in must equal volume of air the unit exhausts. If airflow is not correctly balanced: • unit does not operate at its maximum efficienc...

  • Page 12

    Hr150, 200; er150, 200 fresh air ventilation systems 68-0269 12 inspecting exterior hoods inspect exterior hoods at least monthly. Be sure exhaust and fresh air supply hoods are not blocked or restricted by leaves, grass or snow. In winter, be sure snow does not block hoods and frost does not accumu...

  • Page 13: Troubleshooting

    Hr150, 200; er150, 200 fresh air ventilation systems 13 68-0269 troubleshooting see table 1. Table 1. Troubleshooting guide. Symptom cause solution poor airflow • plugged outside hood 1/4 in. (6 mm) mesh. • clean exterior hoods or vents • filters plugged. • remove and clean filter. • core obstructed...

  • Page 14

    Hr150, 200; er150, 200 fresh air ventilation systems 68-0269 14 water in venti- lator bottom • drain pans are plugged. • improper connection of ventilator drain lines. • ensure o-ring on drain nozzle adjusted correctly. • look for kinks in line. • ventilator is not level. • level ventilator. • drain...

  • Page 15: Parts List

    Hr150, 200; er150, 200 fresh air ventilation systems 15 68-0269 parts list hr parts list item number (fig. 13) part number for description hr150b hr200b 1 209746 209746 heat transfer core, aluminum with plastic frame 2 208359 208359 blower motor 3 208504 208508 top blower wheel (clockwise) 4 208505 ...

  • Page 16

    Hr150, 200; er150, 200 fresh air ventilation systems 68-0269 16 er parts list item number see fig. 15 part number for description er150b er200b 1 32002074-001 32002074-001 cross flow enthalpy core 2 208359 208359 blower motor 3 208504 208508 top blower wheel (clockwise) 4 208505 208505 top blower ho...

  • Page 17

    Hr150, 200; er150, 200 fresh air ventilation systems 17 68-0269 accessory items parts list not shown—all models *includes magnehelic pressure gauge and two 6 in. Flow measuring stations. Item number part number description 1 207975 ventilation switch 2 208378 ducting elbow, 4 in., plastic 3 208373 d...

  • Page 18

    Hr150, 200; er150, 200 fresh air ventilation systems 68-0269 18 fig. 12. Hr150 and hr200 (shown with manual control) exploded view of parts keyed to hr parts list. 3 m15511b 1 2 4 5 6 7 25 8 8 12 13 14 15 23 22 24 21 28 16 17 18 19 20 26 27 9 10

  • Page 19

    Hr150, 200; er150, 200 fresh air ventilation systems 19 68-0269 fig. 13. Er150 and er200 (shown with manual control) exploded view of er parts list. 3 m11889a 1 2 4 5 6 7 25 8 8 12 13 14 15 23 22 24 21 28 16 17 18 19 20 26 27 9 10

  • Page 20

    68-0269 g.H. 10-02 www.Honeywell.Com/yourhome automation and control solutions honeywell honeywell limited-honeywell limitée 1985 douglas drive north 35 dynamic drive golden valley, mn 55422 scarborough, ontario m1v 4z9 hr150, 200; er150, 200 fresh air ventilation systems.