    Publication t1-721, revision 3 dated: april 15, 2006 installation and operating manual an 98-440 from tech development model: t100-v t urbo t win engine air starters m ur c al c call murcal to place your order p:(661)272-4700 f:(661)947-7570 www.Murcal.Com e-mail: sales@murcal.Com.

  • Page 2: Tdi T

    Tdi t urbo t win ™ from tech development table of contents section subject page 1.0 general information 1 2.0 orientation of the starter 2 3.0 installing the starter 2 4.0 starter operation 4 5.0 t100-v warranty 6 6.0 troubleshooting guide 7 list of illustrations figure title page 1 direction of rot...

  • Page 3: Tdi T

    Tdi t urbo t win ™ from tech development publication t1-721, rev. 3 page 1 issued april 15, 2006 1.0 general information this manual provides instructions for the installation and operation of the tdi t100-v t urbo t win air starters. If there are questions not answered in this manual, please contac...

  • Page 4: Tdi T

    Tdi t urbo t win ™ from tech development page 2 publication t1-721, rev. 3 issued april 15, 2006 figure 1. Direction of rotation viewed from pinion end. The maximum operating pressure identified on the nameplate is measured at the check port on the starter inlet with the starter in operation. Cautio...

  • Page 5: Tdi T

    Tdi t urbo t win ™ from tech development publication t1-721, rev. 3 page 3 issued april 15, 2006 t100-v starters come standard with a 2" npt female pipe thread for the inlet connection port. The supply line consists of the line from the air source, a pressure regulator (when necessary), a manual or ...

  • Page 6: Tdi T

    Tdi t urbo t win ™ from tech development page 4 publication t1-721, rev. 3 issued april 15, 2006 can be made by increasing the supply pressure. Consult your tdi distributor for advice. Exhaust piping should be routed downward to help prevent any accumulation of condensation in the starter motor. If ...

  • Page 7: Tdi T

    Tdi t urbo t win ™ from tech development publication t1-721, rev. 3 page 5 issued april 15, 2006 incorporate a pressure relief valve set below 600 psig (42 bar) in the supply air line. Note for maximum life of the starter pinion and for the protection of the engine ring gear, limit the operating pre...

  • Page 8: Tdi T

    Tdi t urbo t win ™ from tech development page 6 publication t1-721, rev. 3 issued april 15, 2006 5.0 warranty tdi turbo twin engine starter warranty tech development inc. (tdi) warrants to the original user of the tdi turbo twin ™ model t100-v series air starters to be free from defects in material ...

  • Page 9: Tdi T

    Tdi t urbo t win ™ from tech development publication t1-721, rev. 3 page 7 issued april 15, 2006 6.0 operator’s troubleshooting guide trouble probable cause solution a. Relay valve improperly installed. A. Check typical installation diagram and correct. B. Relay valve not sealing properly. B. Check ...

  • Page 10: Tdi T

    Tdi t urbo t win ™ from tech development page 8 publication t1-721, rev. 3 issued april 15, 2006 figure 2. T100-v t urbo t win air starter with exhaust guard.

  • Page 11: Tdi T

    Tdi t urbo t win ™ from tech development publication t1-721, rev. 3 page 9 issued april 15, 2006 figure 3. T100-v t urbo t win air starter with flanged exhaust elbow.

  • Page 12: Tdi T

    Tdi t urbo t win ™ from tech development page 10 publication t1-721, rev. 3 issued april 15, 2006 figure 4. T100-v t urbo t win air starter installation drawing.

  • Page 13: Tdi T

    Tdi t urbo t win ™ from tech development publication t1-721, rev. 3 page 11 issued april 15, 2006 figure 5. T100-v t urbo t win air starter installation drawing (multiple starters).

  • Page 14: Tdi T

    Tdi t urbo ™ from tech development t win page 12 publication t1-721, rev. 3 issued april 15, 2006 0 50 100 150 200 250 300 350 400 0 1,000 2,000 3,000 4,000 5,000 pinion speed (rpm) 0 10 20 30 40 50 60 70 80 90 psig 60 psig 40 psig .Ft hp model: t121-v performance curve 21 nozzles, compressed air, 9...