TDK-Lambada HD?HWS-P User Manual

Manual is about: AC-DC Switching Power Supply

Summary of HD?HWS-P

  • Page 1

    Hws series ac-dc switching power supply hws・hws/me・hws/hd・hws-p.

  • Page 2: ■

    Environmental-friendly user-friendly safety ● green power line ● complies with rohs directive ● energy saving ● miniature package ● unified style ● extensive product line ● high reliability design ● safety-oriented design ● safe to operate hws series line up ■ hws series model name hws *** - ** ** ou...

  • Page 3: Hws

    Exhaust type forced air cooling using built-in fans installed at the rear of the unit (300w - 1800w ) no space is required at the side between power supplies when multiple units are used. Built-in automated speed control fan contribute to low acoustic noise during normal temperature operation. Unifie...

  • Page 4: Hws/me

    Hws/me hws/hd line up p31 line up p51 ● immunity (all models) attention: please read the instruction manual carefully before using this product. On top of the following condition, please refer to to "hws series" standard instruction manual (p25-). Please confirm whether there is insulation materials ...

  • Page 5: Hws

    Hws-p support drive load with 3 times of peak power ac/dc switching power supply with peak power capability factory machiney textile machinery, cash dispenser main applications line up p69 low acoustic noise with automated speed control fan high power in compact size up to 3 times of peak current hi...

  • Page 6: Contents

    6 ・all specifications are subject to change without notice. Hws 7 specifications hws15 8 hws30 10 hws50 12 hws80 14 hws100 16 hws150 18 hws300 20 hws600 22 hws1000 24 hws1500 26 hws1800t 28 hws/hd 31 specifications hws30/hd 32 hws50/hd 34 hws100/hd 36 hws150/hd 38 hws300/hd 40 hws600/hd 42 hws1000/hd ...

  • Page 7: Hws

    7 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p ● environmentally-friendly: conforming to rohs direc- tives. High-efficiency technology reduces power loss by heat generation. Fan stopping in power-off by external control reduces acoustic noise a...

  • Page 8: Hws15 Specifications

    8 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p items/units model hws15-3 hws15-5 hws15-12 hws15-15 hws15-24 hws15-48 input voltage range (*2) v ac85 - 265 or dc120 - 370 frequency (*2) hz 47 - 63 efficiency (100/200vac)(typ) (*1) % 68 / 71 77 /...

  • Page 9: Hws

    9 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p 【hws15】 d (max) t (max) qty (max) 6.8mm 0.8mm 2 pcs d t voltage adjustment cover (option) (without cover) (with cover) name plate 2-m3 embossed, tapped and countersuck holes screw penetration depth...

  • Page 10: Hws30 Specifications

    10 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p please refer to "tdk-lambda emc filters" catalog. ●recommended emc filter rsel-2001w (*1) at 100/200vac, ta=25 ℃ and maximum output power. (*2) for cases where conformance to various safety specs ...

  • Page 11: Output Derating

    11 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p 【hws30】 voltage adjustment led name plate see note a unit cover (option) (without cover) (with cover) recommended solderless terminal qty (max) 2 pcs 2-m3 embossed, tapped and countersuck holes sc...

  • Page 12: Hws50 Specifications

    12 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p (*1) at 100/200vac, ta=25 ℃ and maximum output power. (*2) for cases where conformance to various safety specs (ul, csa, en) are required, to be described as 100 - 240vac (50/60hz). (*3) not appli...

  • Page 13: Hws

    13 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p 【hws50】 voltage adjustment led cover (option) remote on/off control connector (see note a) 2-m3 tapped holes screw penetration depth max. 6mm 2-m3 embossed, tapped and countersunk holes name plate...

  • Page 14: Hws80 Specifications

    14 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p hws80 specifications (read instruction manual carefully, before using the power supply unit.) items/units model hws80-3 hws80-5 hws80-12 hws80-15 hws80-24 hws80-48 input voltage range (*2) v ac85 ...

  • Page 15: Hws

    15 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p 【hws80】 name plate screw penetration depth max. 6mm unit:mm voltage adjustment led cover (option) (with cover) (without cover) recommended solderless terminal qty (max) 2 pcs 1 pc 2 pcs others ter...

  • Page 16: Hws

    16 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p items/units model hws100-3 hws100-5 hws100-12 hws100-15 hws100-24 hws100-48 input voltage range (*2) v ac85 - 265 or dc120 - 370 frequency (*2) hz 47 - 63 power factor (100/200vac)(typ) (*1) 0.98 ...

  • Page 17: Hws

    17 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p 【hws100】 voltage adjustment cover (option) led (without cover) (with cover) name plate unit recommended solderless terminal qty (max) 2 pcs 1 pc 2 pcs others terminal screw penetration depth max. ...

  • Page 18: Hws

    18 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p (*1) at 100/200vac, ta=25 ℃ and maximum output power. (*2) for cases where conformance to various safety specs (ul, csa, en) are required, to be described as 100 - 240vac (50/60hz). (*3) not appli...

  • Page 19: Hws

    19 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p 【hws150】 terminal d (max) t (max) qty (max) +v / −v 8.1mm 0.8mm 2 pcs 1.0mm 1 pc others 6.8mm 0.8mm 2 pcs d t voltage adjustment led cover (option) name plate unit: mm (without cover) (with cover)...

  • Page 20: Hws

    20 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p items/units model hws300-3 hws300-5 hws300-12 hws300-15 hws300-24 hws300-48 input voltage range (*2) v ac85 - 265 or dc120 - 330 frequency (*2) hz 47 - 63 power factor (100/200vac)(typ) (*1) 0.99 ...

  • Page 21: Hws

    21 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p [un i t : mm] air flow fan 105±0.5 120±0.5 25 22 max 18 max 5 max 165±1 25 61±1 3-m4 4-m4 name plate (14.6) (46.9) 8 2±1 60 ± 0.5 40 ± 0.5 10.5 11 (66.6) (34.5) 11 11 14 (47) (9.5) 10 10 15 7.2 (1...

  • Page 22: Hws

    22 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p (*1) at 100/200vac, ta=25 ℃ and maximum output power. (*2) for cases where conformance to various safety specs (ul, csa, en) are required, to be described as 100 - 240vac (50/60hz). (*3) not appli...

  • Page 23: Hws

    23 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p 8-m4 tapped holes screw penetration depth max. 6mm 8-m4 tapped holes screw penetration depth max. 6mm air flow name plate == accessories == *cover for barrier terminal strip -----1 (attached on te...

  • Page 24: Hws

    24 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p items/units model hws1000 -3 hws1000 -5 hws1000 -6 hws1000 -7 hws1000 -12 hws1000 -15 hws1000 -24 hws1000 -36 hws1000 -48 hws1000 -60 input voltage range (*2) v ac85 - 265 or dc120 - 330 frequency...

  • Page 25: Hws

    25 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p air flow [unit: mm] [chassis material:spcc-sd] 4−m4 4−m4 220±0.5 10 36max 25±1 20max 4max 10 220±0.5 240±1 10±1 2− φ 9 (11.2) 23.7 ± 1 2 5±1 3 3 (9.1) (73.6) 11 126.5 ± 1 20 22 10 45.4 ± 1 11 11 (...

  • Page 26: Hws

    26 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p items/units model hws1500 -3 hws1500 -5 hws1500 -6 hws1500 -7 hws1500 -12 hws1500 -15 hws1500 -24 hws1500 -36 hws1500 -48 hws1500 -60 input voltage range (*2) v ac85 - 265 or dc120 - 330 frequency...

  • Page 27: Hws

    27 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p 27 82±1 (56.8) (11.2) (23.3) (15.1) 4-m4 output terminal input terminal (9.1) (73.6) 126.5 ± 1 11 11 11 20 10 3 46max 260±0.5 260±0.5 280±1 4max 10 20max 10 22 3 23.7 ± 1 25±1 112 ± 0.5 60 ± 0.5 1...

  • Page 28: Hws

    28 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p (*1) at ta=25 ℃ and maximum output power. (*2) for cases where conformance to various safety specs (ul, csa, en) are required, input voltage range will be 200 - 240vac (50/60hz). (*3) first in-rus...

  • Page 29: Hws

    29 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p 【hws1800t 3v】 mounting a (standard mounting) mounting b mounting C mounting d don't use don't use l1 l2 l3 fg i/o signal connector (see note a) bus bar spacer name plate name plate (black) bus bar...

  • Page 31: Hws/hd

    ■ features ●power supply for harsh environment, heavy industry equipment, etc. ・ guaranteed start-up at ta=-40℃. (*1) ・ internal pcb coating (*2) ・ compliant to mil-std-810f, the standard for the products for military use (vibration resistance /shock resistance). ●environmentally-friendly: conformin...

  • Page 32: Hws30/hd Specifications

    Items/units model hws30-3/hd hws30-5/hd hws30-12/hd hws30-15/hd hws30-24/hd hws30-48/hd input voltage range (*2) v ac85 - 265 or dc120 - 370 frequency (*2) hz 47 - 63 efficiency (100/200vac)(typ) (*1) % 70/73 77/80 81/83 83/86 82/83 current (100/200vac)(typ) (*1) a 0.6/0.3 0.8/0.4 inrush current (ty...

  • Page 33: Hws

    【hws30/hd】 ln fg −v +v (5) 82±0.5 (5.5) 17 8 68 ± 0 .5 (10) 77±0.5 8 19max 95±1 (14) 26.5±1 (17) 8.4 7.3 (10.1) voltage adjustment 5-m3.5 led 82 ± 1 (67.5) 8 name plate 15 ac(l) ac(n) fg −v +v screw penetration depth max. 6mm 2-m3 embossed, tapped and countersunk holes screw penetration depth max. 6...

  • Page 34: Hws

    (*1) output voltage might be unstable when start up at -40 to -10℃ and no load. In that case, apply minimum output current. (*2) at 100/200vac, ta=25℃ and maximum output power. (*3) for cases where conformance to various safety specs (ul, csa, en) are required, to be described as 100 - 240vac (50/60...

  • Page 35: Hws

    【hws50/hd】 n l −v f g +v (14) 26.5±1 (15) 19max 97±0.5 120±1 8 8 68 ± 0 .5 5-m3.5 (17) 8.4 7.3 (10.1) voltage adjustment led 82 ± 1 (67.5) 2-m3 tapped holes screw penetration depth max. 6mm +v ac(n) ac(l) fg −v mounting a (standard mounting) mounting b mounting c mounting d don’ t use ( ) ta(° c) mo...

  • Page 36: Hws

    (*1) output voltage might be unstable when start up at -40 to -10℃ and no load. In that case, apply minimum output current. (*2) at 100/200vac, ta=25℃ and maximum output power. (*3) for cases where conformance to various safety specs (ul, csa, en) are required,to be described as 100 - 240vac (50/60h...

  • Page 37: Hws

    【hws100/hd】 mounting a (standard mounting) mounting b mounting c mounting d don’ t use ta(℃) load(%) −10 to +40 50 60 71 100 100 60 20 100 80 60 20 *cooling : convection cooling mounting a mounting b, c, d 120 100 80 60 40 20 0 0 10 20 30 40 50 60 7071 80 -10 mounting a mounting b,c,d ta(℃) load(%) ...

  • Page 38: Hws

    (*1) output voltage might be unstable when start up at -40 to -10℃ and no load. In that case, apply minimum output current. (*2) at 100/200vac, ta=25℃ and maximum output power. (*3) for cases where conformance to various safety specs (ul, csa, en) are required,to be described as 100 - 240vac (50/60h...

  • Page 39: Hws

    Terminal recommended solderless terminal d (max) t (max) qty (max) +v / −v 8.1mm 0.8mm 2pcs 1.0mm 1pc others 6.8mm 0.8mm 2pcs d t mounting a (standard mounting) mounting b mounting c mounting d don’ t use ta(° c) load(%) −10 to +30 40 50 60 71 100 100 100 60 20 100 100 80 60 20 100 90 80 60 20 *cool...

  • Page 40: Hws300/hd Specifications

    (*1) ( ): peak output current at 200vac. Operaing time at peak output is less than 10sec, duty is less than 35%. (*2) at 100/200vac, ta=25℃ and maximum output power. (*3) for cases where conformance to various safety specs (ul, csa, en) are required, to be described as 100 - 240vac (50/60hz). (*4) n...

  • Page 41: Hws

    【hws300/hd】 [unit:mm] air flow 105±0.5 120±0.5 25 22max 18max 5max 165±1 25 61±1 3-m4 4-m4 (14.6) (46.9) 8 2±1 60 ± 0.5 40 ± 0.5 10.5 11 (66.6) (34.5) 1 1 1 1 14 (47) (9.5) 10 10 15 7.2 (10.7) (8.9) 7.3 name plate screw penetration depth max. 6mm 8-m4 tapped holes (tapped at the bottom chassis fan 8...

  • Page 42: Hws

    (*1) ( ): peak output current at 200vac. Operating time at peak output is less than 10sec, duty is less than 35%. (*2) at 100/200vac, ta=25℃ and maximum output power. (*3) for cases where conformance to various safety specs (ul, csa, en) are required, to be described as 100 - 240vac (50/60hz). (*4) ...

  • Page 43: Hws

    8-m4 tapped holes screw penetration depth max. 6mm 8-m4 tapped holes screw penetration depth max. 6mm air flow == accessories == * cover for barrier terminal strip -----1 (attached on terminal at shipment) * short piece --------------------1 shorting +vm - +s, -vm - -s, cnt tog (attached on cn1 at s...

  • Page 44: Hws

    Please refer to "tdk-lambda emc filters" catalog. ●recommended emc filter rsen-2016 hws 1000/hd items/units model hws1000 -3/hd hws1000 -5/hd hws1000 -6/hd hws1000 -7/hd hws1000 -12/hd hws1000 -15/hd hws1000 -24/hd hws1000 -36/hd hws1000 -48/hd hws1000 -60/hd input voltage range (*2) v ac85 - 265 or...

  • Page 45: Hws

    【hws1000/hd】 100 80 60 40 20 0 -10 0 10 20 30 40 50 60 70 71 80 ta (℃) mounting a (standard mounting) don't use don't use mounting b mounting c mounting d load(%) input 85v input 90v∼ input 85v (3, 5v model) input 90v∼ (3, 5v model) *it cannot be used even the product is flipped vertically. 50 =note...

  • Page 46: Hws1500/hd Specifications

    Items/units model hws1500 -3/hd hws1500 -5/hd hws1500 -6/hd hws1500 -7/hd hws1500 -12/hd hws1500 -15/hd hws1500 -24/hd hws1500 -36/hd hws1500 -48/hd hws1500 -60/hd input voltage range (*2) v ac85 - 265 frequency (*2) hz 47 - 63 power factor (100/230vac)(typ) (*1) 0.98 / 0.94 efficiency (100/200vac)(...

  • Page 47: Output Derating

    120 100 80 60 40 20 0 -50 -40 -30 -20 -10 load (%) ta (℃) 85v 90v∼ 82±1 (56.8) (11.2) (23.3) (15.1) 4-m4 output terminal input terminal (9.1) (73.6) 126.5 ± 1 11 11 11 20 10 3 46max 260±0.5 260±0.5 280±1 4max 10 20max 10 22 3 23 .7±1 25 ± 1 112 ± 0.5 60 ± 0 .5 11 7.25 35±1 4-m4 2 -φ9 45.4 ± 1 20 20±...

  • Page 48: Hws1800T/hd Specifications

    Please refer to page 50 for mil-std mounting please refer to "tdk-lambda emc filters" catalog. ●recommended emc filter rsen-2030 hws1800t/hd specifications (read instruction manual carefully, before using the power supply unit.) hws 1800t/hd items/units model hws1800t -3/hd hws1800t -5/hd hws1800t -...

  • Page 49: Hws

    【hws1800t/hd】 2000 1800 1600 1400 1200 1000 800 600 400 200 0 -10 0 10 20 30 40 50 60 70 71 80 3v 5v 6v∼15V 24v∼60V ta (℃) load (w) =notes= 1) input voltage: not gradual start up. 2) no condensing. 3) output voltage becomes more stable by performing the following. A) electrolytic capacitor is added ...

  • Page 50: Hws

    Specification reference model outline / mounting method (mm) hws1000/hd hws1500/hd hws1800t/hd materials = spcc-sd (t=2.0) when mil vibration(mil-std-810f 514.5 category 4 fi gure 514.5c-1, category 10) & mil shock(mil-std-810f 516.5 procedure i) specifi cation is necessary, mount the power supply usi...

  • Page 51: Hws/me

    51 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p ■ features ●ac-dc switching power supply for medical equipment. ・approval ul60601-1 (see note) ・approval en60601-1 (see note) ・approval csa c22.2 no.601.1-m90 (see note) ●environmentally-friendly:...

  • Page 52: Hws

    52 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p please refer to "tdk-lambda emc filters" catalog. ●recommended emc filter rsel-2001wl (*1) at 100/200vac, ta=25 ℃ and maximum output power. (*2) for cases where conformance to various safety specs...

  • Page 53: Hws

    53 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p 【hws30/me】 ln fg −v +v (5) 82±0.5 (5.5) 17 8 68 ± 0.5 (10) 77±0.5 8 19max 95±1 (14) 26.5±1 (17) 8.4 7.3 (10.1) voltage adjustment 5-m3.5 led 8 2±1 (67.5) 8 name plate see note a 15 ac(l) ac(n) fg ...

  • Page 54: Hws

    54 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p hws 50/me hws50/me specifications (read instruction manual carefully, before using the power supply unit.) items/units model hws50-5/me hws50-12/me hws50-15/me hws50-24/me hws50-48/me input voltag...

  • Page 55: Hws

    55 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p 【hws50/me】 voltage adjustment 2-m3 tapped holes screw penetration depth max. 6mm led name plate 2-m3 embossed, tapped and countersunk holes screw penetration depth max. 6mm recommended solderless ...

  • Page 56: Hws100/me Specifications

    56 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p items/units model hws100-5/me hws100-12/me hws100-15/me hws100-24/me hws100-48/me input voltage range (*2) v ac85 - 265 or dc120 - 370 frequency (*2) hz 47 - 63 power factor (100/200vac)(typ) (*1)...

  • Page 57: Hws

    57 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p n l fg −s −v +s +v 2-m3 embossed, tapped and countersunk holes 2-m3 tapped holes screw penetration depth max. 6mm voltage adjustment name plate led [unit: mm] terminal recommended solderless termi...

  • Page 58: Hws

    58 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p items/units model hws150-5/me hws150-12/me hws150-15/me hws150-24/me hws150-48/me input voltage range (*2) v ac85 - 265 or dc120 - 370 frequency (*2) hz 47 - 63 power factor (100/200vac)(typ) (*1)...

  • Page 59: Hws

    59 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p 【hws150/me】 terminal recommended solderless terminal d (max) t (max) qty (max) +v / −v 8.1mm 0.8mm 2 pcs 1.0mm 1 pc others 6.8mm 0.8mm 2 pcs d t m4 m4 +s +v −v −s f g l n (14.6) 37±1 (17) 135±0.5 ...

  • Page 60: Hws

    60 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p items/units model hws300-12/me hws300-15/me hws300-24/me hws300-48/me input voltage range (*3) v ac85 - 265 or dc120 - 330 frequency (*3) hz 47 - 63 power factor (100/200vac)(typ) (*2) 0.99 / 0.95...

  • Page 61: Hws

    61 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p 【hws300/me】 name plate air flow fan 105±0.5 120±0.5 25 22 max 18 max 5 max 165±1 25 61±1 3-m4 4-m4 (14.6) (46.9) 8 2±1 60 ± 0.5 40 ± 0.5 10.5 11 (66.6) (34.5) 11 11 14 (47) (9.5) 10 10 15 7.2 (10....

  • Page 62: Hws

    62 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p items/units model hws600-5/me hws600-12/me hws600-15/me hws600-24/me hws600-48/me input voltage range (*3) v ac85 - 265 or dc120 - 330 frequency (*3) hz 47 - 63 power factor (100/200vac)(typ) (*2)...

  • Page 63: Hws

    63 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p socket housing terminal pins hand crimping tool phdr-12vs sphd-002t-p0.5(awg28 ∼24) sphd-001t-p0.5(awg26 ∼22) yrs-620(sphd-002t-p0.5) yc-610r(sphd-001t-p0.5) manufact jst jst jst part description ...

  • Page 64: Hws

    64 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p items/units model hws1000-24/me hws1000-36/me hws1000-48/me input voltage range (*2) v ac85 - 265 or dc120 - 330 frequency (*2) hz 47 - 63 power factor (100/200vac)(typ) (*1) 0.98/0.95 efficiency ...

  • Page 65: Hws

    65 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p 220±0.5 240±1 220±0.5 2-Φ9 20 22 45.4 ± 1 10 82±1 126.5 ± 1 (73.6) (15.1) 11 11 11 (9.1) (23.3) (56.8) 20 3 2 5±1 (11.2) 10 3 25±1 10±1 23.7 ± 1 10 36max 60 ± 0.5 11 112 ± 0.5 air flow 4max 20max ...

  • Page 66: Hws

    66 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p items/units model hws1500-24/me hws1500-36/me hws1500-48/me input voltage range (*2) v ac85 - 265 frequency (*2) hz 47 - 63 power factor (100/230vac)(typ) (*1) 0.98 / 0.94 efficiency (100/200vac)(...

  • Page 67: Hws

    67 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p 82±1 (56.8) (11.2) (23.3) (15.1) 4-m4 output terminal input terminal (9.1) (73.6) 126.5 ± 1 11 11 11 20 10 3 46max 260±0.5 260±0.5 280±1 4max 10 20max 10 22 3 23.7 ± 1 25±1 112 ± 0.5 60 ± 0.5 11 7...

  • Page 69: Hws-P

    69 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p (*) (100vin/200vin) hws-p single output 300w ∼ 600w hws 300p − 24 ■ features ● single output pulse power type in wide range input power supply. ● up to 3 times peak current. ● full load (100%) cap...

  • Page 70: Hws

    70 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p items/units model hws300p-24 hws300p-36 hws300p-48 input voltage range (*3) v 85 - 265vac or 120 - 330vdc frequency hz 47 - 63 power factor (100/200vac)(typ) (*2) 0.99/0.93 efficiency (100vac)(typ...

  • Page 71: Hws

    71 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p hws 300p + - - + v.Adj l n on cn1 bar code made in japan hws300p - 24 input : 100-240vac 4.4 a output : 24 v 12.5 a ( 7.7 amax@peak power) 50 / 60hz ( 42 amax@peak power) hws300p - 24 output : 24 ...

  • Page 72: Hws600P Specifications

    72 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p items/units model hws600p-24 hws600p-36 hws600p-48 input voltage range (*3) v 85 - 265vac or 120 - 330vdc frequency hz 47 - 63 power factor (100/200vac)(typ) (*2) 0.99/0.94 efficiency (100vac)(typ...

  • Page 73: Hws

    73 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p hws 600p + + - - 6.Tog 5 7 7.Pf 8.Tog 2.Pc 1 3 4.Nc 5.Cnt 3.Nc 1.Com 4 2 8 6 4-m5 v.Adj cn1 on n l 4 0±0 .5 82 ± 1 (6 3 .9) (4 4. 5) (1 4.6 ) 32. 1 21 60 ± 0 .5 20 5max 110±0.5 20 165±1 120±0.5 25...

  • Page 74: Hws

    74 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p hws 15 - 150 lin e fi lt e r rectifier & fi lt er contr ol c ircu it rectifier & fi lt er swit c h in g c ir c u it in rush current limi t c ir c ui t ocp circuit ovp circuit photo- coupler photo- c...

  • Page 75: Block Diagram

    75 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p block diagram ● circuit topology, switching frequency cascade forward topology 190khz(fixed) pfhc circuit : active filter hws300 : 80khz(fixed), hws600 : 90khz(fixed) ● fuse rating: hws300:10a, hws600...

  • Page 76: Hws

    76 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p hws 1500, 1800t ref reference voltage l n fg inrush current limit circuit line filter rectifier pfhc circuit switching circuit primary circuit secondary circuit rectifier & filter +s output pv pc ...

  • Page 77: Hws

    77 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p hws 300, 600, 1000 【hws300, hws600】 input voltage 0v ovp point (*2) pf monitor point(65 - 80% of nominal voltage) vout 0v h(cnt) l(tog) l(tog) h(pf) output voltage remote on/off control(*1) power ...

  • Page 78: Hws

    78 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p hws 1500t, 1800t sequence time chart 【hws1500】 input voltage 0v vout 0v h l l h output voltage remote on/off control (*1) pf signal (open collector) input on input on ovp act on input on ocp act o...

  • Page 79: Hws

    79 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p hws 15, 30, 50, 80, 100, 150 hws 15 -150 series instruction manual pay attention to all warnings and cautions before using the unit. Incorrect usage could lead to an electric shock, damage to the ...

  • Page 80: Hws

    80 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p hws 15, 30, 50, 80, 100, 150 input voltage range input voltage range is single phase 85-265vac (47-63hz) or 120-370vdc. Input voltage which is out of specifi cation may cause unit damage. For cases...

  • Page 81: Hws

    81 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p hws 15, 30, 50, 80, 100, 150 over voltage protection (ovp) the ovp function (inverter shut down method, manual reset type) is provided. When ovp triggers, the output will be shut down. The input s...

  • Page 82: Hws

    82 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p hws 15, 30, 50, 80, 100, 150 model hws150 amb. Temp. A b c d −10 to +25℃ 100 100 100 100 40℃ 100 76 76 76 50℃ 60 60 60 60 60℃ 20 20 20 20 model hws15 hws30 hws50 hws80, hws100 amb. Temp. A b c d a...

  • Page 83: Hws

    83 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p hws 15, 30, 50, 80, 100, 150 5. Wiring method ● the output load line and input line shall be separated and twisted to improve noise sensitivity. ● the sensing lines shall be twisted and separated ...

  • Page 84: Hws

    84 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p hws 15, 30, 50, 80, 100, 150 7. Before concluding that the unit is at fault… before concluding that the unit is at fault, make the follow- ing checks. ● check if the rated input voltage is connect...

  • Page 85: Hws

    85 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p hws 300, 600 hws300, 600 series instruction manual be sure to read the following precautions thoroughly before us- ing this power supply unit. Pay attention to all warnings and cautions before usi...

  • Page 86: Hws

    86 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p pin no configuration function 1 + vm +output monitor terminal. Connected to +output terminal in this power supply unit. (+vm terminal can not supply load current.) remote sensing terminal for +out...

  • Page 87: Hws

    87 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p connecting circuit with cn1 or cn2 connector 1 2 3 4 5 6 7 8 9 10 11 12 connecting circuit with cn1 or cn2 connector 1 2 3 pf signal output signal ground 4 5 6 7 8 9 10 11 12 attached connector wh...

  • Page 88: Hws

    88 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p input voltage range input voltage range is single phase 85-265vac (47-63hz) or 120-330vdc. Input voltage, which is out of specifi cation, may cause unit damage. Rated input voltage for safety stand...

  • Page 89: Hws

    89 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p the mode of control cnt level for tog terminal output built-in fan short or l (0v - 0.8v) on rotate open or h (2.4v - 12v) off stop tog cnt sink current:3.5ma relay,transistor ttl,etc. Output ripp...

  • Page 90: Hws

    90 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p hws 300, 600 so, please check the waveform of test voltage. Output voltage external control(pv) output voltage external control function is available as option with model name followed by “/pv”. O...

  • Page 91: Hws

    91 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p hws 300, 600 5. Wiring method (1) the output load line and input line shall be separated to improve noise sensitivity. (2) the sensing lines shall be twisted and separated from the output lines fo...

  • Page 92: Hws

    92 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p hws 300, 600 7. Fan life expectancy the fan-life has limitation. Therefore, periodic maintenance by exchanging the life-expired fan is required for the power supply. The following fi gure shows the...

  • Page 93: Hws

    93 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p hws 1000 hws 1000 series instruction manual be sure to read the following precautions thoroughly before us- ing this power supply unit. Pay attention to all warnings and cautions before using the ...

  • Page 94: Hws

    94 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p hws 1000 cn01, cn02 connector pin configuration and function cn01, cn02 pin confi guration and function are the same. They are connected to each other in this power supply unit. When the pin of cn0...

  • Page 95: Hws

    95 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p 1 3 5 7 9 11 2 4 6 8 10 12 “+” of load “-” of load twist wire 1 3 5 7 9 2 4 6 8 red black brown yellow 11 10 12 attached connector when shipping connecting circuit with cn01 or cn02 connector basi...

  • Page 96: Hws

    96 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p remote on/off control required ① remove standard attached connector, and use the harness made by the customer and connect external signal to be- tween cnt and tog terminal. ② “tog” terminal is gro...

  • Page 97: Hws

    97 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p input voltage range input voltage range is single phase 85−265vac (47− 63hz). Input voltage, which is out of specification, may cause unit damage. Rated input voltage range fix dur- ing safety sta...

  • Page 98: Hws

    98 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p 1)ttl compatible. The maximum input voltage to cnt termi- nal is 12v, and the maximum allowable reverse voltage is -1v. The sink current of cnt terminal is 3.5ma. 2)output on/off control can be en...

  • Page 99: Hws

    99 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p put- cnt・pf : 100ma). The applied voltage must be gradually increased from zero to testing value and then gradually decreased for shut down. When timer is used, the power supply may be dam- aged b...

  • Page 100: Hws

    100 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p 120% of maximum setting value 110% of maximum setting value rated output voltage: 0 variable resistor value for ref-pv(vr1) [Ω] 10000 20000 30000 40000 50000 120% 100% 80% 60% 40% 20% 0% output v...

  • Page 101: Hws

    101 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p 3. Mounting directions output derating mounting directions are as follows. Standard mounting method is (a). Methods (b), (c) and (d) are also possible. Mounting methods besides (a),(b),(c) and (d...

  • Page 102: Hws

    102 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p 5. External fuse rating refer to the following fuse rating when selecting the exter- nal fuses for input line. Surge current flows when line turns on. Use slow-blow fuse or time-lug fuse. Do not ...

  • Page 103: Hws

    103 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p 7. Warranty this product is warranted for a period of 5 years from the date of shipment. As for the breakdown under a normal use during free warrantee term, repair is at free of charge. However, ...

  • Page 104: Hws

    104 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p hws 1500 please pay extra attention to the wiring. Incorrect connection will damage the power supply. ● when connecting input and output wiring, input ac-line should be off . ● input wiring and ou...

  • Page 105: Hws

    105 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p 1 2 3 “+” of output “−” of output 4 5 6 7 8 9 10 11 12 red black yellow brown cn01, cn02 pin confi guration and function are the same. They are connected to each other in this power supply unit. W...

  • Page 106: Hws

    106 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p remote sensing required ① connect “+s” terminal to “+” terminal of load with sensing wire ② connect “-s” terminal to “-” terminal of load with sensing wires. ③ connect “cnt” terminal to “tog” ter...

  • Page 107: Hws

    107 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p hws 1500 input voltage range input voltage range is single phase 85−265vac (47− 63hz). Input voltage, which is out of specification, may cause unit damage. Rated input voltage range fix dur- ing ...

  • Page 108: Hws

    108 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p hws 1500 please be aware that if cnt terminal and tog terminal is short and input voltage is gradually increase, this will trigger the low output voltage detector protection circuit and will resu...

  • Page 109: Hws

    109 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p withstand voltage this series is designed to withstand 3.0kvac between in- put and output, 2.0kvac between input and fg (chassis), 500vac (60v model : 651vac) between output and fg (chassis), and...

  • Page 110: Hws

    110 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p hws 1500 mounting method caution ⑴ this power supply unit is a forced air-cooling system with a built-in fan. ⑵ this power supply has ventilating holes on the front and back panels. Keep these ar...

  • Page 111: Hws

    111 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p hws 1500 5. External fuse rating refer to the following fuse rating when selecting the external fuses for input line. Surge current fl ows when line turns on. Use slow-blow fuse or time-lug fuse. ...

  • Page 112: Hws

    112 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p hws 1500 ask us for replacement of the fan. This will be a charged service. If you are replacing the fan by yourself, note the following. *1. Be careful in handling the fan unit so as not to caus...

  • Page 113: Hws

    113 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p hws 1800t hws 1800t series instruction manual 1. Terminal explanation be sure to read the following precautions thoroughly before us- ing this power supply unit. Pay attention to all warnings and...

  • Page 114: Hws

    114 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p cn01, cn02 connector pin configuration and function function 1 +v 2 +s 3 −v 4 −s 5 pc 6 com 7 pv 8 ref 9 cnt 10 tog 11 pf 12 tog pin no. Configuration 1 3 5 7 9 11 4 2 6 8 10 12 1 3 5 7 9 11 4 2 6...

  • Page 115: Hws

    115 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p fg l3 l2 l1 load + − m8 bolts and nuts for connecting to the load line. (these are not attached to the product.) connector : (jst) s12b-phdss attached connector when shipping ・housing : (jst) phd...

  • Page 116: Hws

    116 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p fg l3 l2 l1 connector : (jst) s12b-phdss remove standard attached connector, and use the harness made by the customer. ・housing : (jst) phdr-12vs ・contact : (jst) sphd-001t-p0.5 (3-7v model) 2−”+...

  • Page 117: Hws

    117 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p hws 1800t input voltage range input voltage range is three phase 170−265vac(47−63hz). Input voltage, which is out of specifi cation, may cause unit damage. Rated input voltage range fi x during saf...

  • Page 118: Hws

    118 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p tog relay transistor ttl, and etc. Sink current : 3.5ma cnt the mode of control cnt level for tog terminal output built-in fan motor short or l(0−0.8v) on rotate open or h(2.4−12v) off stop 1) tt...

  • Page 119: Hws

    119 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p withstand voltage this series is designed to withstand 3.0kvac between input and out- put, 2.0kvac between input and fg (chassis), 500vac (60v model: 651vac) between output and fg (chassis), and ...

  • Page 120: Hws

    120 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p please consider the following characteristic during usage. 120% 100% 80% 60% 40% 20% 0% rated output: voltage output voltage 120% of maximum setting value 110% of maximum setting value 0 10000 20...

  • Page 121: Hws

    121 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p 1000 40 71 −10 load (w) mounting a, b, c, d 20 0 50 60 0 800 600 400 200 3. Mounting directions output derating mounting directions are as follows. Standard mounting method is (a). Methods (b), (...

  • Page 122: Hws

    122 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p hws 1800t 4. Wiring method (1) the output load line and input line shall be separated and twisted to improve noise sensitivity. (2)the sensing lines shall be twisted or shield wire and separated ...

  • Page 123: Hws

    123 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p hws 1800t 7. Warranty this product is warranted for a period of 5 years from the date of shipment. As for the breakdown under a normal use during free warrantee term, repair is at free of charge....

  • Page 124: Hws

    124 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p hws 300p, 600p hws300p-600p series instruction manual 1. Terminal explanation be sure to read this instruction manual thoroughly before using this product. Pay attention to all cautions and warni...

  • Page 125: Hws

    125 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p hws 300p, 600p cn1 connector pin configuration and function pin no.. Configuration function 1 com gnd for pc signals (only as for hws600p. Hws300p is nc.) 2 pc current balance terminal. ( for out...

  • Page 126: Hws

    126 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p hws 300p, 600p 4. Functions and precautions input voltage range input voltage range is single phase 85 - 265vac (47 - 63hz) or 120 - 330vdc. Input voltage, which is out of specifi cation, may caus...

  • Page 127: Hws

    127 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p hws 300p, 600p output ripple & noise the standard specification for maximum ripple value is measured specifi ed measurement circuit (jeita-rc9131a). When load lines are longer, ripple becomes larg...

  • Page 128: Hws

    128 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p isolation test isolation resistance between output and (chassis) shall be more than 100mΩat 500vdc and between output and cnt・pf shall be more than 10mΩ at 100vdc. For safety operation, voltage s...

  • Page 129: Hws

    129 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p some of the withstand voltage tester may generate high voltage at the matching with monolithic ceramic capacitor and may cause the unit damage. So, please check the waveform of test voltage. Outp...

  • Page 130: Hws

    130 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p hws 300p, 600p output derating according to the mounting directions. Recommended standard mounting method is (a). Method (b) is also possible. Refer to the derating below. Hws300p hws600p output ...

  • Page 131: Hws

    131 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p hws 300p, 600p b). Crimping operation the reference value of wire strip is 2.3mm. As wire strip length differs depending on type of wire and crimping method ,decide the best wire strip length con...

  • Page 132: Hws

    132 ・all specifications are subject to change without notice. Instruction manual hws hws hd hws me hws-p hws 300p, 600p 8. Fan life expectancy t h e f a n - l i f e h a s l i m i t a t i o n . T h e r e f o r e , p e r i o d i c maintenance by exchanging the life-expired fan is required for the powe...

  • Page 133: Usage Precautions

    133 usage precautions ・all specifications are subject to change without notice. Warning ● do not modify, disassemble, or open this product. Failure to do so can cause electric shock hazard. Tdk-lambda cannot be held responsible for damage caused by modifications to this product. ● internal voltage ca...