TDK-Lambda DPX Series Product Handbook

Summary of DPX Series

  • Page 1

    Product handbook dpx series general safety instructions: english read safety instructions servicing: these products are not customer serviceable. Tdk-lambda uk ltd. And their authorised agents only are permitted to carry out repairs. Critical components: these products are not authorised for use as ...

  • Page 2: Dpx Series

    Product handbook dpx series hot surface external hot surfaces: in accordance with local regulations for health and safety at work, manufacturers have an obligation to protect service engineers as well as users. In order to comply with this, a label must be fitted to these products which is clearly v...

  • Page 3: Dpx Series

    Product handbook dpx series allgemeine sicherheitsvorschriften: deutsch lesen sie die sicherheitsvorschriften wartung: diese produkte können nicht durch den kunden gewartet werden. Nur tdk-lambda uk ltd. Und deren zugelassene vertriebshändler sind zur durchführung von reparaturen berechtigt. Kritisc...

  • Page 4: Dpx Series

    Product handbook dpx series heisse oberflÄchen Äußere heiße oberflächen: in Übereinstimmung mit den regionalen bestimmungen für gesundheit und sicherheit bei der arbeit ist der hersteller für den schutz von wartungspersonal und benutzern verantwortlich. Um diesen bestimmungen gerecht zu werden, muss...

  • Page 5: Dpx Series

    Product handbook dpx series consignes de sécurité générale: franÇais lire les consignes de securite entretien: ces produits ne peuvent pas être réparés par le client. Seul, tdk-lambda uk ltd et ses agents agréés sont autorisés à effectuer des réparations. Composants critiques: ces produits ne doiven...

  • Page 6: Dpx Series

    Product handbook dpx series surface chaude surfaces chaudes extérieures: conformément aux réglementations locales concernant la santé et la sécurité sur les lieux de travail, les fabricants doivent protéger les techniciens d'entretien et les utilisateurs. Pour cela, une plaque signalétique doit être...

  • Page 7: Dpx Series

    Product handbook dpx series norme generali di sicurezza: italiano si prega di leggere le norme di sicurezza manutenzione: il cliente non può eseguire alcuna manutenzione su questi prodotti. L'esecuzione delle eventuali riparazioni è consentita solo a tdk-lambda uk ltd e ai suoi agenti autorizzati. C...

  • Page 8: Dpx Series

    Product handbook dpx series superficie calda superfici esterne calde: coerentemente con le norme locali in materia di salute & sicurezza professionali, i produttori sono tenuti a salvaguardare i tecnici di manutenzione, e inoltre gli utenti. Per far fronte a tali obblighi, i prodotti devono presenta...

  • Page 9: Dpx Series

    Product handbook dpx series instrucciones generales de seguridad: espaÑol lea las instrucciones de seguridad servicio: estos productos no pueden ser reparados por los clientes. Tdk-lambda uk ltd. Y sus agentes autorizados son los únicos que pueden llevar a cabo las reparaciones. Componentes fundamen...

  • Page 10: Dpx Series

    Product handbook dpx series un fusible interno protege la unidad y este no debe ser nunca reemplazado por el usuario. En caso de existir algún defecto interno, la unidad debe ser enviada a tdk-lambda uk ltd o a uno de sus agentes autorizados. Superficie caliente superficies externas calientes: según...

  • Page 11: Dpx Series

    Product handbook dpx series instruções gerais de segurança: portuguÊs leia as instruÇÕes de seguranÇa manutenção: estes produtos não são podem ser submetidos a manutenção por parte do cliente. Apenas a tdk-lambda uk ltd e os seus agentes autorizados têm permissão para realizar reparações. Componente...

  • Page 12: Dpx Series

    Product handbook dpx series superfÍcie quente superfícies quentes externas: segundo com os regulamentos locais sobre saúde e segurança no local de trabalho, os fabricantes têm a obrigação de proteger os técnicos de manutenção, bem como os utilizadores. De forma a respeitar este regulamento, estes pr...

  • Page 13: Dpx Series

    Product handbook dpx series general safety instructions: a suitable mechanical and fire enclosure must be provided by the end use equipment for mechanical and fire hazard protection. Environmental specifications: description operation storage use indoor - temperature see product data below see produ...

  • Page 14: Dpx Series

    Product handbook dpx series nomenclature: [ dpx models as described below: unit configuration code: dpxa-bcde-f where: a = power rating (15, 20, 30,40 or 60). B = nominal input voltage (12, 24 or 48) c = input range, 2:1 omit designation: (for 12v nom: 9-18vdc, for 24v nom: 18-36vdc and for 48v nom:...

  • Page 15: Dpx Series

    Product handbook dpx series output parameters: dpx models output designation vout ovp s3p3 3.3vdc 3.9vdc s5p1 5.1vdc 6.2vdc s05 5vdc 6.2vdc s12 12vdc 15vdc s15 15vdc 18vdc d05 ±5vdc ±6.2vdc d12 ±12vdc ±15vdc d15 ±15vdc ±18vdc not all outputs are available in all power ranges. For additional output p...

  • Page 16: Dpx Series

    Product handbook dpx series cooling for unit the unit must be mounted on a din rail and must not be inverted, the output connection uppermost. Installation orientation: top the ventilation openings on these products must not be impeded. Ensure that there is at least 50mm spacing between any obstruct...

  • Page 17: Dpx Series

    Product handbook dpx series mechanical drawings: connection via screw terminals, use 14 – 18awg wire terminal function single o/p dual o/p triple o/p 1 (remote on/off) 2 negative input 3 negative input 4 positive input 5 no connection no connection + auxiliary 6 - output - output (aux) common (0v) 7...

  • Page 18: Dpx Series

    Product handbook dpx series.