    Lzs-a1500-3 power supply installation, operation, and maintenance manual im-llzsa1500-33 november 2013 revision f.

  • Page 3

    Revision f : november 2013 3055 del sol blvd • san diego, ca 92154 • 1-800-lambda-4 lzs-a a1500-33 power supply page. 1 table of contents 1) safety and recommended practices 2 1.1 general safety instructions 2 1.2 safety agency approvals 2 2) ratings and specifications 4 3) features 6 4) guide to ap...

  • Page 4

    Lzs-a a1500-33 power supply revision f : november 2013 page. 2 1 safety and recommended practices 1.1 general safety instructions this power supply is a switch mode power supply for use in applications meeting a pollution degree 2 environment. A suitable mechanical and fire enclosure must be provide...

  • Page 5

    3055 del sol blvd • san diego, ca 92154 • 1-800-lambda-4 lzs-a a1500-33 power supply 8. Openings in the product case are designed for ventilation and must not be obstructed when the product is installed and/or operated. 9. Never push objects of any kind into the product through openings in its case ...

  • Page 6

    Lzs-a a1500-33 power supply revision f : november 2013 page. 4 emissions table 1 ac line conducted emissions en55022/en55011 (0.15-30 mhz) class b radiated rf emissions en55022/en55011 30-1000 mhz class b powerline harmonics en61000-3-2 class a limits powerline fluctuation/flicker en61000-3-3 compli...

  • Page 7

    3055 del sol blvd • san diego, ca 92154 • 1-800-lambda-4 lzs-a a1500-33 power supply revision f : november 2013 page. 5 input specifications units lzs-a1500-3 table 3 input voltage range vac input voltage range*** vac 85-265(47-440hz) single phase; derated to 1200w @ 120vac and 1000w @ 85vac vdc 100...

  • Page 8

    Lzs-a a1500-33 power supply revision f : november 2013 page. 6 operating modes table 5 series operation yes (see fig. 7) parallel operation two or more identical units (see fig. 6). (use of d. Con. Terminal 5 will (with current sharing) provide current sharing to within 10% nominal of rated 60°c cur...

  • Page 9

    3055 del sol blvd • san diego, ca 92154 • 1-800-lambda-4 lzs-a a1500-33 power supply revision f : november 2013 page. 7 protection features table 9 output voltage range v 18-29.4v nominal factory set point v 24v overvoltage protection (adjustable) v 20-34v (factory set to 31.0v) overcurrent protecti...

  • Page 10

    Lzs-a a1500-33 power supply revision f : november 2013 page. 8 4. Guide to application 4.1 safety notice dangerous voltages exist in this equipment. Observe the usual safety precautions when operating, wiring, or servicing to reduce the risk of shock or injury. 4.2 input voltage see table 3 on page ...

  • Page 11

    3055 del sol blvd • san diego, ca 92154 • 1-800-lambda-4 lzs-a a1500-33 power supply revision f : november 2013 page. 9 figure 1 - pin assignments for tb201 and chassis mounted “d” connector 5. Figures.

  • Page 12

    Lzs-a a1500-33 power supply revision f : november 2013 page. 10 figure 3 - typical remote sense connection figure 2 - typical local sense connection ls = local sense s = remote sense ls = local sense s = remote sense.

  • Page 13

    3055 del sol blvd • san diego, ca 92154 • 1-800-lambda-4 lzs-a a1500-33 power supply revision f : november 2013 page. 11 figure 5 - remote voltage control with an external programming resistor or voltage source (remote sensing) figure 4 - remote voltage control with an external programming resistor ...

  • Page 14

    Lzs-a a1500-33 power supply revision f : november 2013 page. 12 figure 6 - parallel operation.

  • Page 15

    3055 del sol blvd • san diego, ca 92154 • 1-800-lambda-4 lzs-a a1500-33 power supply revision f : november 2013 page. 13 figure 7 - series operation.

  • Page 16

    Lzs-a a1500-33 power supply revision f : november 2013 page. 14 figure 8 - outline drawing.

  • Page 17

    3055 del sol blvd • san diego, ca 92154 • 1-800-lambda-4 lzs-a a1500-33 power supply revision f : november 2013 page. 15 figure 9 - remote output on/off control figure 10 - input good, inverter good & output good signals.