TE LDM-1000 Operation Manual

Manual is about: LVDT/RVDT Signal Conditioning Module

Summary of LDM-1000

  • Page 1

    Te connectivity sensors /// ldm-1000 operation manual p/n 09290100-000 rev. C 05/2016 page 1 operation manual ldm-1000 lvdt/rvdt signal conditioning module.

  • Page 2

    Ldm-1000 lvdt/rvdt signal conditioning module te connectivity sensors /// ldm-1000 operation manual p/n 09290100-000 rev. C 05/2016 page 2 table of contents 1. Introduction ..................................................................................................................................

  • Page 3

    Ldm-1000 lvdt/rvdt signal conditioning module te connectivity sensors /// ldm-1000 operation manual p/n 09290100-000 rev. C 05/2016 page 3 1. Introduction the ldm-1000 is an extremely versatile lvdt/rvdt (linear or rotary variable differential transformer) signal conditioning module. The module supp...

  • Page 4

    Ldm-1000 lvdt/rvdt signal conditioning module te connectivity sensors /// ldm-1000 operation manual p/n 09290100-000 rev. C 05/2016 page 4 3. Product description dip switches are provided to allow selection of three transducer excitation frequencies (2.5, 5 and 10 khz), two signal bandwidths (250 or...

  • Page 5

    Ldm-1000 lvdt/rvdt signal conditioning module te connectivity sensors /// ldm-1000 operation manual p/n 09290100-000 rev. C 05/2016 page 5 the list below is the minimum information required to perform a successful calibration: recommended lvdt or rvdt excitation frequency (to set the oscillator freq...

  • Page 6

    Ldm-1000 lvdt/rvdt signal conditioning module te connectivity sensors /// ldm-1000 operation manual p/n 09290100-000 rev. C 05/2016 page 6 4. 2. Internal switches there are two internal dip switch sets (sw1 and sw2) on the pc board assembly of the ldm-1000. The tables below explain the switch positi...

  • Page 7

    Ldm-1000 lvdt/rvdt signal conditioning module te connectivity sensors /// ldm-1000 operation manual p/n 09290100-000 rev. C 05/2016 page 7 4. 4. Oscillator ‘sync’ mode the oscillator ‘sync’ mode setting will depend on the number of ldm-1000’s and transducers in your system, and their physical locati...

  • Page 8

    Ldm-1000 lvdt/rvdt signal conditioning module te connectivity sensors /// ldm-1000 operation manual p/n 09290100-000 rev. C 05/2016 page 8 5. Dimensions and wiring terminals.

  • Page 9

    Ldm-1000 lvdt/rvdt signal conditioning module te connectivity sensors /// ldm-1000 operation manual p/n 09290100-000 rev. C 05/2016 page 9 6. Connection diagrams.

  • Page 10

    Ldm-1000 lvdt/rvdt signal conditioning module te connectivity sensors /// ldm-1000 operation manual p/n 09290100-000 rev. C 05/2016 page 10 7. Calibration procedure using the p1 and p2 terminal blocks according to the “connection diagrams” section of this manual, connect the lvdt or rvdt, a dc voltm...

  • Page 11

    Ldm-1000 lvdt/rvdt signal conditioning module te connectivity sensors /// ldm-1000 operation manual p/n 09290100-000 rev. C 05/2016 page 11 north america europe asia measurement specialties, inc., a te connectivity company 1000 lucas way hampton, va 23666 united states phone: +1-800-745-8008 fax: +1...