2.3 SETT ING UP W ITH A D MX512
CONT ROLLER
2.3-1 DM X512 ADDRESSING WITHOUT ID ADDR ESSING
STAG MODE)
(
The figur e above sh ows a simple D MX512
layo ut w ith the s tart ing address of the first
uni t set at 1, w ith th e second set at 12 and
so o n... ( Note that when used in this w ay,
the C H 11 ID functio n must be inac tive (CH 11=0) )
DM X512
CON TR OLL ER
●
●
●
●
●
●
C onne ct the DMX512 controller to the units i n series .
Each u nit has 11 D MX channels so th e D MX Addresses should incr ease by increments of
11 ( e.g . 1,12,23,34... )
T he ID addr es s has no t been set so th er efore when u sing the contro ller CH 11 must
be inactiv e ( C H11=0 ) .
Each D MX Address may be used as many times as r equired.
Any DMX address in t he range fr om 001 to 512 may be used.
It is als o possi ble to deactivate ID address selecting
fr om the
menu.
on the fixture
【
】
【
】
ID OFF
Settings
2.3-2 DM X512 ADDRESSING WITH ID ADDRESS STAG MODE )
(
C onne ct the DMX512 controller to the units i n series
Each u nit has 11 D MX channels so th e D MX Addresses should incr ease by increments of
11 ( e.g . 1,12,23,34... )
Each D MX Address may be used as many times as r equired.
Any DMX address in t he range fr om 001 to 512 may be used.
Each D MX addr ess may carry up to 66 separate ID a ddresses.
should be s et in the menu on each unit in asce nding values
(i .e. 1,2,3...)
ID add resses ar e accessible fr om Ch 9 on the DMX512 controller.
●
●
●
●
●
●
●
●
【
】
【
】
【
】
ID
ID On
Setti ng s
should be set in the
menu on eac h unit.
Exampl e :
5
.... ........
DM X A dd r.1
DM X Add r. 12
DMX Add r.2 3