Theben HTC SendoClic 907 0 690 Operating Instructions Manual - Factory Setting

Summary of SendoClic 907 0 690

  • Page 1

    1103054501 © 10.2010 theben hts art. Nr. 907 0 690 user remote control sendoclic dk d f gb e i nl s n fin bedienungsanleitung 2 notice d'utilisation 22 operating instructions 42 manual de instrucciones 62 istruzioni per l'uso 82 gebruikershandleiding 102 bruksanvisning 122 bruksanvisning 142 käyttöo...

  • Page 2: English

    42 english operating instructions user remote control sendoclic table of contents 1. Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 2. Function and performance characteristics . . . . . . . . . . . . . . . . . . . . . . . . . 43 3. Op...

  • Page 3: 1.  Use

    43 gb thank you for purchasing a theben hts device and putting your trust in us. 1. Use the remote control is exclusively intended for the use as contractually agreed be- tween the manufacturer and the user. Any other use is considered to be unaccept- able. The manufacturer does not accept liability...

  • Page 4: 3.  Operation

    44 3. Operation for channels 1 and 2 together: on switches lighting on off switches lighting off scene 1 calls up scene 1, programming scene 2 calls up scene 2, programming for channels 1 and 2 separately: switching on, increasing light level switching off, decreasing light level on off scene 2 1 ch...

  • Page 5: 3.1 Switching The Lighting

    45 gb ● the detector confirms a valid command with a flicker of the red led for a half seconds. ● an invalid command or an incompatible ir-group-address are indicated by the led briefly lighting up once. ● if the presence detector does not react - this means that the remote control has not been adju...

  • Page 6: 3.3 Lighting Scenes

    46 3.3 lighting scenes a „lighting scene“ is the term used to describe a lighting situation in a room. When a scene is called up, both lighting groups change intensity to the predefined values or switche to the preset condition. Sendoclic enables two frequently used lighting scenes to be stored and ...

  • Page 7: Ending A Scene

    47 gb ending a scene automatic switching off of lighting using the presence detector when the room is unoccupied or manual switching off using sendoclic ends the lighting scene. Automatic operation is reactivated. Presence detectors with dimming and switching functionality ● automatic switching off ...

  • Page 8: 4.  Lighting Groups

    48 the following operations should only be carried out by a qualified electrician or the technical support service: 4. Lighting groups there are often several lighting groups in one room. Up to two lighting groups can be allocated to sendoclic's two channels. This allows two neighbouring lighting gr...

  • Page 9

    49 gb on off scene 2 1 a a i i i i i i planocentro 101-a-230v planocentro 101-a-230v on off scene 2 1 a a b i i i i i i i planocentro a-knx planocentro a-knx ir-group-address ir-group-address channel channel 2 channel 1.

  • Page 10: Factory Setting

    50 factory setting the sendoclic channels are set to the ir-group-address i + i i (coding switch position 2) on delivery. The factory setting of the presence detector can be found in the relevant operating instructions. When is adjustment required? In some cases this setting has to be changed: ● com...

  • Page 11

    51 gb 5.2 programming ir-group-addresses in the presence detector three different ir-group-addresses are available: ( i , i i , i i i ). Presence detector channel a is programmed via channel 1 on the sendoclic, see table below. Presence detector channel b is programmed via channel 2 on the sendoclic...

  • Page 12: Examples

    52 examples if the coding switch is set, for example, to position 1, both presence detector chan- nels (a + b) are allocated to ir-group-address i. With this program setting, both sendoclic channels switch both channels on a presence detector. If the coding switch is in position 2 ( i + i i ) , the ...

  • Page 13: Ending The Program Mode

    53 gb in order to prevent inadvertent programming of neighbouring presence detectors, the output is reduced in programming mode. The remote control should be pointed at the desired detector from a short distance. After pressing the program button, the remote control remains in program mode for 20 se...

  • Page 14: Procedure:

    54 coding switch channel 1 / channel 2 / buttons scene 1 and 2 0 all all all 1 i i i 2 i i i i + i i 3 i i i i i + i i i 4 i i i i + i i 5 i i i i i i 6 i i i i i i i + i i i 7 i i i i i + i i i 8 i i i i i i i + i i i 9 i i i i i i i i i procedure: set the coding switch (see table below) in the w...

  • Page 15: Situation 1

    55 gb 5.5 examples of programmed ir-group-addresses situation 1 in an office with two presence detectors (each with one lighting group) a remote control has an unwanted affect on the neighbouring lighting group. Solution in the first presence detector, channel a and sendoclic 1 are ir-group-address ...

  • Page 16: Situation 2

    56 situation 2 two lighting groups in an office are to be dimmed separately via a user remote control. Solution in first presence detector, channel a is allocated to ir-group-address i. In the other presence detector, channel a is allocated to ir-group-address i i. Master w i lux master on procedure...

  • Page 17: 6.  Technical Data

    57 gb sendoclic user remote control supply voltage batteries 2 x 1.5v type lr03 / aaa transmission medium infrared range approx. 10 m emission angle ± 15º dimensions 120 x 57 x 24 mm ambient temperature 0º to 50º c colour light grey item no. Sendoclic user remote control 907 0 690 6. Technical data ...

  • Page 18: 7.  Guarantee

    58 7. Guarantee theben hts devices are manufactured and quality-tested with the utmost care using state-of-the-art tech- nologies. Theben hts therefore guarantees perfect function, provided the detectors are used as intended. However, should a defect occur, theben hts offers the following warranty w...

  • Page 19: 8.  Troubleshooting

    59 gb 8. Troubleshooting fault cause detector does not respond to the remote control battery discharged. The battery must be replaced; distance between remote control and detector too great. Remote must be pointed directly at the detector; channel incorrectly set; detector cannot operate with the re...

  • Page 20

    60 theben ag hohenbergstrasse 32, de-72401 haigerloch tel. +49 (0) 74 74 692 - 0 fax +49 (0) 74 74 692 - 150 hotline tel. +49 (0) 74 74 692 - 369 fax +49 (0) 74 74 692 - 207 hotline@theben.De switzerland theben hts ag im langhag 11, ch - 8307 effretikon tel. +41 (0)52 355 17 00 fax +41 (0)52 355 17 ...