Therma-Stor 4036000 Owner's Manual

Manual is about: Phoenix Dry Max LGR Dehumidifier

Summary of 4036000

  • Page 1

    Owner’s manual — phoenix dry max lgr dehumidifier installation, operation & service instructions 1 www.Usephoenix.Com • sales@usephoenix.Com toll-free 1-800-533-7533 read and save these instructions the phoenix dry max lgr dehumidifier • lgr capacity - removes moisture even in dry conditions for dee...

  • Page 2: 1 Safety Certifications

    2 www.Usephoenix.Com • sales@usephoenix.Com toll-free 1-800-533-7533 table of contents introduction ............................................................................1 1. Safety certifications .......................................................2 2. Specifications .........................

  • Page 3

    3 www.Usephoenix.Com • sales@usephoenix.Com toll-free 1-800-533-7533 3.2 electrical requirements the phoenix dry max plugs into a common grounded outlet on a 15 amp circuit. It draws 5.7 amps at 80°f, 60% rh. If used in a wet area, a ground fault interrupter (gfi) is required. If an extension cord i...

  • Page 4

    4 www.Usephoenix.Com • sales@usephoenix.Com toll-free 1-800-533-7533 press the next button to advance to the next screen. If humidistat mode is enabled, then proceed to humidistat set point. Else, proceed to humidity units. Light bar = on the light bar colors and animations will persist while in set...

  • Page 5

    5 www.Usephoenix.Com • sales@usephoenix.Com toll-free 1-800-533-7533 3.3.13 about this device the following information is displayed on the about this device screen: device id hardware version firmware version press the next button to advance to the next screen. Light bar = on the light bar colors a...

  • Page 6

    3.3.20 diagnostic mode - refrig. Test the display will communicate to the user the following information during a refrigeration test: inlet = temperature and rh/grains outlet = temperature and rh/ grains hours = life hours only. Evaporator coil = temperature countdown timer = 20 minutes once the 20 ...

  • Page 7: 4 Maintenance

    7 www.Usephoenix.Com • sales@usephoenix.Com toll-free 1-800-533-7533 the default shut-down time is three minutes plus 20 seconds for a final purge. The shutdown time can be changed be scrolling through the menu to this screen. 3.8 purge button during normal operation the pump automatically cycles wh...

  • Page 8

    8 www.Usephoenix.Com • sales@usephoenix.Com toll-free 1-800-533-7533 no dehumidification, air mover runs but compressor does not. 1. Bad connection in compressor circuit 2. Safety float switch closed, check pump reservoir 3. Defective compressor capacitor 4. Defective compressor overload 5. Defectiv...

  • Page 9: 6 Options & Accessories

    9 www.Usephoenix.Com • sales@usephoenix.Com toll-free 1-800-533-7533 5.6 float switch the float safety switch activates the pump when the water rises too high in the condensate reservoir. The float switch also turns off the compressor until the water level lowers and disengages the switch. To replac...

  • Page 10: 8 Service Parts

    8 service parts specifications subject to change without notice. 10 www.Usephoenix.Com • sales@usephoenix.Com toll-free 1-800-533-7533 part number item description 4036959-01 condensate pump 4024916 condensate hose 4034374 float switch 4035852 compressor 4036934-01 micro channel condenser 4036848 hu...

  • Page 11

    11 www.Usephoenix.Com • sales@usephoenix.Com toll-free 1-800-533-7533 phoenix dry max dehumidifier limited warranty warrantor: therma-stor llc 4201 lien rd. Madison, wi 53704 telephone: 1-800-533-7533 who is covered: this warranty extends only to the original end-user of the phoenix dry max dehumidi...