Therma-Stor 4037391 Installation, Operation And Maintenance Instructions

Summary of 4037391

  • Page 1

    1-877-420-1330 quest 185 cool installation, operation and maintenance instructions 11 p/n: 4033180 serial no.: install date: sold by: hvac installer: please leave manual for homeowner installation by a hvac professional is recommended installation, operation and maintenance instructions installation...

  • Page 2

    1-877-420-1330 quest 185 cool installation, operation and maintenance instructions 2 www.Questhydro.Com info@questhydro.Com safety instructions .........................................................................................................3 1. Intended application for quest 185 cool dehumi...

  • Page 3

    1-877-420-1330 quest 185 cool installation, operation and maintenance instructions 3 www.Questhydro.Com info@questhydro.Com safety precautions read the installation, operation and maintenance instructions carefully before installing and operating this device. Proper adherence to these instructions i...

  • Page 4

    1-877-420-1330 quest 185 cool installation, operation and maintenance instructions 4 www.Questhydro.Com info@questhydro.Com 1. Intended application for quest 185 cool dehumidifier in order to efficiently control humidity levels, the area in which the dehumidifier is to be operated must be free of wa...

  • Page 5

    1-877-420-1330 quest 185 cool installation, operation and maintenance instructions 5 www.Questhydro.Com info@questhydro.Com 5. Installation 5.1 dehumidifier setup 5.1 a location the quest 185 cool dehumidifier can be installed in a variety of locations to meet the owner’s needs as listed below. In a...

  • Page 6

    1-877-420-1330 quest 185 cool installation, operation and maintenance instructions 6 www.Questhydro.Com info@questhydro.Com the quest 185 cool dehumidifier may be suspended with steel hanger straps or a suitable alternative from structural members, unit must be supported from underneath. Don’t hang ...

  • Page 7

    1-877-420-1330 quest 185 cool installation, operation and maintenance instructions 7 www.Questhydro.Com info@questhydro.Com 5.1 d hanging diagram 5.1 e ducting supply duct kit (p/n 4028607) a factory designed supply duct kit can be purchased to accept 10” ducting to both outlets of the quest 185 coo...

  • Page 8

    1-877-420-1330 quest 185 cool installation, operation and maintenance instructions 8 www.Questhydro.Com info@questhydro.Com • do not use the condensing unit as a bench or table. • do not place the condensing unit where the sound and vibration caused by running the unit will a cause a nuisance. Vibra...

  • Page 9

    1-877-420-1330 quest 185 cool installation, operation and maintenance instructions 9 www.Questhydro.Com info@questhydro.Com 5.3 line set installation the installer must supply a line set (1/4” liquid line, 3/8” gas line) suitable for use with r410a refrigerant to connect the indoor unit to the outdo...

  • Page 10

    1-877-420-1330 quest 185 cool installation, operation and maintenance instructions 10 www.Questhydro.Com info@questhydro.Com when installing the line set: • make sure the lines are suitable for use with r410a. • do not crush the lines and always allow a minimum bend radius of 2 inches. • keep the en...

  • Page 11

    1-877-420-1330 quest 185 cool installation, operation and maintenance instructions 11 www.Questhydro.Com info@questhydro.Com 5.4 brazing the line set warning! Polyol ester (poe) oils used with hfc-410a refrigerant absorb moisture very quickly. It is very important that the refrigerant system be kept...

  • Page 12

    1-877-420-1330 quest 185 cool installation, operation and maintenance instructions 12 www.Questhydro.Com info@questhydro.Com use the following procedure to connect the line set to the dehumidifier: 1. Purge the inert gas from the dehumidifier by removing the rubber plugs in the liquid and gas lines ...

  • Page 13

    1-877-420-1330 quest 185 cool installation, operation and maintenance instructions 13 www.Questhydro.Com info@questhydro.Com 5.5 leak test line set and dehumidifier manifold gage set when checking the system charge, use a manifold gage set that features low loss anti-blow back fittings. Manifold gag...

  • Page 14

    1-877-420-1330 quest 185 cool installation, operation and maintenance instructions 14 www.Questhydro.Com info@questhydro.Com 7. Adjust the dry nitrogen pressure regulator to 150 psig. Open the valve on the high pressure side of the manifold gage set to pressurize the line set and dehumidifier. 8. Cl...

  • Page 15

    1-877-420-1330 quest 185 cool installation, operation and maintenance instructions 15 www.Questhydro.Com info@questhydro.Com 5.7 charging the system the condensing unit is pre-charged with 42 oz. Of hfc-410a refrigerant. The installer will add hfc-410a refrig- erant for the dehumidifier and line set...

  • Page 16

    1-877-420-1330 quest 185 cool installation, operation and maintenance instructions 16 www.Questhydro.Com info@questhydro.Com 8. Close the valve on the gas line stub valve core removal tool. 9. Remove the high and low pressure sides of the manifold gage set from the valve core removal tools. 10. Inst...

  • Page 17

    1-877-420-1330 quest 185 cool installation, operation and maintenance instructions 17 www.Questhydro.Com info@questhydro.Com approximate humidity levels per setting “dry” 20% to 30% relative humidity “normal” 50% relative humidity (recommended) “humid” 80% to 90% relative humidity the dehumidifier w...

  • Page 18

    1-877-420-1330 quest 185 cool installation, operation and maintenance instructions 18 www.Questhydro.Com info@questhydro.Com 6.2 a deh 3000r quest recommends a maximum of 6 dehumidifiers linked together. Note: 22 ga wire needed for sensor contact your dealer or call 1-877-420-1330 to order or go to ...

  • Page 19

    1-877-420-1330 quest 185 cool installation, operation and maintenance instructions 19 www.Questhydro.Com info@questhydro.Com 7.1 standard air filter the quest 185 cool dehumidifier ships with a standard merv 11 efficient pleated fabric filter. This filter should be checked every six months. Operatin...

  • Page 20

    1-877-420-1330 quest 185 cool installation, operation and maintenance instructions 20 www.Questhydro.Com info@questhydro.Com 8.4 service parts list - condensing unit item part no. Description 1 4033211 nut 2 4033212 fan-axial 3 4033213 compressor 4 4033214 capacitor 5 4033216 capacitor-fan motor 6 4...

  • Page 21

    1-877-420-1330 quest 185 cool installation, operation and maintenance instructions 21 www.Questhydro.Com info@questhydro.Com low dehumidification capacity (evaporator is frosted continuously). Dehumidification is being called for. 1. Defrost thermostat loose or defective. 2. Low refrigerant charge. ...

  • Page 22

    1-877-420-1330 quest 185 cool installation, operation and maintenance instructions 22 www.Questhydro.Com info@questhydro.Com troubleshooting procedure for performance related issues. This method of diagnosis is used to function check the internal components in the dehumidifier. This is to be used wh...

  • Page 23

    1-877-420-1330 quest 185 cool installation, operation and maintenance instructions 23 www.Questhydro.Com info@questhydro.Com 4033179 compressor cond. Relay cond. Relay coil 115 vac line neutral blk red brn wht blk brn red wht run cap. Wht blk blk 1 n l l n run cap. Blower 24vac signal from dehu. S c...

  • Page 24

    1-877-420-1330 quest 185 cool installation, operation and maintenance instructions 24 www.Questhydro.Com info@questhydro.Com 10. Optional accessories part no. Description 4028531 deh 3000r control (with remote) 4021475 merv 11 filter (16"x20"x2") 4028614 pump kit 4036685 hang kit.

  • Page 25

    1-877-420-1330 quest 185 cool installation, operation and maintenance instructions 25 www.Questhydro.Com info@questhydro.Com limited warranty. Therma-stor, llc (“therma-stor”) warrants as follows: (i) the quest 185 cool dehumidifier (“product”) will be free of material defects in workmanship or mate...