Therma-Stor HI-E Dry Vehere Owner's Manual

Manual is about: Pool & Spa Humidity Controller

Summary of HI-E Dry Vehere

  • Page 1

    Owner’s manual — hi-e dry vehere installation, operation & service instructions 1 www.Thermastor.Com • sales@thermastor.Com toll-free 1-800-533-7533 read and save these instructions hi-e-dry vehere part number 4030050 the hi-e dry vehere pool & spa humidity controller featuring focus™ technology is ...

  • Page 2: 1 Intended Application

    2 www.Thermastor.Com • sales@thermastor.Com toll-free 1-800-533-7533 1 intended application the intended application for the vehere is as a pool & spa area humidity sensing controller applied either as a free-standing device directly in the pool area or operated remotely to provide dehumidified air ...

  • Page 3

    3 www.Thermastor.Com • sales@thermastor.Com toll-free 1-800-533-7533 2.1 vehere diagram a - air intake b - humidity sensor/control c - filters d - air exhaust e - fan switch f - power cord g - drain hose figure 1: vehere diagram. 36.5” a c c b e d g f 40” 19” vehere pool & spa humidity controller fi...

  • Page 4

    4 www.Thermastor.Com • sales@thermastor.Com toll-free 1-800-533-7533 3.1d in remote area, duct inlet & outlet it is often desirable, to install the vehere in an adjacent equipment room or unfinished area. Air is then transferred between the humid room and the unit via ducting. Remotely mount the veh...

  • Page 5

    5 www.Thermastor.Com • sales@thermastor.Com toll-free 1-800-533-7533 controller if the vehere is to be located in a remote location outside the pool or spa area, mounting of the humidity sensor in the space to be conditioned is necessary. If the humidity sensor is not located in the conditioned spac...

  • Page 6: 4 Operation

    6 www.Thermastor.Com • sales@thermastor.Com toll-free 1-800-533-7533 the following points: the vehere will require a single 12” round or equivalent dedicated return from the pool room. The vehere supply can be dedicated or tapped into a forced air system supply. A check damper should be used at the ...

  • Page 7: 6 Maintenance

    7 www.Thermastor.Com • sales@thermastor.Com toll-free 1-800-533-7533 warning: do not use open combustion heating appliances (unless equipped with power exhaust) in a pool room equipped with exhaust fans. Under certain conditions these exhaust fans may cause the backdrafting of toxic combustion by-pr...

  • Page 8: 8 Vehere Accessories

    8 www.Thermastor.Com • sales@thermastor.Com toll-free 1-800-533-7533 1. Defrost thermostat loose or defective 2. Low refrigerant charge 3. Dirty air filters or airflow restricted. 7.3 refrigerant charging warning: only qualified service people should service this unit. The vehere has a high-pressure...

  • Page 9: 9 Vehere Electrical Wiring

    9 www.Thermastor.Com • sales@thermastor.Com toll-free 1-800-533-7533 9 vehere electrical wiring figure 12: vehere wiring diagram..

  • Page 10

    10 www.Thermastor.Com • sales@thermastor.Com toll-free 1-800-533-7533 service parts list: hi-e dry vehere dehumidifier item part no. Qty. Description 1 4021083 1 blower with capacitor 2 4028249 1 capacitor, run, 50mfd, 370v 3 4021589 2 capillary tubes 4 4023604 4 caster, 2”, plastic, swivel 5 402824...

  • Page 11

    11 www.Thermastor.Com • sales@thermastor.Com toll-free 1-800-533-7533 hi-e dry vehere dehumidifier limited warranty warrantor: therma-stor llc 4201 lien rd madison, wi 53704 telephone: 1-800-533-7533 warranty: this warranty covers the hi-e dry vehere. Year one - 100% parts and labor (all components)...