Therma-Stor Phoenix 200 MAX Owner's Manual

Manual is about: Therma-Stor Products Group Owner's Manual Dehumidifier Phoenix 200 MAX TS-262C

Summary of Phoenix 200 MAX

  • Page 1

    Www.Thermastor.Com • sales@thermastor.Com toll-free 1-800-533-7533 owner’s manual — phoenix 200 max installation, operation & service instructions read and save these instructions phoenix 200 max ts-262c the phoenix 200 max is one of the most effective and versatile drying devices available. The 200...

  • Page 2: 1 Specifications

    2 www.Thermastor.Com • sales@thermastor.Com toll-free 1-800-533-7533 1 specifications part no. 4024920 power 0-20 vac, 7.4 amps; 85 watts water 33 pints/day @ aham (80°f, 60%) removal 240 pints/day @ saturation 30 gal/day maximum @ saturation refrigerant lbs., 4 oz. R-22 charge blower 265 cfm intern...

  • Page 3

    3 www.Thermastor.Com • sales@thermastor.Com toll-free 1-800-533-7533 • the air inlet on top & the side outlet must be at least foot from walls and other obstructions to air flow. • if the humid area is very large, dehumidification can be improved by adding an outlet duct to circulate air to stagnant...

  • Page 4: 3 Maintenance

    4 www.Thermastor.Com • sales@thermastor.Com toll-free 1-800-533-7533 2.10 low pressure control if the low side refrigerant pressure drops to 5 psig, the low pressure control opens and shuts off the compressor and blower. It is an automatically reset control. Its primary function is to prevent damage...

  • Page 5

    5 www.Thermastor.Com • sales@thermastor.Com toll-free 1-800-533-7533 the mixture of gas and liquid refrigerant enter the accumulator after leaving the evaporator coil. The accumulator prevents any liquid refrigerant from reaching the compressor. The compressor evacuates the cool refrigerant gas from...

  • Page 6

    6 www.Thermastor.Com • sales@thermastor.Com toll-free 1-800-533-7533 5. Rotate the blower outlet toward you as you remove it. Use care to avoid hooking wiring, tubing or electrical components. 6. Reassembling with the new blower in the above procedure reversed. 4.6 compressor/capacitor replacement t...

  • Page 7

    7 www.Thermastor.Com • sales@thermastor.Com toll-free 1-800-533-7533 if sludge is evident in the discharge line, it will likely be found in the suction line; this indicates the compressor burned out while running. Sludge and acid have been pumped throughout the system. Several changes of the liquid ...

  • Page 8: 5 Wiring Diagram

    8 www.Thermastor.Com • sales@thermastor.Com toll-free 1-800-533-7533 figure 3: electrical schematic of 200 max 5 wiring diagram.

  • Page 9: 6 Service Parts

    9 www.Thermastor.Com • sales@thermastor.Com toll-free 1-800-533-7533 item part no. Qty. Description 4022254 accumulator 402475 air filter, pleated, 2” x 6” x 20” 65% merv- 2 4024682 air filter, pleated, 2” x 6” x 20” 57% merv-8 (optional) 4022489 air filter, pleated, 4” x 6” x 20” 95% mini-pleat mer...

  • Page 10

    0 www.Thermastor.Com • sales@thermastor.Com toll-free 1-800-533-7533 this page intentionally left blank..

  • Page 11

    Www.Thermastor.Com • sales@thermastor.Com toll-free 1-800-533-7533 phoenix 200 max dehumidifier limited warranty warrantor: therma-stor llc po box 8680 madison, wi 53708 telephone: -800-533-7533 who is covered: this warranty extends only to the original end-user of the phoenix 200 max dehumidifier, ...