  • Page 1

    1 www.Usephoenix.Com • sales@usephoenix.Com toll-free 1-800-533-7533 owner’s manual — phoenix 270htx installation, operation & service instructions read and save these instructions the phoenix 270htx lgr, high capacity dehumidifier phoenix 270htx 4028600 specifications subject to change without noti...

  • Page 2: 1 Specifications

    2 www.Usephoenix.Com • sales@usephoenix.Com toll-free 1-800-533-7533 1 specifications part no. 4028600 power 110-120 vac, 8.9 amps water 161 pints/day @ aham (80°f, 60%) removal refrigerant 2 lbs. 1 oz. R410a charge blower 380 cfm internal condensate pump with 20’ lift, 30’ vinyl hose operating 33°f...

  • Page 3

    3 www.Usephoenix.Com • sales@usephoenix.Com toll-free 1-800-533-7533 2.3 electrical requirements the phoenix 270htx plugs into a common grounded outlet on a 15 amp circuit. It draws 8.9 amps at 80°f, 60% rh. If used in a wet area, a ground fault interrupter (gfi) is required. If an extension cord is...

  • Page 4: 3 Maintenance

    4 www.Usephoenix.Com • sales@usephoenix.Com toll-free 1-800-533-7533 if the evaporator temperature does not reach the desired temperature, the compressor will start after 15 minutes. The system will start a timed defrost cycle. The timed defrost cycle ensures the unit will continue to remove water f...

  • Page 5

    5 www.Usephoenix.Com • sales@usephoenix.Com toll-free 1-800-533-7533 the compressor. The compressor evacuates the cool refrigerant gas from the accumulator and compresses it to a high pressure and temperature to repeat the process. 4.2 troubleshooting no dehumidification, neither hour meter display ...

  • Page 6

    6 www.Usephoenix.Com • sales@usephoenix.Com toll-free 1-800-533-7533 4.3 air mover replacement the blower has a psc motor and internal thermal overload protection. If defective, the complete assembly must be replaced. 1. Unplug power cord 2. Remove the front cover 3. Remove the 5 screws attaching bl...

  • Page 7: 5 Wiring Diagram

    7 www.Usephoenix.Com • sales@usephoenix.Com toll-free 1-800-533-7533 5 wiring diagram 4028595.

  • Page 8: 6 Service Parts

    8 www.Usephoenix.Com • sales@usephoenix.Com toll-free 1-800-533-7533 figure 4 specifications subject to change without notice. 6 service parts item description qty part no. 1 top cover 1 4028583 2 top cover hinge 2 4027267 3 wheel 12” gray 2 4026304 4 cotter pin 3/32” 1 1284404 5 air filter 1.75 x 1...

  • Page 9

    9 www.Usephoenix.Com • sales@usephoenix.Com toll-free 1-800-533-7533 this page intentionally left blank..

  • Page 10

    10 www.Usephoenix.Com • sales@usephoenix.Com toll-free 1-800-533-7533 phoenix 270htx dehumidifier limited warranty warrantor: therma-stor llc 4201 lien rd madison, wi 53704 1-800-533-7533 who is covered: this warranty extends only to the original end-user of the phoenix 270htx dehumidifier, and may ...