Therma-Stor Phoenix R150 LGR Owner's Manual

Summary of Phoenix R150 LGR

  • Page 1

    Owner’s manual — phoenix r150 lgr dehumidifier installation, operation & service instructions 1 www.Usephoenix.Com • sales@usephoenix.Com toll-free 1-800-533-7533 read and save these instructions the phoenix r150 lgr (low grain refrigerant) packs large dehumidifier performance into the smallest, lig...

  • Page 2: 1 Safety Certifications

    2 www.Usephoenix.Com • sales@usephoenix.Com toll-free 1-800-533-7533 table of contents introduction ............................................................................1 1. Safety certifications .......................................................2 2. Specifications .........................

  • Page 3

    3 www.Usephoenix.Com • sales@usephoenix.Com toll-free 1-800-533-7533 3.2 electrical requirements the phoenix r150 plugs into a common grounded outlet on a 15 amp circuit. It draws 5.5 amps at 80°f, 60% rh. If used in a wet area, a ground fault interrupter (gfi) is required. If an extension cord is r...

  • Page 4: 4 Maintenance

    4 www.Usephoenix.Com • sales@usephoenix.Com toll-free 1-800-533-7533 4 maintenance 4.1 air filter the phoenix r150 is equipped with a pleated media air filter that must be checked regularly. The standard filter is a merv- 8 high efficiency filter. Operating the unit with a dirty filter will reduce t...

  • Page 5

    5 www.Usephoenix.Com • sales@usephoenix.Com toll-free 1-800-533-7533 5.2 troubleshooting no dehumidification, neither hour meter display nor compressor run and power button does not turn on. 1. Unit unplugged or no power to outlet 2. Defective control board 3. Loose connection in internal wiring no ...

  • Page 6: 6 Options & Accessories

    6 www.Usephoenix.Com • sales@usephoenix.Com toll-free 1-800-533-7533 5.5 condensate pump the internal condensate pump removes water that collects in the reservoir. To replace the condensate pump: 1. Unplug the unit 2. Remove the front housing 3. Unplug the pump wires from the wire harness 4. Remove ...

  • Page 7: 7 Wiring Diagram

    7 www.Usephoenix.Com • sales@usephoenix.Com toll-free 1-800-533-7533 wht blk-5 grn grn-14 blk-5 grn-13 brn-12 blk-16 wht-2 wht-7 blk-3 grn blu-8 blk-4 blk-11 yel yel blu yel yel-10 red-9 wht-7 blk gry wht-6 control board run cap fan motor pump safety no nc float wht pump fan level switch thermistor ...

  • Page 8: 8 Service Parts

    8 www.Usephoenix.Com • sales@usephoenix.Com toll-free 1-800-533-7533 specifications subject to change without notice. 8 service parts item description qty part no. 1 top cover 1 4031258 2 filter, 12” x 12” x 1” merv 7 1 4026315 3 impeller, air mover 1 4034477 4 evaporator coil 1 4031253 5 condenser ...

  • Page 9

    9 www.Usephoenix.Com • sales@usephoenix.Com toll-free 1-800-533-7533 phoenix r150 dehumidifier limited warranty warrantor: therma-stor llc 4201 lien rd. Madison, wi 53704 telephone: 1-800-533-7533 who is covered: this warranty extends only to the original end-user of the phoenix r150 dehumidifier an...