Therma-Stor Santa-Fe Installation, Operation & Service Instructions

Other manuals for Santa-Fe: Installer's & Owner's Manual

Summary of Santa-Fe

  • Page 1

    Lit. No. Ts-192d-0600 ultra efficient dehumidifier a division of dec international po box 8050, madison, wi 53708 toll free 1-800-533-7533 local 1-608-222-5301 santa fe dehumidifier installation, operation & service instructions table of contents 1. Specifications.......................................

  • Page 2: 2.2 Electrical Requirements

    2 2.1c in remote area, duct inlet & outlet. It is often desirable, especially in pool rooms and finished areas, to install the santa fe in an adjacent equipment room or unfinished area. Air is transferred between the humid room and the unit via ducting. The factory mounted humidity control on the sa...

  • Page 3: 3 Operation

    3 2.4c ducting for fresh air fresh air can be brought into the structure continuously by connecting a duct from outside to the santa fe inlet and by turning on the fan switch. Advantages of this form of ventilation include: 1. Outside air is filtered before entering the building. 2. Outside air will...

  • Page 4: 5 Service

    4 5 service caution: servicing the santa fe with its high pressure refrigerant system and high voltage circuitry presents a health hazard which could result in death, serious bodily injury, and/or property damage. Only qualified service people should service this unit. 5.1 warranty a warranty certif...

  • Page 5: 5.4 Refrigerant Charging

    5 5.4 refrigerant charging if the refrigerant charge is lost due to service or a leak, a new charge must be accurately weighed in. If any of the old charge is left in the system, it must be removed before weighing in the new charge. Refer to the unit nameplate for the correct charge weight and refri...

  • Page 6: 5.7 Humidity Control

    6 the following procedure is effective only if the system is monitored after replacing the compressor to insure that the clean up was complete. 1. This procedure assumes that the previously listed compressor motor circuit tests revealed a shorted or open winding. If so, cautiously smell the refriger...

  • Page 7: 5.9 Condensate Pump

    7 5.9 condensate pump condensate is automatically pumped to a remote location when the water level in the pump's reservoir rises to close the float switch. Figure 2: electrical schematic of the santa fe dehumidifier.

  • Page 8: Service Parts List:

    Service parts list: santa fe dehumidifier item part no. Qty. Description 1 4021818 1 accumulator 2 4021475 1 air filter, pleated, 2” x 16” x 20” 3 4021468 1 air filter, foam element 4 4022037 1 blower w/ capacitor (fasco 7090-1874) 5 4021589 2 capillary tubes, .050" id x 28" long 6 4023474 1 compres...