    For integral blower installations: • requires integral blower: model # vtn600cva • requires round duct size (6" diam.) • requires dedicated branch circuit power supply • 120 volt ac• min. 15 amps., 3 prong receptacle • 60 hz. • see steps 3 and 5 for electrical receptacle and duct outlet location for...

  • Page 2: Safety Instructions

    Safety instructions read and save these instructions a. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-related construction. B . Sufficient air is needed for proper combustion and exhausting of gases t...

  • Page 3

    Figure 1 snorkel filters support leg j-box top cap blower assembly wing nuts introduction general description the complete universal cook‘n‘vent ® system consists of the ventilator intake and a blower. See fig. 1. The blower is either an integral (mounted on the vent intake in the cabinet under the ...

  • Page 4

    Step 1 plan the installation carefully follow the planning procedures listed below. See figure 2. A. Determine whether a remote or integral blower will be used. Remote blower installation requires 5 wires plus a ground wire to run from the cook‘n’vent ® to the blower. B. Make sure adequate cabinet a...

  • Page 5

    Figure 2 • be certain to avoid interference with gas and electric supply to cooktop. • shelving and drawer depths are dependent upon cooktop depth and setback. Page 4 10-3/8" 8-1/16" 12" 11" 11" 10" a b integral remote w/ cvt314 remote w/ cvt7.

  • Page 6

    Figures 3 through 6 are examples of possible ducting figure 3 through wall installation figure 4 integral blower vtn600cva ground 12" min. Wall cap wc8 figure 5 through wall duct installation integral blower vtn600cva blower rotated 90° for side connection through wall installation figure 6 remote b...

  • Page 7

    Page 6.

  • Page 8: Step 2

    Table 2. Duct work installation guidelines • keep duct runs as short and straight as possible. • duct fittings (elbows and transitions) reduce air flow efficiency. • back to back elbows and "s" turns significantly reduces air flow and are not recommended. • a short straight length of duct at the inl...

  • Page 9

    Figure 7 table 3 (in inches) ucv30/36/45 installation dimensions with thermador cooktops table 3 notes * dimension "sb" is the minimum distance from the leading edge of the counter to the leading edge of the cutout. + + dimension "bt" is the thickness of back-splash that provides 1 / 8 " clearance b...

  • Page 10

    I nstallation with other cooktops where specified (see part b) figure 8 34-1/2" - ucv36 ow cw 28-1/2" - ucv30 1/8" od cd sb 2-1/4" bt 43-1/2" - ucv45 the installer will need to have the cooktop installation instructions available to complete the installation. All cooktop dimensions should be verifie...

  • Page 11: Step 3

    Step 3 prepare duct cutouts in cabinet table 4 integral blower vtn600cva c d e f g h ucv30 7-1/2 6 1/4 15-1/2 9 - ucv36 7-1/2 6 1/4 15-1/2 9 - ucv45 7-1/2 6 1/4 15-1/2 9 - remote blower vtr600r or vtr1000q c d e f g h ucv30 7-1/4 6 - 12-1/4 12-1/4 3 ucv36 7-1/4 6 - 12-1/4 12-1/4 3 ucv45 7-1/4 6 - 12...

  • Page 12: Step 6

    Step 6 mount vent & cooktop a. Remove grease filters and any packing materials from inside the intake. B. Set the vent intake into rear of countertop opening. Carefully lower it into position so that the flanges on the rear sides and edges fully support the unit hanging from the countertop. C loosel...

  • Page 13: Step 7

    Step 7 mount integral blower or remote blower transition mount integral blower or remote blower transition integral blower vtn600cva only a. Place blower in front of intake inside of cabinet, take conduit and blower wires and guide them towards the right at the floor of the cabinet. B. On each side ...

  • Page 14: Step 8

    Step 8 verify installation, operation & cooktop alignment before performing this procedure, verify that all packing materials were removed from inside the lower enclosure front and that the grease filters have been properly installed. Refer to the care and use manual for instructions regarding filte...

  • Page 15: Notes

    Notes.

  • Page 16