Triplett WireMaster Mapper Instruction Manual - page 15
15
test signal or alters the characteristics of the signal.
Continuity Testing
The WireMaster Mapper can be used as an audible and visual
Continuity tester. To use this feature, the Clip Lead adaptor is of-
ten used.
Connect the Clip Lead adaptor cable to the BNC on the WireMaster
Mapper. When a circuit with Continuity is connected between the
adaptor’s clip leads, the product’s SHORT / CONTINUITY LED will
light and the beeper will sound.
RJ Connectors / Important Note
The WireMaster Mapper and its Remotes are equipped with ‘slot-
ted’ RJ connectors. While these may look like standard RJ11 con-
nectors, they are a special type that can be plugged into either
RJ11 or RJ45 jacks. If a standard RJ11 connector is plugged into
an RJ45 connector, the RJ45 connector may be permanently dam-
aged. The WireMaster Mapper comes with RJ11 and RJ45 Fe-
male / Female couplers. This allows the slotted RJ connector on
the WireMaster Mapper to be mated with other standard RJ con-
nectors. For example, the slotted RJ connector can be plugged
into one side of the RJ45 coupler (simply align the tab with the
center slot and plug in), and the other side of the RJ45 coupler
connected to an RJ45 plug on a LAN cable. An RJ Remote can be
plugged directly into either an RJ11 or RJ45 jack.